Literature DB >> 3177746

Effects of radiotherapy on mandibular reconstruction plates.

M H Castillo1, T M Button, R Doerr, M I Homs, C W Pruett, J I Pearce.   

Abstract

The radiation dose in the vicinity of metal mandibular implants was measured using lithium fluoride (TLD-100) thermoluminescent dosimeters. Dosimeters were positioned in contact with Vitallium and stainless steel (AO) reconstruction plates. Simple transmission was measured with a solid state detector removed from the implant at a depth of 2.5 cm in a polystyrene phantom. The measurements were made for a 6 mV photon beam from a linear accelerator. At points in front of, but in contact with the metal implants, the dose was greater by 23 percent for Vitallium and 17 percent for stainless steel than that with no implant. At contact behind the implant, the dose was reduced considerably: 14 percent for Vitallium and 13 percent for stainless steel. At remote points behind the implant, the dose was reduced due to attenuation.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3177746     DOI: 10.1016/s0002-9610(88)80287-3

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  7 in total

Review 1.  Gold nanoparticles as novel agents for cancer therapy.

Authors:  S Jain; D G Hirst; J M O'Sullivan
Journal:  Br J Radiol       Date:  2011-10-18       Impact factor: 3.039

2.  Evaluation of cytotoxicity and radiation enhancement using 1.9 nm gold particles: potential application for cancer therapy.

Authors:  K T Butterworth; J A Coulter; S Jain; J Forker; S J McMahon; G Schettino; K M Prise; F J Currell; D G Hirst
Journal:  Nanotechnology       Date:  2010-07-05       Impact factor: 3.874

3.  Fixation of osteochondral fragments in the human knee using Meniscus Arrows.

Authors:  Diederick B Wouters; Johannes G M Burgerhof; Jeff T M de Hosson; Rudolf R M Bos
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-05-13       Impact factor: 4.342

4.  Estimation of dose enhancement to soft tissue due to backscatter radiation near metal interfaces during head and neck radiothearpy - A phantom dosimetric study with radiochromic film.

Authors:  Rajesh Ashok Kinhikar; Chandrashekhar M Tambe; Kalpana Patil; Mahadev Mandavkar; Deepak D Deshpande; Rajendra Gujjalanavar; Prabha Yadav; Ashwini Budrukkar
Journal:  J Med Phys       Date:  2014-01

5.  Studying Effects of Gold Nanoparticle on Dose Enhancement in Megavoltage Radiation.

Authors:  M Khadem Abolfazli; S R Mahdavi; Gh Ataei
Journal:  J Biomed Phys Eng       Date:  2015-12-01

Review 6.  Radiosensitizing high-Z metal nanoparticles for enhanced radiotherapy of glioblastoma multiforme.

Authors:  Jinyeong Choi; Gaeun Kim; Su Bin Cho; Hyung-Jun Im
Journal:  J Nanobiotechnology       Date:  2020-09-03       Impact factor: 10.435

Review 7.  Trends in targeted prostate brachytherapy: from multiparametric MRI to nanomolecular radiosensitizers.

Authors:  Alexandru Mihai Nicolae; Niranjan Venugopal; Ananth Ravi
Journal:  Cancer Nanotechnol       Date:  2016-07-04
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.