Literature DB >> 31737477

Osseodensification -- A systematic review and qualitative analysis of published literature.

Ninad Milind Padhye1, Ashvini Mukul Padhye2, Neel B Bhatavadekar3.   

Abstract

The recently introduced technique of osseodensification for dental implant involves the use of special drills (Densah) run in a counter-clockwise direction at the osteotomy site. It is claimed that this causes expansion of the osteotomy site, and increases density of the bone in immediate vicinity of the osteotomy. We reviewed published papers on the primary stability attained using this drilling technique. As a secondary finding, the bone to implant contact (BIC) and the bone area fraction occupancy (BAF) was also compared between the conventional drilling protocol and the osseodensification protocol, among these articles. A Systematic search was performed in PubMed-Medline, Embase and Google Scholar for clinical/animal studies up to November 2018. A total of 12 articles, from a database of 132 articles, consisting of 8 animal histologic studies, 2 human based clinical studies, 1 case series and 1 case report were assessed. 10/12 articles measured the insertion torque values, 7/12 articles measured the BIC and 6/12 articles estimated the BAF between the two techniques. Quality assessment of 8 studies performed using ARRIVE guidelines showed that 6/8 studies had a high score. An average increase in the insertion torque, BIC and BAF was noted in the osseodensification group as compared to the conventional drilling group. Since most of these studies are non-clinical, it can be inferred that osseodensification is an efficient way to enhance primary stability of implants in low density bone in an animal model. However, extrapolation to long term clinical success cannot be ascertained until further evidence becomes available.
© 2019 Craniofacial Research Foundation. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Dental implant; Implant primary stability; Implant stability; Osseodensification

Year:  2019        PMID: 31737477      PMCID: PMC6849357          DOI: 10.1016/j.jobcr.2019.10.002

Source DB:  PubMed          Journal:  J Oral Biol Craniofac Res        ISSN: 2212-4268


  52 in total

1.  The excessive loss of Branemark fixtures in type IV bone: a 5-year analysis.

Authors:  R A Jaffin; C L Berman
Journal:  J Periodontol       Date:  1991-01       Impact factor: 6.993

2.  Primary stability, insertion torque, and bone density of conical implants with internal hexagon: is there a relationship?

Authors:  Paolo Trisi; Davide Berardi; Michele Paolantonio; Giuseppe Spoto; Antonio D'Addona; Giorgio Perfetti
Journal:  J Craniofac Surg       Date:  2013-05       Impact factor: 1.046

3.  Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement.

Authors:  David Moher; Alessandro Liberati; Jennifer Tetzlaff; Douglas G Altman
Journal:  Ann Intern Med       Date:  2009-07-20       Impact factor: 25.391

4.  Implant micromotion is related to peak insertion torque and bone density.

Authors:  Paolo Trisi; Giorgio Perfetti; Edoardo Baldoni; Davide Berardi; Marco Colagiovanni; Giuseppe Scogna
Journal:  Clin Oral Implants Res       Date:  2009-05       Impact factor: 5.977

5.  Influence of mono- and bicortical anchorage on the integration of titanium implants. A study in the rabbit tibia.

Authors:  C J Ivanoff; L Sennerby; U Lekholm
Journal:  Int J Oral Maxillofac Surg       Date:  1996-06       Impact factor: 2.789

6.  Osseointegrated dental implants.

Authors:  T Albrektsson; T Jansson; U Lekholm
Journal:  Dent Clin North Am       Date:  1986-01

Review 7.  Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions.

Authors:  Dieter D Bosshardt; Vivianne Chappuis; Daniel Buser
Journal:  Periodontol 2000       Date:  2017-02       Impact factor: 7.589

8.  Significance of primary stability for osseointegration of dental implants.

Authors:  Natalia Lioubavina-Hack; Niklaus P Lang; Thorkild Karring
Journal:  Clin Oral Implants Res       Date:  2006-06       Impact factor: 5.977

Review 9.  Immediate nonfunctional versus immediate functional loading and dental implant failure rates: a systematic review and meta-analysis.

Authors:  Bruno Ramos Chrcanovic; Tomas Albrektsson; Ann Wennerberg
Journal:  J Dent       Date:  2014-07-01       Impact factor: 4.379

Review 10.  Dental endosseous implants in the medically compromised patient.

Authors:  C Scully; J Hobkirk; P D Dios
Journal:  J Oral Rehabil       Date:  2007-08       Impact factor: 3.837

View more
  5 in total

1.  Evaluation of crestal sinus floor elevations using versah burs with simultaneous implant placement, at residual bone height ≥ 2.0 _ < 6.0 mm. A prospective clinical study.

Authors:  Jenna Z Alhayati; Auday M Al-Anee
Journal:  Oral Maxillofac Surg       Date:  2022-05-14

2.  Evaluation of the primary stability in dental implants placed in low density bone with a new drilling technique, Osseodensification: an in vitro study.

Authors:  J Barberá-Millán; C Larrazábal-Morón; J-J Enciso-Ripoll; E Pérez-Pevida; D Chávarri-Prado; M-D Gómez-Adrián
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2021-05-01

3.  Implant Placement Post Maxillary Sinus Lift Using Osseodensification Concept: A Case Report.

Authors:  Anilkumar Rodda; Rekha R Koduganti; Harish K Manne; Pranavi Gullapelli; Laxmi Jaahnavi Devarampati
Journal:  Cureus       Date:  2022-01-31

4.  Lateral Window Design for Maxillary Sinus Graft Based on the Implant Position.

Authors:  Kyeong-Jun Cheon; Byoung-Eun Yang; Seoung-Won Cho; Sung-Min Chung; Soo-Hwan Byun
Journal:  Int J Environ Res Public Health       Date:  2020-08-31       Impact factor: 3.390

5.  Osseodensification effect on implants primary and secondary stability: Multicenter controlled clinical trial.

Authors:  Edmara T P Bergamo; Abbas Zahoui; Raúl Bravo Barrera; Salah Huwais; Paulo G Coelho; Edward Dwayne Karateew; Estevam A Bonfante
Journal:  Clin Implant Dent Relat Res       Date:  2021-05-27       Impact factor: 3.932

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.