Literature DB >> 3168731

Check-size specific changes of pattern electroretinogram in patients with early open-angle glaucoma.

M Bach1, P Hiss, J Röver.   

Abstract

The pattern electroretinogram was recorded in patients with initial stages of visual field defects due to open-angle glaucoma and in age-matched normal subjects. Both normal subjects and glaucoma patients had a visual acuity above 0.8. Counterphasing checkerboard patterns were used as visual stimuli with a range of check sizes from 0.8 degree to 15 degrees at 7.8 reversals/s. Whereas the amplitude in glaucoma patients was nearly normal for large check sizes, it was significantly reduced for small check sizes (p = 0.003). Possibly two separate mechanisms that generate the pattern electroretinogram for small and large checks are differentially affected; they may be related to the magnocellular and parvocellular systems. The difference between normals and glaucoma patients was even more significant when the ratios of the amplitudes at small and large check sizes were compared (p less than 0.0002). When this ratios is used, the amplitude variability can be partly overcome and the pattern electroretinogram can be a sensitive indicator of ganglion cell function.

Entities:  

Mesh:

Year:  1988        PMID: 3168731     DOI: 10.1007/bf00154412

Source DB:  PubMed          Journal:  Doc Ophthalmol        ISSN: 0012-4486            Impact factor:   2.379


  13 in total

1.  A gold foil electrode: extending the horizons for clinical electroretinography.

Authors:  G B Arden; R M Carter; C Hogg; I M Siegel; S Margolis
Journal:  Invest Ophthalmol Vis Sci       Date:  1979-04       Impact factor: 4.799

2.  Pattern electroretinogram plus visual evoked potential: a decisive test in patients suspected of malingering.

Authors:  J Röver; M Bach
Journal:  Doc Ophthalmol       Date:  1987-06       Impact factor: 2.379

3.  Complementary components and local variations of the pattern electroretinogram.

Authors:  N Drasdo; D A Thompson; C M Thompson; L Edwards
Journal:  Invest Ophthalmol Vis Sci       Date:  1987-01       Impact factor: 4.799

4.  [Light and pattern ERG in advanced glaucoma].

Authors:  N Papst; M Bopp; O E Schnaudigel
Journal:  Klin Monbl Augenheilkd       Date:  1984-03       Impact factor: 0.700

5.  The pattern evoked electroretinogram: its variability in normals and its relationship to amblyopia.

Authors:  R F Hess; C L Baker; J N Verhoeve; U T Keesey; T D France
Journal:  Invest Ophthalmol Vis Sci       Date:  1985-11       Impact factor: 4.799

6.  Retinal ganglion cells that project to the dorsal lateral geniculate nucleus in the macaque monkey.

Authors:  V H Perry; R Oehler; A Cowey
Journal:  Neuroscience       Date:  1984-08       Impact factor: 3.590

7.  Spatial and temporal frequency tuning of pattern-reversal retinal potentials.

Authors:  G L Trick; D H Wintermeyer
Journal:  Invest Ophthalmol Vis Sci       Date:  1982-12       Impact factor: 4.799

8.  Retinal potentials in patients with primary open-angle glaucoma: physiological evidence for temporal frequency tuning deficits.

Authors:  G L Trick
Journal:  Invest Ophthalmol Vis Sci       Date:  1985-12       Impact factor: 4.799

9.  Pattern-reversal electroretinograms in ocular hypertension.

Authors:  P Wanger; H E Persson
Journal:  Doc Ophthalmol       Date:  1985-10-30       Impact factor: 2.379

10.  The pattern-elicited electroretinogram. I. A tool in the early detection of glaucoma?

Authors:  P J Ringens; S Vijfvinkel-Bruinenga; G H van Lith
Journal:  Ophthalmologica       Date:  1986       Impact factor: 3.250

View more
  28 in total

1.  The multifocal ERG in open angle glaucoma--a comparison of high and low contrast recordings in high- and low-tension open angle glaucoma.

Authors:  A M Palmowski; R Allgayer; B Heinemann-Vemaleken
Journal:  Doc Ophthalmol       Date:  2000-07       Impact factor: 2.379

2.  Normative data for a user-friendly paradigm for pattern electroretinogram recording.

Authors:  Vittorio Porciatti; Lori M Ventura
Journal:  Ophthalmology       Date:  2004-01       Impact factor: 12.079

3.  Different effect of dioptric defocus vs. light scatter on the pattern electroretinogram (PERG).

Authors:  Michael Bach; Marcel Mathieu
Journal:  Doc Ophthalmol       Date:  2004-01       Impact factor: 2.379

4.  [Electrophysiological examination methods in glaucoma diagnostics].

Authors:  C M Poloschek; M Bach
Journal:  Ophthalmologe       Date:  2012-04       Impact factor: 1.059

5.  Retinal pathway origins of the pattern electroretinogram (PERG).

Authors:  Xunda Luo; Laura J Frishman
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-11-01       Impact factor: 4.799

6.  Pattern electroretinogram in glaucoma and ocular hypertension.

Authors:  M Bach; A Speidel-Fiaux
Journal:  Doc Ophthalmol       Date:  1989-10       Impact factor: 2.379

7.  The pattern electroretinogram in glaucoma and ocular hypertension.

Authors:  E O'Donaghue; G B Arden; F O'Sullivan; F Falcão-Reis; B Moriarty; R A Hitchings; W Spilleers; C Hogg; G Weinstein
Journal:  Br J Ophthalmol       Date:  1992-07       Impact factor: 4.638

8.  Multifocal electroretinographical changes in monkeys with experimental ocular hypertension: a longitudinal study.

Authors:  Jan Kremers; Arno Doelemeyer; Elzbieta A Polska; Fabrice Moret; Christian Lambert; George N Lambrou
Journal:  Doc Ophthalmol       Date:  2008-01-01       Impact factor: 2.379

9.  PERG and spectral sensitivity in ocular hypertensive and chronic open-angle glaucoma patients.

Authors:  M Bielik; F Zwas; D H Shin; C S Tsai
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1991       Impact factor: 3.117

10.  Adaptation of the steady-state PERG in early glaucoma.

Authors:  Vittorio Porciatti; Brandon Bosse; Prashant K Parekh; Olga A Shif; William J Feuer; Lori M Ventura
Journal:  J Glaucoma       Date:  2014 Oct-Nov       Impact factor: 2.503

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.