Reliability of optical devices for three-dimensional facial anatomy description: a systematic review and meta-analysis.

D Gibelli1, C Dolci1, A Cappella1, C Sforza2.   

Abstract

The use of three-dimensional (3D) optical instruments to measure soft tissue facial characteristics is increasing, but systematic assessments of their reliability, practical use in research and clinics, outcome measurements, and advantages and limitations are not fully established. Therefore, a review of the current literature was performed on the reliability of facial anthropometric measurements obtained by 3D optical facial reproductions as compared to conventional anthropometry or other optical devices. The systematic literature search was conducted in electronic databases following the PRISMA guidelines (PROSPERO registration: CRD42018085473). Overall, 815 studies were identified, with 27 final papers included. Two meta-analyses were conducted. Tested devices included conventional cameras, laser scanning, stereophotogrammetry, and structured light. Studies measured living people or inanimate objects. Overall, the optical devices were considered reliable for the measurement of linear distances. Some caution is needed for surface assessments. All instruments are suitable for the analysis of inanimate objects, but fast scan devices should be preferred for living subjects to avoid motion artefacts in the orbital and nasolabial areas. Prior facial landmarking is suggested to improve measurement accuracy. Practical needs and economic means should direct the choice of the most appropriate instrument. Considering the increasing interest in surface-to-surface measurements, fast scan devices should be preferred, and dedicated protocols devised.
Copyright © 2019 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  face; imaging; lasers; photogrammetry; reliability; three-dimensional

Mesh:

Year:  2019        PMID: 31786104     DOI: 10.1016/j.ijom.2019.10.019

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  9 in total

1.  Accuracy of Portable Face-Scanning Devices for Obtaining Three-Dimensional Face Models: A Systematic Review and Meta-Analysis.

Authors:  Hang-Nga Mai; Jaeil Kim; Youn-Hee Choi; Du-Hyeong Lee
Journal:  Int J Environ Res Public Health       Date:  2020-12-25       Impact factor: 3.390

2.  Reproducibility of 3D scanning in the periorbital region.

Authors:  Maria H J Hollander; Joep Kraeima; Anne M L Meesters; Konstantina Delli; Arjan Vissink; Johan Jansma; Rutger H Schepers
Journal:  Sci Rep       Date:  2021-02-11       Impact factor: 4.379

3.  The Effect of Perioral Scan and Artificial Skin Markers on the Accuracy of Virtual Dentofacial Integration: Stereophotogrammetry Versus Smartphone Three-Dimensional Face-Scanning.

Authors:  Hang-Nga Mai; Du-Hyeong Lee
Journal:  Int J Environ Res Public Health       Date:  2020-12-30       Impact factor: 3.390

4.  Can a spontaneous smile invalidate facial identification by photo-anthropometry?

Authors:  Paulo Henrique Viana Pinto; Caio Henrique Pinke Rodrigues; Juliana Rodrigues Rozatto; Ana Maria Bettoni Rodrigues da Silva; Aline Thais Bruni; Marco Antônio Moreira Rodrigues da Silva; Ricardo Henrique Alves da Silva
Journal:  Imaging Sci Dent       Date:  2021-07-13

5.  A Longitudinal 3D Investigation on Facial Similarity among Two Monozygotic Twins in Their First Childhood: An Application of the 3D-3D Facial Superimposition Technique.

Authors:  Daniele M Gibelli; Annalisa Cappella; Claudia Dolci; Riccardo Rosati; Marzia Bedoni; Chiarella Sforza
Journal:  Children (Basel)       Date:  2022-02-02

6.  Robustness of Distinctive Facial Features in Prader-Willi Syndrome: A Stereophotogrammetric Analysis and Association with Clinical and Biochemical Markers in Adult Individuals.

Authors:  Claudia Dolci; Antonello E Rigamonti; Annalisa Cappella; Daniele M Gibelli; Graziano Grugni; Diana Caroli; Chiarella Sforza; Alessandro Sartorio
Journal:  Biology (Basel)       Date:  2022-07-30

7.  The effect of resting morphological lip shape during lip movement: A three-dimensional motion analysis study.

Authors:  Siti Hajjar Nasir; Hashmat Popat; Stephen Richmond
Journal:  Heliyon       Date:  2020-06-01

8.  Accuracy of Mobile Device-Compatible 3D Scanners for Facial Digitization: Systematic Review and Meta-Analysis.

Authors:  Hang-Nga Mai; Du-Hyeong Lee
Journal:  J Med Internet Res       Date:  2020-10-23       Impact factor: 5.428

9.  Effects of Artificial Extraoral Markers on Accuracy of Three-Dimensional Dentofacial Image Integration: Smartphone Face Scan versus Stereophotogrammetry.

Authors:  Hang-Nga Mai; Du-Hyeong Lee
Journal:  J Pers Med       Date:  2022-03-18
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.