Effects of implant thread geometry on percentage of osseointegration and resistance to reverse torque in the tibia of rabbits.

Jennifer Steigenga1, Khalaf Al-Shammari, Carl Misch, Francisco H Nociti, Hom-Lay Wang.   

Abstract

BACKGROUND: Dental implant thread geometry has been proposed as a potential factor affecting implant stability and the percentage of osseointegration. Therefore, the aim of this prospective, randomized, parallel arm study was to evaluate the effects of dental implant thread design on the quality and percent of osseointegration and resistance to reverse torque in the tibia of rabbits.
METHODS: Seventy-two custom-made, screw-shaped, commercially pure titanium implants (3.25 mm diameter x 7 mm length) were placed in the tibiae of 12 white New Zealand rabbits. Each tibia received three implants of varying thread shapes: one with a V-shaped, one with a reverse buttress, and one with a square thread design. The rabbits were sacrificed following an uneventful healing period of 12 weeks. Implants in the right tibiae underwent histologic and histomorphometric assessments of the bone-to-implant contact (BIC) and the radiographic density of surrounding bone, while implants in the left tibiae were used for reverse-torque testing. Differences between the three thread designs were examined using analysis of variance (ANOVA).
RESULTS: Data showed that the square thread design implants had significantly more BIC and greater reverse-torque measurements compared to the V-shaped and reverse buttress thread designs, while no differences were found in radiographic bone density assessments.
CONCLUSION: These results indicate that the square thread design may be more effective for use in endosseous dental implant systems.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15515339     DOI: 10.1902/jop.2004.75.9.1233

Source DB:  PubMed          Journal:  J Periodontol        ISSN: 0022-3492            Impact factor:   6.993


  14 in total

1.  Biomechanical analysis of alveolar bone stress around implants with different thread designs and pitches in the mandibular molar area.

Authors:  Ting-Hsun Lan; Je-Kang Du; Chin-Yun Pan; Huey-Er Lee; Wei-Hao Chung
Journal:  Clin Oral Investig       Date:  2011-02-08       Impact factor: 3.573

2.  [Influence of thread shapes of custommade root-analogue implants on stress distribution of peri-implant bone: A three-dimensional finite element analysis].

Authors:  C P Lin; S H Lu; J X Zhu; H C Hu; Z G Yue; Z H Tang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2019-12-18

3.  The influence of thread geometry on implant osseointegration under immediate loading: a literature review.

Authors:  Hyo-Sook Ryu; Cheol Namgung; Jong-Ho Lee; Young-Jun Lim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

Review 4.  Relationship between dental implant macro-design and osseointegration: a systematic review.

Authors:  Simone Kreve; Izabela Ferreira; Mariana Lima da Costa Valente; Andréa Cândido Dos Reis
Journal:  Oral Maxillofac Surg       Date:  2022-09-29

5.  Developing a new dental implant design and comparing its biomechanical features with four designs.

Authors:  Mansour Rismanchian; Reza Birang; Mahdi Shahmoradi; Hassan Talebi; Reza Jabar Zare
Journal:  Dent Res J (Isfahan)       Date:  2010

6.  Application of laser-induced bone therapy by carbon dioxide laser irradiation in implant therapy.

Authors:  Takahiro Naka; Satoshi Yokose
Journal:  Int J Dent       Date:  2012-02-06

7.  In vivo comparison between the effects of chemically modified hydrophilic and anodically oxidized titanium surfaces on initial bone healing.

Authors:  Hyo-Jung Lee; Il-Hyung Yang; Seong-Kyun Kim; In-Sung Yeo; Taek-Ka Kwon
Journal:  J Periodontal Implant Sci       Date:  2015-05-15       Impact factor: 2.614

Review 8.  Current trends in dental implants.

Authors:  Laura Gaviria; John Paul Salcido; Teja Guda; Joo L Ong
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2014-04-28

9.  A Patient Specific Biomechanical Analysis of Custom Root Analogue Implant Designs on Alveolar Bone Stress: A Finite Element Study.

Authors:  David Anssari Moin; Bassam Hassan; Daniel Wismeijer
Journal:  Int J Dent       Date:  2016-05-04

10.  Customized SmartPeg for measurement of resonance frequency of mini dental implants.

Authors:  Jagjit Singh Dhaliwal; Rubens F Albuquerque; Ali Fakhry; Sukhbir Kaur; Jocelyne S Feine
Journal:  Int J Implant Dent       Date:  2017-02-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.