Abstract

A new nasal sensor has been designed using Polyvinylidene fluoride (PVDF) film using its piezoelectric property to measure nasal patency. The aim of this study is to determine the intra- and intersession reliability of the new PVDF nasal sensor measurement of unilateral and combined nasal parameters in a group of healthy subjects. Two identical nasal sensors: for right nostril (RN) and left nostril (LN) were designed using piezoelectric natured PVDF films. Twenty subjects were studied. To evaluate the repeatability, total three sets of PVDF sensor measurements were recorded, two sets were taken 5 min apart during same session without repositioning the PVDF nasal sensors and two more sets were taken during 1 h apart successively, by repositioning the PVDF nasal sensor. Intraclass correlation coefficients (ICC) of PVDF sensor measurements for intra- and intersession showed a high and greater repeatability over time for all the combined (mean) and unilateral (RN and LN) values. In both healthy and patients, ICC values for both intra- and intersession measurements were ≥ 0.80 confirming strong reliability and also almost all of the coefficients of variation for the same parameters were low (below 10%). PVDF sensor measurements showed good intra- and intersession repeatability and can be recommended for the objective monitoring of nasal patency during diagnosis and follow-up of conditions. © Association of Otolaryngologists of India 2018.

Entities:  

Keywords:  Intra- and intersession repeatability; Nasal patency; PVDF nasal sensor; Reliability

Year:  2018        PMID: 31763271      PMCID: PMC6848573          DOI: 10.1007/s12070-018-1349-9

Source DB:  PubMed          Journal:  Indian J Otolaryngol Head Neck Surg        ISSN: 2231-3796


  13 in total

1.  Reproducibility of acoustic rhinometry and rhinomanometry in normal subjects.

Authors:  P E Silkoff; S Chakravorty; J Chapnik; P Cole; N Zamel
Journal:  Am J Rhinol       Date:  1999 Mar-Apr

2.  Diagnostic tools in Rhinology EAACI position paper.

Authors:  Glenis Scadding; Peter Hellings; Isam Alobid; Claus Bachert; Wytske Fokkens; Roy Gerth van Wijk; Philippe Gevaert; Josep Guilemany; Livije Kalogjera; Valerie Lund; Joaquim Mullol; Giovanni Passalacqua; Elina Toskala; Cornelius van Drunen
Journal:  Clin Transl Allergy       Date:  2011-06-10       Impact factor: 5.871

3.  A comparison of the nasal cross-sectional areas and volumes obtained with acoustic rhinometry and magnetic resonance imaging.

Authors:  J P Corey; A Gungor; R Nelson; J Fredberg; V Lai
Journal:  Otolaryngol Head Neck Surg       Date:  1997-10       Impact factor: 3.497

4.  Acoustic rhinometry: evaluation of nasal cavity geometry by acoustic reflection.

Authors:  O Hilberg; A C Jackson; D L Swift; O F Pedersen
Journal:  J Appl Physiol (1985)       Date:  1989-01

5.  Committee report on standardization of rhinomanometry.

Authors:  E B Kern
Journal:  Rhinology       Date:  1981-12       Impact factor: 3.681

6.  Evaluation of polyvinylidene fluoride nasal sensor to assess deviated nasal septum in comparision with peak nasal inspiratory flow measurements.

Authors:  Roopa G Manjunatha; K Rajanna; D Roy Mahapatra; Surya Prakash
Journal:  Am J Rhinol Allergy       Date:  2014 Jan-Feb       Impact factor: 2.467

7.  Repeatability of peak nasal inspiratory flow measurements and utility for assessing the severity of rhinitis.

Authors:  R Starling-Schwanz; H L Peake; C M Salome; B G Toelle; K W Ng; G B Marks; M L Lean; S J Rimmer
Journal:  Allergy       Date:  2005-06       Impact factor: 13.146

8.  Polyvinylidene fluoride film based nasal sensor to monitor human respiration pattern: an initial clinical study.

Authors:  G Roopa Manjunatha; K Rajanna; D Roy Mahapatra; M M Nayak; Uma Maheswari Krishnaswamy; R Srinivasa
Journal:  J Clin Monit Comput       Date:  2013-06-16       Impact factor: 2.502

9.  Correlation of subjective sensation of nasal patency with nasal inspiratory peak flow rate.

Authors:  J W Fairley; L H Durham; S R Ell
Journal:  Clin Otolaryngol Allied Sci       Date:  1993-02

10.  Intersession repeatability of acoustic rhinometry measurements in healthy volunteers.

Authors:  Mohammed Dhafer Al Ahmari; Jadwiga Anna Wedzicha; John Robert Hurst
Journal:  Clin Exp Otorhinolaryngol       Date:  2012-08-27       Impact factor: 3.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.