Literature DB >> 23771706

Polyvinylidene fluoride film based nasal sensor to monitor human respiration pattern: an initial clinical study.

G Roopa Manjunatha1, K Rajanna, D Roy Mahapatra, M M Nayak, Uma Maheswari Krishnaswamy, R Srinivasa.   

Abstract

Design and development of a piezoelectric polyvinylidene fluoride (PVDF) thin film based nasal sensor to monitor human respiration pattern (RP) from each nostril simultaneously is presented in this paper. Thin film based PVDF nasal sensor is designed in a cantilever beam configuration. Two cantilevers are mounted on a spectacle frame in such a way that the air flow from each nostril impinges on this sensor causing bending of the cantilever beams. Voltage signal produced due to air flow induced dynamic piezoelectric effect produce a respective RP. A group of 23 healthy awake human subjects are studied. The RP in terms of respiratory rate (RR) and Respiratory air-flow changes/alterations obtained from the developed PVDF nasal sensor are compared with RP obtained from respiratory inductance plethysmograph (RIP) device. The mean RR of the developed nasal sensor (19.65 ± 4.1) and the RIP (19.57 ± 4.1) are found to be almost same (difference not significant, p > 0.05) with the correlation coefficient 0.96, p < 0.0001. It was observed that any change/alterations in the pattern of RIP is followed by same amount of change/alterations in the pattern of PVDF nasal sensor with k = 0.815 indicating strong agreement between the PVDF nasal sensor and RIP respiratory air-flow pattern. The developed sensor is simple in design, non-invasive, patient friendly and hence shows promising routine clinical usage. The preliminary result shows that this new method can have various applications in respiratory monitoring and diagnosis.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23771706     DOI: 10.1007/s10877-013-9486-x

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  24 in total

Review 1.  Critical review of non-invasive respiratory monitoring in medical care.

Authors:  M Folke; L Cernerud; M Ekström; B Hök
Journal:  Med Biol Eng Comput       Date:  2003-07       Impact factor: 2.602

2.  Comparison of impedance and inductance ventilation sensors on adults during breathing, motion, and simulated airway obstruction.

Authors:  K P Cohen; W M Ladd; D M Beams; W S Sheers; R G Radwin; W J Tompkins; J G Webster
Journal:  IEEE Trans Biomed Eng       Date:  1997-07       Impact factor: 4.538

3.  Optical aspects of a fibre-optic sensor for respiratory rate monitoring.

Authors:  H Pettersson; E N Stenow; H Cai; P A Oberg
Journal:  Med Biol Eng Comput       Date:  1996-11       Impact factor: 2.602

4.  New noninvasive piezoelectric transducer for recording of respiration, heart rate and body movements.

Authors:  J Siivola
Journal:  Med Biol Eng Comput       Date:  1989-07       Impact factor: 2.602

5.  AURA: a new respiratory monitor.

Authors:  V Kulkarni; A Cyna; J M Hutchison; M E Tunstall; J R Mallard
Journal:  Biomed Sci Instrum       Date:  1990

6.  Electrical impedance pneumography for simple nonrestrictive continuous monitoring of respiratory rate, rhythm and tidal volume for surgical patients.

Authors:  J J Freundlich; J C Erickson
Journal:  Chest       Date:  1974-02       Impact factor: 9.410

Review 7.  Respiratory monitoring in the intensive care unit.

Authors:  M J Tobin
Journal:  Am Rev Respir Dis       Date:  1988-12

8.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

9.  Monitoring of the inspired and end-tidal oxygen, carbon dioxide, and nitrous oxide concentrations: clinical applications during anesthesia and recovery.

Authors:  K Linko; M Paloheimo
Journal:  J Clin Monit       Date:  1989-07

Review 10.  Noninvasive monitoring of respiratory mechanics during sleep.

Authors:  R Farré; J M Montserrat; D Navajas
Journal:  Eur Respir J       Date:  2004-12       Impact factor: 16.671

View more
  6 in total

1.  The Reliability of Polyvinylidene Fluoride Sensor for Intra- and Intersession Measurements.

Authors:  Roopa G Manjunatha; Surya Prakash; Konandur Rajanna
Journal:  Indian J Otolaryngol Head Neck Surg       Date:  2018-04-16

2.  Detection of Low Cardiac Index using a Polyvinylidene Fluoride-Based Wearable Ring and Convolutional Neural Networks.

Authors:  Sardar Ansari; Jessica R Golbus; Mohamad H Tiba; Brendan McCracken; Lu Wang; Keith D Aaronson; Kevin R Ward; Kayvan Najarian; Kenn R Oldham
Journal:  IEEE Sens J       Date:  2020-11-03       Impact factor: 4.325

Review 3.  Recent Developments in Printing Flexible and Wearable Sensing Electronics for Healthcare Applications.

Authors:  Saleem Khan; Shawkat Ali; Amine Bermak
Journal:  Sensors (Basel)       Date:  2019-03-11       Impact factor: 3.576

Review 4.  Wearable Multi-Functional Sensing Technology for Healthcare Smart Detection.

Authors:  Xu Zeng; Hai-Tao Deng; Dan-Liang Wen; Yao-Yao Li; Li Xu; Xiao-Sheng Zhang
Journal:  Micromachines (Basel)       Date:  2022-02-02       Impact factor: 2.891

5.  Estimation of Respiratory Rate from Thermography Using Respiratory Likelihood Index.

Authors:  Yudai Takahashi; Yi Gu; Takaaki Nakada; Ryuzo Abe; Toshiya Nakaguchi
Journal:  Sensors (Basel)       Date:  2021-06-27       Impact factor: 3.576

6.  Piezoelectric sensing: Evaluation for clinical investigation of deviated nasal septum.

Authors:  Roopa G Manjunatha; Konandur Rajanna; Roy D Mahapatra; Srinivas Dorasala
Journal:  Allergy Rhinol (Providence)       Date:  2013
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.