Literature DB >> 31742911

Diagnostic accuracy of a novel cuffless self-blood pressure monitor for atrial fibrillation screening in the elderly.

Konstantinos G Kyriakoulis1, Anastasios Kollias1, Ioannis Anagnostopoulos1, Areti Gravvani1, Petros Kalogeropoulos1,2, Antonios Destounis1, George S Stergiou1.   

Abstract

Blood pressure (BP) monitors equipped with atrial fibrillation (AF) detection algorithm are attractive screening tools for AF in elderly hypertensives. This study assessed the diagnostic accuracy of a novel cuffless pocket-size self-BP monitor (Freescan, Maisense) equipped with an AF detection algorithm, which displays results for the detection of "AF" or "Arrhythmia" during routine BP measurement. Subjects aged >65 years or 60-65 years with hypertension, diabetes, or cardiovascular disease were subjected to BP measurements using the Freescan device with simultaneous continuous Holter electrocardiography (ECG) monitoring. Readings with device notification "Instability" (29%) or "Error" (20%) were discarded. Data from 136 subjects with five valid Freescan BP measurements were analyzed (age 73.8 ± 7.1 years, males 63%, treated hypertensives 88%, AF in ECG 21%). Analysis of 680 Freescan readings vs ECG revealed specificity 99%, sensitivity 67%, and diagnostic accuracy 93% for AF diagnosis. When the "Arrhythmia" notification was considered as AF diagnosis, the sensitivity was improved (93%, 96%, and 93%, respectively). Analysis of AF diagnosis in subjects (diagnosis defined as at least three of five readings indicating "AF" or "Arrhythmia") revealed specificity, sensitivity, and diagnostic accuracy for AF detection at 94%, 100%, and 95%, respectively. These data suggest that the Freescan cuffless device could be used as a useful screening tool for AF detection during routine self-measurement of BP in the elderly.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  atrial fibrillation; automated; blood pressure measurement; cuffless; screening

Mesh:

Substances:

Year:  2019        PMID: 31742911      PMCID: PMC8030495          DOI: 10.1111/jch.13730

Source DB:  PubMed          Journal:  J Clin Hypertens (Greenwich)        ISSN: 1524-6175            Impact factor:   3.738


  10 in total

1.  Atrial Fibrillation Detection During 24-Hour Ambulatory Blood Pressure Monitoring: Comparison With 24-Hour Electrocardiography.

Authors:  Anastasios Kollias; Antonios Destounis; Petros Kalogeropoulos; Konstantinos G Kyriakoulis; Angeliki Ntineri; George S Stergiou
Journal:  Hypertension       Date:  2018-05-07       Impact factor: 10.190

2.  A novel cuffless device for self-measurement of blood pressure: concept, performance and clinical validation.

Authors:  N Boubouchairopoulou; A Kollias; B Chiu; B Chen; S Lagou; P Anestis; G S Stergiou
Journal:  J Hum Hypertens       Date:  2017-01-26       Impact factor: 3.012

Review 3.  Requirements for Minimum Sample Size for Sensitivity and Specificity Analysis.

Authors:  Mohamad Adam Bujang; Tassha Hilda Adnan
Journal:  J Clin Diagn Res       Date:  2016-10-01

4.  2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS.

Authors:  Paulus Kirchhof; Stefano Benussi; Dipak Kotecha; Anders Ahlsson; Dan Atar; Barbara Casadei; Manuel Castella; Hans-Christoph Diener; Hein Heidbuchel; Jeroen Hendriks; Gerhard Hindricks; Antonis S Manolis; Jonas Oldgren; Bogdan Alexandru Popescu; Ulrich Schotten; Bart Van Putte; Panagiotis Vardas
Journal:  Eur Heart J       Date:  2016-08-27       Impact factor: 29.983

Review 5.  Hypertension and atrial fibrillation: diagnostic approach, prevention and treatment. Position paper of the Working Group 'Hypertension Arrhythmias and Thrombosis' of the European Society of Hypertension.

Authors:  Athanasios J Manolis; Enrico Agabiti Rosei; Antonio Coca; Renata Cifkova; Serap E Erdine; Sverre Kjeldsen; Gregory Y H Lip; Krzysztof Narkiewicz; Gianfranco Parati; Josep Redon; Roland Schmieder; Costas Tsioufis; Giuseppe Mancia
Journal:  J Hypertens       Date:  2012-02       Impact factor: 4.844

6.  Blood pressure measurement in atrial fibrillation: review and meta-analysis of evidence on accuracy and clinical relevance.

Authors:  George S Stergiou; Konstantinos G Kyriakoulis; Emelina Stambolliu; Antonios Destounis; Nikos Karpettas; Petros Kalogeropoulos; Anastasios Kollias
Journal:  J Hypertens       Date:  2019-12       Impact factor: 4.844

7.  Automatic real time detection of atrial fibrillation.

Authors:  S Dash; K H Chon; S Lu; E A Raeder
Journal:  Ann Biomed Eng       Date:  2009-06-17       Impact factor: 3.934

8.  Diagnostic accuracy of a novel cuffless self-blood pressure monitor for atrial fibrillation screening in the elderly.

Authors:  Konstantinos G Kyriakoulis; Anastasios Kollias; Ioannis Anagnostopoulos; Areti Gravvani; Petros Kalogeropoulos; Antonios Destounis; George S Stergiou
Journal:  J Clin Hypertens (Greenwich)       Date:  2019-11-19       Impact factor: 3.738

Review 9.  2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: Executive summary.

Authors:  Hugh Calkins; Gerhard Hindricks; Riccardo Cappato; Young-Hoon Kim; Eduardo B Saad; Luis Aguinaga; Joseph G Akar; Vinay Badhwar; Josep Brugada; John Camm; Peng-Sheng Chen; Shih-Ann Chen; Mina K Chung; Jens Cosedis Nielsen; Anne B Curtis; D Wyn Davies; John D Day; André d'Avila; N M S Natasja de Groot; Luigi Di Biase; Mattias Duytschaever; James R Edgerton; Kenneth A Ellenbogen; Patrick T Ellinor; Sabine Ernst; Guilherme Fenelon; Edward P Gerstenfeld; David E Haines; Michel Haissaguerre; Robert H Helm; Elaine Hylek; Warren M Jackman; Jose Jalife; Jonathan M Kalman; Josef Kautzner; Hans Kottkamp; Karl Heinz Kuck; Koichiro Kumagai; Richard Lee; Thorsten Lewalter; Bruce D Lindsay; Laurent Macle; Moussa Mansour; Francis E Marchlinski; Gregory F Michaud; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Ken Okumura; Douglas Packer; Evgeny Pokushalov; Matthew R Reynolds; Prashanthan Sanders; Mauricio Scanavacca; Richard Schilling; Claudio Tondo; Hsuan-Ming Tsao; Atul Verma; David J Wilber; Teiichi Yamane
Journal:  Europace       Date:  2018-01-01       Impact factor: 5.214

10.  Accuracy of mHealth Devices for Atrial Fibrillation Screening: Systematic Review.

Authors:  Godwin Denk Giebel; Christian Gissel
Journal:  JMIR Mhealth Uhealth       Date:  2019-06-16       Impact factor: 4.773

  10 in total
  3 in total

1.  Diagnostic accuracy of a novel cuffless self-blood pressure monitor for atrial fibrillation screening in the elderly.

Authors:  Konstantinos G Kyriakoulis; Anastasios Kollias; Ioannis Anagnostopoulos; Areti Gravvani; Petros Kalogeropoulos; Antonios Destounis; George S Stergiou
Journal:  J Clin Hypertens (Greenwich)       Date:  2019-11-19       Impact factor: 3.738

2.  Perspectives on an ambulatory blood pressure monitoring device with novel technology for pulse waveform analysis to detect arrhythmias.

Authors:  Tomonori Watanabe; Naoko Tomitani; Kazuomi Kario
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-08-30       Impact factor: 3.738

3.  High prevalence of masked uncontrolled morning hypertension in elderly non-valvular atrial fibrillation patients: Home blood pressure substudy of the ANAFIE Registry.

Authors:  Kazuomi Kario; Naoyuki Hasebe; Ken Okumura; Takeshi Yamashita; Masaharu Akao; Hirotsugu Atarashi; Takanori Ikeda; Yukihiro Koretsune; Wataru Shimizu; Hiroyuki Tsutsui; Kazunori Toyoda; Atsushi Hirayama; Masahiro Yasaka; Takenori Yamaguchi; Satoshi Teramukai; Tetsuya Kimura; Jumpei Kaburagi; Atsushi Takita; Hiroshi Inoue
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-11-15       Impact factor: 3.738

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.