Literature DB >> 31705805

Sparse deconvolution of proton radiography data to estimate water equivalent thickness maps.

Sylvain Deffet1, Paolo Farace2, Benoît Macq1.   

Abstract

PURPOSE: In proton therapy, the conversion of the planning computed tomography (CT) into proton stopping powers is tainted by uncertainties which may jeopardize dose conformity. Proton radiography provides a direct information on the energy reduction of protons in the patient. However, it is currently limited by the degradation ("blurring") of the one-dimensional depth-dose deposition profiles which constitute the pixels.
METHODS: An iterative algorithm is implemented to extract high-resolution water equivalent thickness (WET) maps from the measurements of depth-dose profiles acquired with a multilayer ionization chamber. The method relies on the assumption that those curves are a function of the WET, which can benefit from a sparse representation.
RESULTS: When used without relying on any prior knowledge derived from the planning CT, the method already outperforms the published one in terms of accuracy. We also propose a variant which integrates the planning CT in a robust fashion to further improve the deconvolution result and reach an accuracy of 1.5 mm on the estimated WET. The methods are applied to both synthetic data and actual proton radiography acquisitions on phantoms.
CONCLUSIONS: Besides the increase in accuracy achieved in the estimation of WET maps from proton radiography data, we demonstrate that the proposed deconvolution algorithm is also more robust with respect to confounding factors such as residual setup errors or changes in the anatomy. Therefore, proton radiography using a range probe provides both the required accuracy to assess and reduce range uncertainty in proton therapy and the simplicity of integrated-mode proton radiography.
© 2019 American Association of Physicists in Medicine.

Entities:  

Keywords:  deconvolution; multilayer ionization chamber; particle imaging; proton radiography; range uncertainty

Year:  2019        PMID: 31705805     DOI: 10.1002/mp.13917

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  A novel proton-integrating radiography system design using a monolithic scintillator detector: experimental studies.

Authors:  Chinmay D Darne; Daniel G Robertson; Fahed Alsanea; Charles-Antoine Collins-Fekete; Sam Beddar
Journal:  Nucl Instrum Methods Phys Res A       Date:  2021-12-16       Impact factor: 1.455

Review 2.  Adaptive proton therapy.

Authors:  Harald Paganetti; Pablo Botas; Gregory C Sharp; Brian Winey
Journal:  Phys Med Biol       Date:  2021-11-15       Impact factor: 3.609

3.  Estimation of leaf water content from hyperspectral data of different plant species by using three new spectral absorption indices.

Authors:  Hong Li; Wunian Yang; Junjie Lei; Jinxing She; Xiangshan Zhou
Journal:  PLoS One       Date:  2021-03-30       Impact factor: 3.240

Review 4.  Considerations for Upright Particle Therapy Patient Positioning and Associated Image Guidance.

Authors:  Lennart Volz; Yinxiangzi Sheng; Marco Durante; Christian Graeff
Journal:  Front Oncol       Date:  2022-07-29       Impact factor: 5.738

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.