Literature DB >> 8151397

How to detect and avoid myocardial perfusion SPECT artifacts.

E G DePuey1.   

Abstract

Although myocardial perfusion imaging with SPECT is an accurate and reliable diagnostic study, artifacts must be avoided, or detected and corrected, to minimize the rate of false-positive results. Common sources of artifacts are nonuniformity in gamma camera detectors, center of rotation errors, misaligned cameras on multidetector scanner systems, errors in image reconstruction, patient motion, radiotracer uptake in nontarget organs and attenuation. Some of these artifacts can be avoided by quality control of instrumentation and by imaging the patient in a prone rather than supine position to separate radiotracer activity from the target and nontarget organs and to reduce the effect of inferior wall attenuation. Other artifacts can be detected by careful image inspection and corrected by reprocessing. The best way to avoid artifacts is to pay very close attention to the technical factors of image acquisition and processing, and to be aware of attenuation factors.

Entities:  

Mesh:

Year:  1994        PMID: 8151397

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  44 in total

1.  Use of rotating (cine) planar projection images in the interpretation of a tomographic myocardial perfusion study.

Authors:  R C Hendel; R J Gibbons; T M Bateman
Journal:  J Nucl Cardiol       Date:  1999 Mar-Apr       Impact factor: 5.952

2.  Gating of myocardial perfusion imaging for the identification of artifacts: is it useful for experienced physicians?

Authors:  S N Chatziioannou; W H Moore; R D Dhekne; P V Ford
Journal:  Tex Heart Inst J       Date:  2000

3.  Effect of attenuation correction on the interpretation of 99mTc-sestamibi myocardial perfusion scintigraphy: the impact of 1 year's experience.

Authors:  Riemer H J A Slart; Tjin H Que; Dirk J van Veldhuisen; Lieke Poot; Paul K Blanksma; D Albert Piers; Pieter L Jager
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-08-27       Impact factor: 9.236

4.  Procedure guidelines for radionuclide myocardial perfusion imaging.

Authors:  C Anagnostopoulos; M Harbinson; A Kelion; K Kundley; C Y Loong; A Notghi; E Reyes; W Tindale; S R Underwood
Journal:  Heart       Date:  2004-01       Impact factor: 5.994

5.  Improved tolerance to missing data in myocardial perfusion SPET using OSEM reconstruction.

Authors:  R L Hatton; B F Hutton; S Angelides; K K L Choong; G Larcos
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02-03       Impact factor: 9.236

6.  Single photon-emission computed tomography.

Authors:  Thomas A Holly; Brian G Abbott; Mouaz Al-Mallah; Dennis A Calnon; Mylan C Cohen; Frank P DiFilippo; Edward P Ficaro; Michael R Freeman; Robert C Hendel; Diwakar Jain; Scott M Leonard; Kenneth J Nichols; Donna M Polk; Prem Soman
Journal:  J Nucl Cardiol       Date:  2010-10       Impact factor: 5.952

7.  Evaluating the effectiveness of a single CT method for attenuation correction in stress-rest myocardial perfusion imaging with thallium-201 chloride SPECT.

Authors:  Mitsuha Fukami; Kiyoshi Tamura; Yuya Nakamura; Syoichi Nakatsukasa; Masayuki Sasaki
Journal:  Radiol Phys Technol       Date:  2019-11-25

Review 8.  Optimal SPECT processing and display: making bad studies look good to get the right answer.

Authors:  Dalia Y Ibrahim; Frank P DiFilippo; Jeremy E Steed; Manuel D Cerqueira
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

9.  Instrumentation quality assurance and performance.

Authors:  Kenneth J Nichols; Stephen L Bacharach; Steven R Bergmann; S James Cullom; Edward P Ficaro; James R Galt; Gary V Heller; Jonathan Links; Josef Machac
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

10.  Investigation of the physical effects of respiratory motion compensation in a large population of patients undergoing Tc-99m cardiac perfusion SPECT/CT stress imaging.

Authors:  P Hendrik Pretorius; Karen L Johnson; Seth T Dahlberg; Michael A King
Journal:  J Nucl Cardiol       Date:  2017-04-21       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.