Literature DB >> 31768935

Evaluating the effectiveness of a single CT method for attenuation correction in stress-rest myocardial perfusion imaging with thallium-201 chloride SPECT.

Mitsuha Fukami1, Kiyoshi Tamura2, Yuya Nakamura2, Syoichi Nakatsukasa2, Masayuki Sasaki3.   

Abstract

This study aimed to evaluate the effectiveness of a single computed tomography (CT) based attenuation correction method using thallium-201 chloride (201TlCl) in stress-rest myocardial perfusion imaging (MPI). The data of 106 patients who underwent MPI with single photon emission computed tomography (SPECT) using 201TlCl were retrospectively reviewed. MPI SPECT images were reconstructed using stress SPECT and stress CT (SIO), rest SPECT and rest CT (RIO), and rest SPECT and stress CT (RIA). The accuracy of alignment between the SPECT and CT images was evaluated with normalized cross-correlation (NCC) and visual examination. The summed rest score (SRS) was used to evaluate hypoperfusion at rest; washout rate (WO) was used to assess ischemia; and left ventricular ejection fraction (LVEF) was used to evaluate the left ventricle (LV) function. There was no significant difference in NCC and visual evaluation in all three dimensions. The SRS of both RIO and RIA (7.5 ± 7.7 and 7.7 ± 7.6, respectively) did not differ significantly. However, SRSs of RIO and RIA showed a strong correlation (r = 0.98). The WO was 39.0 ± 0.98% for both RIO and RIA, with a strong correlation between the two values (r = 1.00). LVEF was 61.1 ± 17.4% for RIO and 61.3 ± 17.4% for RIA, and a strong correlation was observed between the two values (r = 1.00). In conclusion, the single CT-based attenuation correction method with 201TlCl SPECT has an accuracy equivalent to that of the conventional two CT-based attenuation correction method.

Entities:  

Keywords:  201TlCl; CT attenuation correction; Myocardial perfusion image; SPECT; Summed difference score; Washout rate

Year:  2019        PMID: 31768935     DOI: 10.1007/s12194-019-00540-8

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  20 in total

1.  Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first images.

Authors:  M Bocher; A Balan; Y Krausz; Y Shrem; A Lonn; M Wilk; R Chisin
Journal:  Eur J Nucl Med       Date:  2000-06

2.  Integration of automatically measured transient ischemic dilation ratio into interpretation of adenosine stress myocardial perfusion SPECT for detection of severe and extensive CAD.

Authors:  Aiden Abidov; Jeroen J Bax; Sean W Hayes; Ishac Cohen; Hidetaka Nishina; Shunichi Yoda; Xingping Kang; Fatma Aboul-Enein; James Gerlach; John D Friedman; Rory Hachamovitch; Guido Germano; Daniel S Berman
Journal:  J Nucl Med       Date:  2004-12       Impact factor: 10.057

3.  Is the link between anatomical structure and function equally strong at all cognitive levels of processing?

Authors:  Amir M Tahmasebi; Matthew H Davis; Conor J Wild; Jennifer M Rodd; Hélène Hakyemez; P Abolmaesumi; Ingrid S Johnsrude
Journal:  Cereb Cortex       Date:  2011-09-05       Impact factor: 5.357

4.  Comparison of atlas-based techniques for whole-body bone segmentation.

Authors:  Hossein Arabi; Habib Zaidi
Journal:  Med Image Anal       Date:  2016-11-12       Impact factor: 8.545

Review 5.  Artifacts and pitfalls in myocardial perfusion imaging.

Authors:  Steven Burrell; Anita MacDonald
Journal:  J Nucl Med Technol       Date:  2006-12

6.  Comparison of 64-slice CT with gated SPECT for evaluation of left ventricular function.

Authors:  Tiziano Schepis; Oliver Gaemperli; Pascal Koepfli; Ines Valenta; Klaus Strobel; Andrea Brunner; Sebastian Leschka; Lotus Desbiolles; Lars Husmann; Hatem Alkadhi; Philipp A Kaufmann
Journal:  J Nucl Med       Date:  2006-08       Impact factor: 10.057

7.  How to detect and avoid myocardial perfusion SPECT artifacts.

Authors:  E G DePuey
Journal:  J Nucl Med       Date:  1994-04       Impact factor: 10.057

8.  [The examination of attenuation correction using one computed tomography scan in myocardial perfusion stress-rest single photon emission computed tomography].

Authors:  Makoto Sasaki; Shigeto Kawase; Yoshihiro Miyazaki; Takahiro Fujimoto; Kyouji Higashimura
Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi       Date:  2012

9.  Evaluation of an automatic registration-based algorithm for direct measurement of volume change in tumors.

Authors:  Saradwata Sarkar; Timothy D Johnson; Bing Ma; Thomas L Chenevert; Peyton H Bland; Hyunjin Park; Anne F Schott; Brian D Ross; Charles R Meyer
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-12-14       Impact factor: 7.038

10.  Comparison of the short-term survival benefit associated with revascularization compared with medical therapy in patients with no prior coronary artery disease undergoing stress myocardial perfusion single photon emission computed tomography.

Authors:  Rory Hachamovitch; Sean W Hayes; John D Friedman; Ishac Cohen; Daniel S Berman
Journal:  Circulation       Date:  2003-05-27       Impact factor: 29.690

View more
  1 in total

Review 1.  2022 ASNC/AAPM/SCCT/SNMMI guideline for the use of CT in hybrid nuclear/CT cardiac imaging.

Authors:  Mouaz H Al-Mallah; Timothy M Bateman; Kelley R Branch; Andrew Crean; Eric L Gingold; Randall C Thompson; Sarah E McKenney; Edward J Miller; Venkatesh L Murthy; Koen Nieman; Todd C Villines; Michael V Yester; Andrew J Einstein; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2022-09-02       Impact factor: 3.872

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.