Literature DB >> 31703217

Radiation dose efficiency of multi-energy photon-counting-detector CT for dual-contrast imaging.

Liqiang Ren1, Kishore Rajendran, Cynthia H McCollough, Lifeng Yu.   

Abstract

Compared to traditional multi-scan single-energy CT (SECT), one potential advantage of single-scan multi-energy CT (MECT) proposed for simultaneous imaging of multiple contrast agents is the radiation dose reduction. This phantom study aims to rigorously evaluate whether the radiation dose can truly be reduced in a single-scan MECT protocol (MECT_1s) in biphasic liver imaging with iodine and gadolinium, and small bowel imaging with iodine and bismuth, compared to traditional two-scan SECT protocols (SECT_2s). For MECT_1s, mixed iodine/gadolinium samples were prepared corresponding to late arterial/portal-venous phase for biphasic liver imaging. Mixed iodine/bismuth samples were prepared representing the arterial/enteric enhancement for small bowel imaging. For SECT_2s, separate contrast samples were prepared to mimic separate scans in arterial/venous phase and arterial/enteric enhancement. Samples were placed in a 35 cm wide water phantom and scanned by a research whole-body photon-counting-detector-CT (PCD-CT) system ('chess' mode). MECT images were acquired with optimized kV/threshold settings for each imaging task, and SECT images were acquired at 120 kV. Total CTDIvol was matched for the two protocols. Image-based three-material decomposition was employed in MECT_1s to determine the basis material concentration values, which were converted to CT numbers at 120 kV (i.e. virtual SECT images) to compare with the SECT images directly acquired with SECT_2s. The noise difference between the SECT and the virtual SECT images was compared to evaluate the dose efficiency of MECT_1s. Compared to SECT_2s, MECT_1s was not dose efficient for both imaging tasks. The amount of noise increase is highly task dependent, with noise increased by 203%/278% and 110%/82% in virtual SECT images for iodine/gadolinium and iodine/bismuth quantifications, respectively, corresponding to dose increase by 819%/1328% and 340%/230% in MECT_1s to achieve the same image noise level. MECT with the current PCD-CT technique requires higher radiation dose than SECT to achieve the same image quality.

Entities:  

Year:  2019        PMID: 31703217      PMCID: PMC6980362          DOI: 10.1088/1361-6560/ab55bf

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  31 in total

1.  Adaptive nonlocal means filtering based on local noise level for CT denoising.

Authors:  Zhoubo Li; Lifeng Yu; Joshua D Trzasko; David S Lake; Daniel J Blezek; Joel G Fletcher; Cynthia H McCollough; Armando Manduca
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

2.  Material decomposition with prior knowledge aware iterative denoising (MD-PKAID).

Authors:  Shengzhen Tao; Kishore Rajendran; Cynthia H McCollough; Shuai Leng
Journal:  Phys Med Biol       Date:  2018-09-21       Impact factor: 3.609

3.  Quantitative accuracy and dose efficiency of dual-contrast imaging using dual-energy CT: a phantom study.

Authors:  Liqiang Ren; Kishore Rajendran; Cynthia H McCollough; Lifeng Yu
Journal:  Med Phys       Date:  2019-12-10       Impact factor: 4.071

4.  Comparison of a Photon-Counting-Detector CT with an Energy-Integrating-Detector CT for Temporal Bone Imaging: A Cadaveric Study.

Authors:  W Zhou; J I Lane; M L Carlson; M R Bruesewitz; R J Witte; K K Koeller; L J Eckel; R E Carter; C H McCollough; S Leng
Journal:  AJNR Am J Neuroradiol       Date:  2018-08-09       Impact factor: 3.825

5.  Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon-counting detector computed tomography system.

Authors:  Wei Zhou; Juan Montoya; Ralf Gutjahr; Andrea Ferrero; Ahmed Halaweish; Steffen Kappler; Cynthia McCollough; Shuai Leng
Journal:  J Med Imaging (Bellingham)       Date:  2017-11-16

6.  Toward biphasic computed tomography (CT) enteric contrast: material classification of luminal bismuth and mural iodine in a small-bowel phantom using dual-energy CT.

Authors:  Mingliang Qu; Eric Ehman; Joel G Fletcher; James E Huprich; Amy K Hara; Alvin C Silva; Gianrico Farrugia; Paul Limburg; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2012 Sep-Oct       Impact factor: 1.826

Review 7.  Gadolinium deposition and the potential for toxicological sequelae - A literature review of issues surrounding gadolinium-based contrast agents.

Authors:  Kerry A Layne; Paul I Dargan; John R H Archer; David M Wood
Journal:  Br J Clin Pharmacol       Date:  2018-08-17       Impact factor: 4.335

Review 8.  Tutorial on X-ray photon counting detector characterization.

Authors:  Liqiang Ren; Bin Zheng; Hong Liu
Journal:  J Xray Sci Technol       Date:  2018       Impact factor: 1.535

9.  Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies.

Authors:  Ralf Gutjahr; Ahmed F Halaweish; Zhicong Yu; Shuai Leng; Lifeng Yu; Zhoubo Li; Steven M Jorgensen; Erik L Ritman; Steffen Kappler; Cynthia H McCollough
Journal:  Invest Radiol       Date:  2016-07       Impact factor: 6.016

10.  Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array.

Authors:  Zhicong Yu; Shuai Leng; Steven M Jorgensen; Zhoubo Li; Ralf Gutjahr; Baiyu Chen; Ahmed F Halaweish; Steffen Kappler; Lifeng Yu; Erik L Ritman; Cynthia H McCollough
Journal:  Phys Med Biol       Date:  2016-02-02       Impact factor: 3.609

View more
  12 in total

1.  Quantitative accuracy and dose efficiency of dual-contrast imaging using dual-energy CT: a phantom study.

Authors:  Liqiang Ren; Kishore Rajendran; Cynthia H McCollough; Lifeng Yu
Journal:  Med Phys       Date:  2019-12-10       Impact factor: 4.071

2.  Simultaneous dual-contrast imaging using energy-integrating detector multi-energy CT: An in vivo feasibility study.

Authors:  Zhongxing Zhou; Liqiang Ren; Kishore Rajendran; Felix E Diehn; Joel G Fletcher; Cynthia H McCollough; Lifeng Yu
Journal:  Med Phys       Date:  2022-01-27       Impact factor: 4.071

3.  Improved coronary calcium detection and quantification with low-dose full field-of-view photon-counting CT: a phantom study.

Authors:  N R van der Werf; P A Rodesch; S Si-Mohamed; R W van Hamersvelt; M J W Greuter; T Leiner; L Boussel; M J Willemink; P Douek
Journal:  Eur Radiol       Date:  2022-01-08       Impact factor: 5.315

4.  Dual-Contrast Biphasic Liver Imaging With Iodine and Gadolinium Using Photon-Counting Detector Computed Tomography: An Exploratory Animal Study.

Authors:  Liqiang Ren; Nathan Huber; Kishore Rajendran; Joel G Fletcher; Cynthia H McCollough; Lifeng Yu
Journal:  Invest Radiol       Date:  2022-02-01       Impact factor: 6.016

5.  Photon Counting CT: Clinical Applications and Future Developments.

Authors:  Scott S Hsieh; Shuai Leng; Kishore Rajendran; Shengzhen Tao; Cynthia H McCollough
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-08-28

6.  Spectral Photon Counting CT: Imaging Algorithms and Performance Assessment.

Authors:  Adam S Wang; Norbert J Pelc
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-07-07

7.  Comparison of Low Dose Performance of Photon-Counting and Energy Integrating CT.

Authors:  Jayasai R Rajagopal; Faraz Farhadi; Justin Solomon; Pooyan Sahbaee; Babak Saboury; William F Pritchard; Elizabeth C Jones; Ehsan Samei
Journal:  Acad Radiol       Date:  2020-08-24       Impact factor: 3.173

8.  Improved coronary calcification quantification using photon-counting-detector CT: an ex vivo study in cadaveric specimens.

Authors:  Mårten Sandstedt; Jeffrey Marsh; Kishore Rajendran; Hao Gong; Shengzhen Tao; Anders Persson; Shuai Leng; Cynthia McCollough
Journal:  Eur Radiol       Date:  2021-03-13       Impact factor: 5.315

9.  Artificial Intelligence Algorithm-Based Differential Diagnosis of Crohn's Disease and Ulcerative Colitis by CT Image.

Authors:  Fangyun Jiang; Xiaoping Fu; Kai Kuang; Dan Fan
Journal:  Comput Math Methods Med       Date:  2022-04-04       Impact factor: 2.238

10.  Simultaneous Dual-Contrast Imaging of Small Bowel With Iodine and Bismuth Using Photon-Counting-Detector Computed Tomography: A Feasibility Animal Study.

Authors:  Liqiang Ren; Kishore Rajendran; Joel G Fletcher; Cynthia H McCollough; Lifeng Yu
Journal:  Invest Radiol       Date:  2020-10       Impact factor: 10.065

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.