Literature DB >> 31844984

Increased constraint of rotating hinge knee prosthesis is associated with poorer clinical outcomes as compared to constrained condylar knee prosthesis in total knee arthroplasty.

Jason Beng Teck Lim1,2, Hee Nee Pang3, Keng Jin Darren Tay3, Shi-Lu Chia3, Ngai Nung Lo3, Seng Jin Yeo3.   

Abstract

The aim of this study was to evaluate whether there are any differences in patient-reported outcome measures between semi-constrained condylar constrained knee (CCK) and fully constrained rotating hinge knee (RHK) prostheses in midterm follow-up. We reviewed prospectively collected data of our hospital arthroplasty registry between 2007 and 2014. Thirty-nine patients were identified to have RHK prosthesis TKA and matched for a number of primary/revision TKA, gender, age, body mass index and pre-operative clinical scores to a control group of 78 patients with CCK TKA. Patient demographics, range of movement, varus/valgus deformity, Short Form 36 (SF-36) scores, Oxford Knee Score (OKS), Knee Society Score (KSS) and patient satisfaction were evaluated. Pre-operatively, the RHK and the control group of CCK had similar demographics, proportion of primary/revision TKA and baseline clinical scores (p > 0.05). At 2-year follow-up, patients with CCK prostheses had significantly better clinical outcomes as compared to patients with RHK prosthesis in terms of KSS functional scores, OKS, SF-36 sub-domains of physical functioning, physical role functioning and physical component score. We conclude that at midterm follow-up of 2 years, the CCK patients as compared to RHK patients reported better clinical and functional outcomes in terms of OKS, KSS functional score and SF-36 with a greater proportion of patients who were satisfied and had their expectations met by surgery. Further biomechanical studies are needed to investigate the association between component constraint and clinical outcomes for these prostheses.

Entities:  

Keywords:  Complications; Constrained condylar knee; Outcomes; Revision total knee arthroplasty; Rotating hinge knee

Mesh:

Year:  2019        PMID: 31844984     DOI: 10.1007/s00590-019-02598-x

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  30 in total

1.  Rotating-hinge total knee for revision total knee arthroplasty.

Authors:  Alessandro Bistolfi; Giuseppe Massazza; Federica Rosso; Maurizio Crova
Journal:  Orthopedics       Date:  2012-03-07       Impact factor: 1.390

2.  Rotating hinged total knee replacement: use with caution.

Authors:  Aidin Eslam Pour; Javad Parvizi; Nicholas Slenker; James J Purtill; Peter F Sharkey
Journal:  J Bone Joint Surg Am       Date:  2007-08       Impact factor: 5.284

Review 3.  Tibiofemoral instability in primary total knee replacement: a review, Part 1: Basic principles and classification.

Authors:  Huseyin S Yercan; Tarik Ait Si Selmi; Tahir S Sugun; Philippe Neyret
Journal:  Knee       Date:  2005-08       Impact factor: 2.199

4.  The role of constraint in total knee arthoplasty.

Authors:  Thomas P Sculco
Journal:  J Arthroplasty       Date:  2006-04-17       Impact factor: 4.757

5.  Why are total knees failing today? Etiology of total knee revision in 2010 and 2011.

Authors:  William C Schroer; Keith R Berend; Adolph V Lombardi; C Lowry Barnes; Michael P Bolognesi; Michael E Berend; Merrill A Ritter; Ryan M Nunley
Journal:  J Arthroplasty       Date:  2013-08-15       Impact factor: 4.757

6.  Reoperation after condylar revision total knee arthroplasty.

Authors:  M J Stuart; J E Larson; B F Morrey
Journal:  Clin Orthop Relat Res       Date:  1993-01       Impact factor: 4.176

7.  Low-dose irradiation and constrained revision for severe, idiopathic, arthrofibrosis following total knee arthroplasty.

Authors:  Yasser R Farid; Rishi Thakral; Henry A Finn
Journal:  J Arthroplasty       Date:  2013-03-22       Impact factor: 4.757

8.  Quality of life and clinical outcome in salvage revision total knee replacement: hinged vs total condylar design.

Authors:  Susanne Fuchs; Christian Sandmann; Georg Gerdemann; Adrian Skwara; Carsten O Tibesku; Friedrich Bottner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-08-21       Impact factor: 4.342

9.  Causes of instability after total knee arthroplasty.

Authors:  Sang Jun Song; Robert C Detch; William J Maloney; Stuart B Goodman; James I Huddleston
Journal:  J Arthroplasty       Date:  2013-07-26       Impact factor: 4.757

10.  Revision Total Knee Arthroplasty for Instability-Outcome for Different Types of Instability and Implants.

Authors:  Jaap S Luttjeboer; Menno R Bénard; Koen C Defoort; Gijs G van Hellemondt; Ate B Wymenga
Journal:  J Arthroplasty       Date:  2016-07-21       Impact factor: 4.757

View more
  2 in total

1.  Indications, clinical outcome and survival of rotating hinge total knee arthroplasty in a retrospective study of 63 primary and revision cases.

Authors:  Andreas Hecker; Hans-Jürg A Pütz; Sebastian Wangler; Sophie C Eberlein; Frank M Klenke
Journal:  Eur J Orthop Surg Traumatol       Date:  2022-08-22

2.  Constraint in complex primary total knee arthroplasty: rotating hinge versus condylar constrained implants.

Authors:  Francesco Castagnini; Barbara Bordini; Monica Cosentino; Cristina Ancarani; Stefano Lucchini; Giovanni Bracci; Francesco Traina
Journal:  Arch Orthop Trauma Surg       Date:  2022-01-27       Impact factor: 2.928

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.