Literature DB >> 21031527

Local SAR reduction in parallel excitation based on channel-dependent Tikhonov parameters.

Martijn Anton Cloos1, Michel Luong, Guillaume Ferrand, Alexis Amadon, Denis Le Bihan, Nicolas Boulant.   

Abstract

PURPOSE: To reduce the local specific absorption rate (SAR) obtained with tailored pulses using parallel transmission while obtaining homogenous flip angle distributions.
MATERIALS AND METHODS: Finite-element simulations on a human head model were performed to obtain the individual magnetic and electric field maps for each channel of a parallel transmit array. From those maps, SAR calculations were carried out for "spoke" pulses designed to homogenize the flip angle in an axial slice of a human brain at 7 T. Based on the assumption that the coil element nearest to the maximum local energy deposition is the dominant contributor to the corresponding hot spot, a set of channel-dependent Tikhonov parameters is optimized. Resulting SAR distributions are compared to the ones obtained when using standard pulse design approaches based on a single Tikhonov parameter.
RESULTS: In both the small- and large-tip-angle domain, the simulations show local SAR reductions by over a factor of 2 (4) for a well-centered (off-centered) head model at the expense of roughly 1% increment in flip-angle spread over the slice.
CONCLUSION: Significant SAR reductions can be obtained by optimizing channel-dependent Tikhonov parameters based on the relation between coil elements and SAR hot spot positions.
© 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 21031527     DOI: 10.1002/jmri.22346

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  18 in total

Review 1.  Magnetic resonance imaging at ultrahigh fields.

Authors:  Kamil Ugurbil
Journal:  IEEE Trans Biomed Eng       Date:  2014-03-25       Impact factor: 4.538

Review 2.  RF pulse methods for use with surface coils: Frequency-modulated pulses and parallel transmission.

Authors:  Michael Garwood; Kamil Uğurbil
Journal:  J Magn Reson       Date:  2018-04-26       Impact factor: 2.229

3.  Parallel transmission pulse design with explicit control for the specific absorption rate in the presence of radiofrequency errors.

Authors:  Adrian Martin; Emanuele Schiavi; Yigitcan Eryaman; Joaquin L Herraiz; Borjan Gagoski; Elfar Adalsteinsson; Lawrence L Wald; Bastien Guerin
Journal:  Magn Reson Med       Date:  2015-07-03       Impact factor: 4.668

4.  Real-time assessment of potential peak local specific absorption rate value without phase monitoring: Trigonometric maximization method for worst-case local specific absorption rate determination.

Authors:  Ettore Flavio Meliadò; Alessandro Sbrizzi; Cornelis A T van den Berg; Peter R Luijten; Alexander J E Raaijmakers
Journal:  Magn Reson Med       Date:  2020-12-22       Impact factor: 4.668

5.  First in-vivo human imaging at 10.5T: Imaging the body at 447 MHz.

Authors:  Xiaoxuan He; M Arcan Ertürk; Andrea Grant; Xiaoping Wu; Russell L Lagore; Lance DelaBarre; Yiğitcan Eryaman; Gregor Adriany; Eddie J Auerbach; Pierre-François Van de Moortele; Kâmil Uğurbil; Gregory J Metzger
Journal:  Magn Reson Med       Date:  2019-12-17       Impact factor: 4.668

Review 6.  Imaging at ultrahigh magnetic fields: History, challenges, and solutions.

Authors:  Kamil Uğurbil
Journal:  Neuroimage       Date:  2017-07-08       Impact factor: 6.556

7.  Local SAR management by RF shimming: a simulation study with multiple human body models.

Authors:  Hanno Homann; Ingmar Graesslin; Holger Eggers; Kay Nehrke; Peter Vernickel; Ulrich Katscher; Olaf Dössel; Peter Börnert
Journal:  MAGMA       Date:  2011-09-16       Impact factor: 2.310

8.  Local SAR, global SAR, and power-constrained large-flip-angle pulses with optimal control and virtual observation points.

Authors:  Mads S Vinding; Bastien Guérin; Thomas Vosegaard; Niels Chr Nielsen
Journal:  Magn Reson Med       Date:  2015-12-30       Impact factor: 4.668

9.  Local specific absorption rate (SAR), global SAR, transmitter power, and excitation accuracy trade-offs in low flip-angle parallel transmit pulse design.

Authors:  Bastien Guérin; Matthias Gebhardt; Steven Cauley; Elfar Adalsteinsson; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2013-06-14       Impact factor: 4.668

10.  General design approach and practical realization of decoupling matrices for parallel transmission coils.

Authors:  Zohaib Mahmood; Patrick McDaniel; Bastien Guérin; Boris Keil; Markus Vester; Elfar Adalsteinsson; Lawrence L Wald; Luca Daniel
Journal:  Magn Reson Med       Date:  2015-07-31       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.