Literature DB >> 31838595

How reliable and accurate is the shade determination of premolars by spectrophotometry?

Anna-Luisa Klotz1, Yasamin Habibi, Alexander Jochen Hassel2, Peter Rammelsberg2, Andreas Zenthöfer2.   

Abstract

OBJECTIVES: To evaluate the reliability and accuracy of spectrophotometric shade determination of premolars and to compare the results with those for incisors.
MATERIAL AND METHODS: Fifty-seven participants with natural maxillary incisors and premolars were recruited to investigate the research question. The colour of test teeth (incisors, n = 210; premolars, n = 192) was measured by use of the Vita Easyshade Advance (ES-A) and Vita Easyshade V (ES-V). Accuracy was evaluated by rating the shade tab matches recommended by the devices (scale, 1 = excellent match to 3 = mismatch). Inter-device reliability between the ES-A and ES-V for measurement of incisors and premolars was evaluated using intra-class correlation coefficients (ICC). The ratings for the accuracy of the devices were analysed using descriptive and bivariate statistics. A linear regression model was used to evaluate possible independent influencing confounders on the shade match.
RESULTS: Inter-device agreement of the ES-A and ES-V for measurement of incisors and premolars was excellent for all colour components (ICC > 0.9). The accuracy of both devices was acceptable to excellent for incisors and premolars, although the ES-V was more accurate than the ES-A (p < 0.001). No significant difference in accuracy was detected between premolars and incisors (p = 0.182). The linear regression model confirmed the bivariate testing.
CONCLUSIONS: The reliability and accuracy of spectrophotometric shade determination seem comparable for incisors and premolars. The recently introduced ES-V seems more accurate than its predecessor model. Further studies are needed to validate the results of this study.

Entities:  

Keywords:  Easyshade; L* a* b*; Premolars; Spectrophotometer; Tooth shade determination

Year:  2019        PMID: 31838595     DOI: 10.1007/s00784-019-03162-x

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  20 in total

1.  Color comparison of two shade guides.

Authors:  Rade D Paravina; John M Powers; Rose-Marie Fay
Journal:  Int J Prosthodont       Date:  2002 Jan-Feb       Impact factor: 1.681

2.  In vivo quantitative evaluation of tooth color with hand-held colorimeter and custom template.

Authors:  Kazuki Shimada; Yoshiyuki Kakehashi; Hideo Matsumura; Naomi Tanoue
Journal:  J Prosthet Dent       Date:  2004-04       Impact factor: 3.426

Review 3.  Dental color matching instruments and systems. Review of clinical and research aspects.

Authors:  Stephen J Chu; Richard D Trushkowsky; Rade D Paravina
Journal:  J Dent       Date:  2010-08-01       Impact factor: 4.379

4.  Shade selection performed by novice dental professionals and colorimeter.

Authors:  E Klemetti; A-M Matela; P Haag; M Kononen
Journal:  J Oral Rehabil       Date:  2006-01       Impact factor: 3.837

5.  Precision of in vivo spectrophotometric colour evaluation of natural teeth.

Authors:  A Karamouzos; M A Papadopoulos; G Kolokithas; A E Athanasiou
Journal:  J Oral Rehabil       Date:  2007-08       Impact factor: 3.837

6.  Reliability and accuracy of four dental shade-matching devices.

Authors:  Seungyee Kim-Pusateri; Jane D Brewer; Elaine L Davis; Alvin G Wee
Journal:  J Prosthet Dent       Date:  2009-03       Impact factor: 3.426

7.  Performance assessment of dental shade guides.

Authors:  Rade D Paravina
Journal:  J Dent       Date:  2009-03-28       Impact factor: 4.379

8.  Comparison of the Easyshade Compact and Advance in vitro and in vivo.

Authors:  Andreas Zenthöfer; Tomas Cabrera; Nicoleta Corcodel; Peter Rammelsberg; Alexander J Hassel
Journal:  Clin Oral Investig       Date:  2013-10-08       Impact factor: 3.573

9.  The repeatability of digital shade measurement--a clinical study.

Authors:  Constanze Olms; Jürgen M Setz
Journal:  Clin Oral Investig       Date:  2012-07-25       Impact factor: 3.573

10.  Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: an in vivo and in vitro study.

Authors:  Hee-Kyung Kim
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

View more
  1 in total

1.  Bleaching efficacy and quality of life of different bleaching techniques - randomized controlled trial.

Authors:  Ruben Pereira; João Silveira; Susana Dias; Ana Cardoso; António Mata; Duarte Marques
Journal:  Clin Oral Investig       Date:  2022-08-17       Impact factor: 3.606

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.