Su-Ho Lim1, Won Mo Gu2, Soon Cheol Cha3.
Abstract
PURPOSE: To compare retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) thickness in patients with unilateral exfoliation syndrome (XFS) and age-matched controls using spectral domain-optical coherence tomography (SD-OCT).Entities:
Mesh:
Year: 2019 PMID: 31719674 PMCID: PMC7468570 DOI: 10.1038/s41433-019-0642-5
Source DB: PubMed Journal: Eye (Lond) ISSN: 0950-222X Impact factor: 3.775
Baseline characteristics of subjects
| XFS-affected eyes ( | Fellow eyes ( | Controls ( | ||
|---|---|---|---|---|
| Mean age | 73.3 ± 6.3 | 74.3 ± 7.2 | 0.536 | |
| Sex (M/F) | 18/9 | 20/7 | 0.551 | |
IOP (mmHg) [Range] | 17.2 ± 2.8 [13–20] | 16.8 ± 2.2 [12–20] | 14.5 ± 2.3 [12–19] | 0.004a |
| Lens status | ||||
| Phakic | 19 | 16 | 18 | 0.772 |
| Pseudophakic | 8 | 11 | 9 | |
| C/D ratio | 0.54 ± 0.16 | 0.53 ± 0.22 | 0.49 ± 0.19 | 0.759 |
Data are presented as mean ± SD; P values for mean age, sex, and lens status were calculated by independent t-tests and chi-square tests; other P values were calculated by one-way ANOVA
ANOVA analysis of variance, C/D cup/disc ratio, IOP intraocular pressure, XFS exfoliation syndrome
aPost-hoc analysis was performed using Tukey’s test; the P values for comparison of XFS affected eyes and fellow eyes was 0.763; the P value for comparison of XFS affected eyes and control eyes was 0.002; and the P value for comparison of fellow eyes and control eyes was 0.016
Comparison of retinal nerve fiber layer thickness among groups
| RNFL thickness (μm) | XFS-affected eyes ( | Fellow eyes ( | Controls ( | |
|---|---|---|---|---|
| Average | 93.4 ± 10.4 (85–116) | 94.2 ± 9.3 (88–117) | 96.3 ± 8.1 (89–124) | 0.057a |
| Nasal | 64.3 ± 12.1 (55–93) | 67.3 ± 10.1 (57–96) | 65.3 ± 9.3 (52–92) | 0.257 |
| Superior | 108.5 ± 13.5 (91–141) | 110.2 ± 15.2 (90–145) | 114.3 ± 12.2 (95–153) | 0.002b |
| Temporal | 72.3 ± 9.5 (59–101) | 74.3 ± 10.2 (61–104) | 74.2 ± 9.2 (65–105) | 0.681 |
| Inferior | 121.2 ± 14.2 (103–148) | 123.3 ± 15.2 (107–152) | 125.3 ± 10.4 (108–157) | 0.489 |
Data are presented as mean ± SD (range); P value was calculated by one-way ANOVA
ANOVA analysis of variance, RNFL retinal nerve fiber layer, XFS exfoliation syndrome
aAlthough the p value by ANOVA demonstrated statistical borderline significance, post-hoc analysis was performed using Tukey’s test. The P value for comparison of XFS-affected eyes and fellow eyes (P1) was 0.739; the P value for comparison of XFS-affected eyes and control (P2) eyes was 0.014; and the P value for comparison of fellow eyes and control eyes (P3) was 0.151
bPost-hoc analysis was performed using Tukey’s method: P1 = 0.607; P2 = 0.001, and P3 = 0.033
Comparison of ganglion cell complex thickness among groups
| GCC thickness (μm) | XFS-affected eyes ( | Fellow eyes ( | Control ( | |
|---|---|---|---|---|
| Average | 86.2 ± 6.4 | 87.5 ± 6.9 | 93.5 ± 6.0 | 0.032a |
| Superior | 86.1 ± 6.5 | 87.8 ± 6.3 | 94.6 ± 5.7 | 0.002b |
| Inferior | 86.3 ± 6.3 | 87.2 ± 7.4 | 92.3 ± 6.4 | 0.125 |
Data are presented as mean ± SD; P value was calculated by one-way ANOVA
ANOVA analysis of variance, GCC ganglion cell complex, XFS exfoliation syndrome
aPost-hoc analysis was performed using Tukey’s methods. The P value for comparison of XFS-affected eyes and fellow eyes (P1) was 0.629; the P value for comparison of XFS-affected eyes and control eyes (P2) was 0.026; and the P value for comparison of fellow eyes and control eyes (P3) was 0.049
bPost-hoc analysis was performed with Tukey’s method: P1 = 0.993; P2 = 0.001, and P3 = 0.004