Literature DB >> 31834164

Does An Augmented Reality-based Portable Navigation System Improve the Accuracy of Acetabular Component Orientation During THA? A Randomized Controlled Trial.

Hiroyuki Ogawa1, Kenji Kurosaka1, Atsuko Sato2, Naoyuki Hirasawa1, Masaaki Matsubara2, Sachiyuki Tsukada1.   

Abstract

BACKGROUND: We developed an augmented reality (AR)-based portable navigation system in which the surgeon can view the pelvic plane and placement angle of an acetabular cup on the display of a smartphone during THA. QUESTIONS/PURPOSES: (1) Is acetabular component placement more accurate using the AR-based portable navigation system compared with the conventional freehand technique? (2) Is intraoperative measurement of placement angle more accurate when using the AR-based portable navigation system compared with a goniometer?
METHODS: Forty-six patients were randomly assigned to undergo acetabular cup placement during THA using the AR-based portable navigation system (AR navigation group) or placement of a mechanical alignment guide (conventional group). All surgeries were performed with the patient in the lateral decubitus position. We compared the absolute value of the difference between the targeted placement angle and postoperative measured placement angle between the groups using two types of imaging (radiography and CT).
RESULTS: In terms of radiographic inclination, the mean differences between the targeted placement angle and postoperative measured angle were smaller in the AR navigation group than in the conventional group for both radiographs and CT images (2.3° ± 1.4° versus 3.9° ± 2.4°, respectively; p = 0.009 and 1.9° ± 1.3° versus 3.4° ± 2.6°, respectively; p = 0.02). There were no differences in radiographic anteversion between the two groups. No complications were associated with the use of the AR-based portable navigation system.
CONCLUSIONS: This system yielded no differences in acetabular anteversion accuracy, and no clinically important differences in acetabular inclination. Therefore, at this time we cannot recommend this device as its costs and risks cannot be justified based on the absence of a clinically meaningful difference in cup placement accuracy. Although we detected no complications, this was a small series, and this approach adds both surgical time and pins in the ilium. LEVEL OF EVIDENCE: Level I, therapeutic study.

Entities:  

Mesh:

Year:  2020        PMID: 31834164      PMCID: PMC7170692          DOI: 10.1097/CORR.0000000000001083

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.755


  15 in total

1.  Use of intraoperative X-rays to optimize component position and leg length during total hip arthroplasty.

Authors:  Kace A Ezzet; Julie C McCauley
Journal:  J Arthroplasty       Date:  2013-09-26       Impact factor: 4.757

2.  Computer-Assisted Navigation Is Associated with Reductions in the Rates of Dislocation and Acetabular Component Revision Following Primary Total Hip Arthroplasty.

Authors:  Daniel D Bohl; Michael T Nolte; Kevin Ong; Edmund Lau; Tyler E Calkins; Craig J Della Valle
Journal:  J Bone Joint Surg Am       Date:  2019-02-06       Impact factor: 5.284

3.  Does Intraoperative Fluoroscopy Improve Limb-Length Discrepancy and Acetabular Component Positioning During Direct Anterior Total Hip Arthroplasty?

Authors:  Joshua S Bingham; Mark J Spangehl; Jeremy T Hines; Michael J Taunton; Adam J Schwartz
Journal:  J Arthroplasty       Date:  2018-05-28       Impact factor: 4.757

4.  A Pilot Study of Augmented Reality Technology Applied to the Acetabular Cup Placement During Total Hip Arthroplasty.

Authors:  Hiroyuki Ogawa; Seiichirou Hasegawa; Sachiyuki Tsukada; Masaaki Matsubara
Journal:  J Arthroplasty       Date:  2018-02-05       Impact factor: 4.757

5.  The definition and measurement of acetabular orientation.

Authors:  D W Murray
Journal:  J Bone Joint Surg Br       Date:  1993-03

6.  Accuracy of Cup Positioning With the Computed Tomography-Based Two-dimensional to Three-Dimensional Matched Navigation System: A Prospective, Randomized Controlled Study.

Authors:  Kazuki Yamada; Hirosuke Endo; Tomonori Tetsunaga; Takamasa Miyake; Tomoaki Sanki; Toshifumi Ozaki
Journal:  J Arthroplasty       Date:  2017-08-12       Impact factor: 4.757

7.  Can Augmented Reality Be Helpful in Pelvic Bone Cancer Surgery? An In Vitro Study.

Authors:  Hwan Seong Cho; Min Suk Park; Sanjay Gupta; Ilkyu Han; Han-Soo Kim; Hyunseok Choi; Jaesung Hong
Journal:  Clin Orthop Relat Res       Date:  2018-09       Impact factor: 4.176

8.  Measurements of pelvic flexion angle using three-dimensional computed tomography.

Authors:  Shunsaku Nishihara; Nobuhiko Sugano; Takashi Nishii; Kenji Ohzono; Hideki Yoshikawa
Journal:  Clin Orthop Relat Res       Date:  2003-06       Impact factor: 4.176

9.  Acetabular component orientation in 834 total hip arthroplasties using a manual technique.

Authors:  Yukihide Minoda; Toru Kadowaki; Mitsunari Kim
Journal:  Clin Orthop Relat Res       Date:  2006-04       Impact factor: 4.176

Review 10.  Computer-assisted orthopaedic surgery and robotic surgery in total hip arthroplasty.

Authors:  Nobuhiko Sugano
Journal:  Clin Orthop Surg       Date:  2013-02-20
View more
  6 in total

1.  Prognostic role of affected side of the sacroiliac joint in pain recurrence after total hip arthroplasty with prior manual correction of iliosacral dislocation: prospective randomized clinical study.

Authors:  Lychagin Alexey; Cherepanov Vadim; Lipina Marina; Tselisheva Evgenia; Yurku Kseniya; Yavlieva H Roza; Korkunov Alexey; Vyazankin Ivan
Journal:  Int Orthop       Date:  2021-10-16       Impact factor: 3.075

2.  CORR Insights®: Does An Augmented Reality-based Portable Navigation System Improve the Accuracy of Acetabular Component Orientation During THA? A Randomized Controlled Trial.

Authors:  Brent A Ponce
Journal:  Clin Orthop Relat Res       Date:  2020-05       Impact factor: 4.755

Review 3.  Augmented Reality in Orthopedic Surgery Is Emerging from Proof of Concept Towards Clinical Studies: a Literature Review Explaining the Technology and Current State of the Art.

Authors:  Fabio A Casari; Nassir Navab; Laura A Hruby; Philipp Kriechling; Ricardo Nakamura; Romero Tori; Fátima de Lourdes Dos Santos Nunes; Marcelo C Queiroz; Philipp Fürnstahl; Mazda Farshad
Journal:  Curr Rev Musculoskelet Med       Date:  2021-02-05

4.  Imageless navigation for primary total hip arthroplasty: a meta-analysis study.

Authors:  Filippo Migliorini; Francesco Cuozzo; Francesco Oliva; Joerg Eschweiler; Frank Hildebrand; Nicola Maffulli
Journal:  J Orthop Traumatol       Date:  2022-04-15

5.  Augmented reality-aided unicompartmental knee arthroplasty.

Authors:  Sachiyuki Tsukada; Hiroyuki Ogawa; Kenji Kurosaka; Masayoshi Saito; Masahiro Nishino; Naoyuki Hirasawa
Journal:  J Exp Orthop       Date:  2022-09-05

6.  Augmented Reality-Assisted Femoral Bone Resection in Total Knee Arthroplasty.

Authors:  Sachiyuki Tsukada; Hiroyuki Ogawa; Masahiro Nishino; Kenji Kurosaka; Naoyuki Hirasawa
Journal:  JB JS Open Access       Date:  2021-07-23
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.