Literature DB >> 10901447

Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first images.

M Bocher1, A Balan, Y Krausz, Y Shrem, A Lonn, M Wilk, R Chisin.   

Abstract

Scintigraphic diagnosis, based on functional image interpretation, becomes more accurate and meaningful when supported by corresponding anatomical data. In order to produce anatomical images that are inherently registered with images of emission computerised tomography acquired with a gamma camera, an X-ray transmission system was mounted on the slip-ring gantry of a GEMS Millennium VG gamma camera. The X-ray imaging system is composed of an X-ray tube and a set of detectors located on opposite sides of the gantry rotor that moves around the patient along with the nuclear detectors. A cross-sectional anatomical transmission map is acquired as the system rotates around the patient in a manner similar to a third-generation computerised tomography (CT) system. Following transmission, single-photon emission tomography (SPET) or positron emission tomography (PET) coincidence detection images are acquired and the resultant emission images are thus inherently registered to the anatomical maps. Attenuation correction of the emission images is performed with the same anatomical maps to generate transmission maps. Phantom experiments of system performance and examples of first SPET and coincidence detection patient images are presented. Despite limitations of the system when compared with a state of the art CT scanner, the transmission anatomical maps allow for precise anatomical localisation and for attenuation correction of the emission images.

Entities:  

Mesh:

Year:  2000        PMID: 10901447     DOI: 10.1007/s002590050555

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  39 in total

1.  An imaging co-registration system using novel non-invasive and non-radioactive external markers.

Authors:  Tung-Hsin Wu; Jiunn-Kuen Wang; Jason J S Lee; Ren-Shyan Liu; Wan-Yuo Guo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-04-12       Impact factor: 9.236

2.  The use of combined single photon emission computed tomography and X-ray computed tomography to assess the fate of inhaled aerosol.

Authors:  John Fleming; Joy Conway; Caroline Majoral; Livia Tossici-Bolt; Ira Katz; Georges Caillibotte; Diane Perchet; Marine Pichelin; Bernhard Muellinger; Ted Martonen; Philipp Kroneberg; Gabriela Apiou-Sbirlea
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2010-12-18       Impact factor: 2.849

3.  Evaluating the effectiveness of a single CT method for attenuation correction in stress-rest myocardial perfusion imaging with thallium-201 chloride SPECT.

Authors:  Mitsuha Fukami; Kiyoshi Tamura; Yuya Nakamura; Syoichi Nakatsukasa; Masayuki Sasaki
Journal:  Radiol Phys Technol       Date:  2019-11-25

4.  Hybrid SPECT/CT: a new era for SPECT imaging?

Authors:  Orazio Schillaci
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-05       Impact factor: 9.236

5.  Use of coronary calcium score scans from stand-alone multislice computed tomography for attenuation correction of myocardial perfusion SPECT.

Authors:  Tiziano Schepis; Oliver Gaemperli; Pascal Koepfli; Christine Rüegg; Cyrill Burger; Sebastian Leschka; Lotus Desbiolles; Lars Husmann; Hatem Alkadhi; Philipp A Kaufmann
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-08-04       Impact factor: 9.236

Review 6.  Optimal SPECT processing and display: making bad studies look good to get the right answer.

Authors:  Dalia Y Ibrahim; Frank P DiFilippo; Jeremy E Steed; Manuel D Cerqueira
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

7.  Attenuation correction in cardiac SPECT: the boy who cried wolf?

Authors:  Guido Germano; Piotr J Slomka; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

8.  Development of a cost-effective modular SPECT/CT scanner.

Authors:  Dale L Bailey; Paul J Roach; Elizabeth A Bailey; James Hewlett; Ronnie Keijzers
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-03-20       Impact factor: 9.236

Review 9.  Imaging techniques in nuclear cardiology for the assessment of myocardial viability.

Authors:  Riemer H J A Slart; Jeroen J Bax; Dirk J van Veldhuisen; Ernst E van der Wall; Rudi A J O Dierckx; Pieter L Jager
Journal:  Int J Cardiovasc Imaging       Date:  2005-12-13       Impact factor: 2.357

10.  Optimization-based image reconstruction from sparse-view data in offset-detector CBCT.

Authors:  Junguo Bian; Jiong Wang; Xiao Han; Emil Y Sidky; Lingxiong Shao; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2012-12-21       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.