Literature DB >> 12914881

Usefulness of a cobalt chromium coronary stent alloy.

Dean J Kereiakes1, David A Cox, James B Hermiller, Mark G Midei, William B Bachinsky, E Dean Nukta, Martin B Leon, Stanley Fink, Linda Marin, Alexandra J Lansky.   

Abstract

The cobalt chromium Guidant Multi-Link Vision coronary stent was deployed in 267 patients as part of a multicenter international registry. Major adverse cardiovascular events were infrequent, and late (180 days) quantitative angiography demonstrated binary (>50%) in-stent restenosis in 15.7% of patients. This registry establishes the safety and efficacy of this alloy as a coronary stent platform.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12914881     DOI: 10.1016/s0002-9149(03)00669-6

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  33 in total

1.  One-year clinical follow-up of a registry evaluating a percutaneous revascularisation strategy combining a pre-specified simple selection process with the use of a new thin-strut bare cobalt-chromium stent.

Authors:  P R Stella; G Pavlakis; P Agostoni; H M Nathoe; S Hoseyni Guyomi; B J Hamer; T X Wildbergh; P A Doevendans; E Van Belle
Journal:  Neth Heart J       Date:  2010-10       Impact factor: 2.380

Review 2.  Emerging applications of nanotechnology for the diagnosis and management of vulnerable atherosclerotic plaques.

Authors:  Shann S Yu; Ryan A Ortega; Brendan W Reagan; John A McPherson; Hak-Joon Sung; Todd D Giorgio
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2011-08-10

Review 3.  Coronary stents: in these days of climate change should all stents wear coats?

Authors:  R Lowe; I B A Menown; G Nogareda; I M Penn
Journal:  Heart       Date:  2005-06       Impact factor: 5.994

Review 4.  Coronary artery stents: identification and evaluation.

Authors:  J Butany; K Carmichael; S W Leong; M J Collins
Journal:  J Clin Pathol       Date:  2005-08       Impact factor: 3.411

5.  Experience with biodegradable polymer coated sirolimus-eluting coronary stent system in "real-life" percutaneous coronary intervention: 24-month data from the manipal-s registry.

Authors:  Ranjan Shetty; G Vivek; Ashok Thakkar; Supriya Sunder Mishra; Vivek Joseph; Mithun Gopal Devraj; Anil Tumkur; Umesh Pai
Journal:  J Clin Diagn Res       Date:  2013-09-10

6.  In vivo Evaluation of Cenderitide-Eluting Stent (CES) II.

Authors:  Yingying Huang; Xu Wen Ng; Soon Ghim Lim; Horng Haur Chen; John C Burnett; Yin Chiang Freddy Boey; Subbu S Venkatraman
Journal:  Ann Biomed Eng       Date:  2015-07-16       Impact factor: 3.934

Review 7.  Enhancing Stent Effectiveness with Nanofeatures.

Authors:  Nicole Bassous; John P Cooke; Thomas J Webster
Journal:  Methodist Debakey Cardiovasc J       Date:  2016-09

8.  Systematical evolution on a Zn-Mg alloy potentially developed for biodegradable cardiovascular stents.

Authors:  Song Lin; Xiaolin Ran; Xinhao Yan; Qilong Wang; Jack G Zhou; Tingzhang Hu; Guixue Wang
Journal:  J Mater Sci Mater Med       Date:  2019-11-01       Impact factor: 3.896

9.  A first-in-man study of sirolimus-eluting, biodegradable polymer coated cobalt chromium stent in real life patients.

Authors:  Ashok Seth; Praveen Chandra; Nagendra S Chouhan; Ashok S Thakkar
Journal:  Indian Heart J       Date:  2012-07-27

10.  In vitro endothelialization of cobalt chromium alloys with micro/nanostructures using adipose-derived stem cells.

Authors:  Zhilong Shi; K G Neoh; E T Kang
Journal:  J Mater Sci Mater Med       Date:  2013-01-31       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.