Literature DB >> 19000636

In vitro corrosion and biocompatibility of binary magnesium alloys.

Xuenan Gu1, Yufeng Zheng, Yan Cheng, Shengping Zhong, Tingfei Xi.   

Abstract

As bioabsorbable materials, magnesium alloys are expected to be totally degraded in the body and their biocorrosion products not deleterious to the surrounding tissues. It's critical that the alloying elements are carefully selected in consideration of their cytotoxicity and hemocompatibility. In the present study, nine alloying elements Al, Ag, In, Mn, Si, Sn, Y, Zn and Zr were added into magnesium individually to fabricate binary Mg-1X (wt.%) alloys. Pure magnesium was used as control. Their mechanical properties, corrosion properties and in vitro biocompatibilities (cytotoxicity and hemocompatibility) were evaluated by SEM, XRD, tensile test, immersion test, electrochemical corrosion test, cell culture and platelet adhesion test. The results showed that the addition of alloying elements could influence the strength and corrosion resistance of Mg. The cytotoxicity tests indicated that Mg-1Al, Mg-1Sn and Mg-1Zn alloy extracts showed no significant reduced cell viability to fibroblasts (L-929 and NIH3T3) and osteoblasts (MC3T3-E1); Mg-1Al and Mg-1Zn alloy extracts indicated no negative effect on viabilities of blood vessel related cells, ECV304 and VSMC. It was found that hemolysis and the amount of adhered platelets decreased after alloying for all Mg-1X alloys as compared to the pure magnesium control. The relationship between the corrosion products and the in vitro biocompatibility had been discussed and the suitable alloying elements for the biomedical applications associated with bone and blood vessel had been proposed.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19000636     DOI: 10.1016/j.biomaterials.2008.10.021

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  102 in total

1.  Endothelial responses of magnesium and other alloying elements in magnesium-based stent materials.

Authors:  Nan Zhao; Donghui Zhu
Journal:  Metallomics       Date:  2014-11-03       Impact factor: 4.526

2.  In vitro degradation behavior and cytocompatibility of Mg-Zn-Zr alloys.

Authors:  Z G Huan; M A Leeflang; J Zhou; L E Fratila-Apachitei; J Duszczyk
Journal:  J Mater Sci Mater Med       Date:  2010-06-09       Impact factor: 3.896

3.  Biocorrosion properties and blood and cell compatibility of pure iron as a biodegradable biomaterial.

Authors:  Erlin Zhang; Haiyan Chen; Feng Shen
Journal:  J Mater Sci Mater Med       Date:  2010-04-16       Impact factor: 3.896

Review 4.  Current progress in inorganic artificial biomaterials.

Authors:  Zhixia Li; Masakazu Kawashita
Journal:  J Artif Organs       Date:  2011-07-07       Impact factor: 1.731

5.  Evaluation of a new Mg-Zn-Ca-Y alloy for biomedical application.

Authors:  Yang Qu; Mingyang Kang; Rongpeng Dong; Jiansheng Liu; Junyang Liu; Jianwu Zhao
Journal:  J Mater Sci Mater Med       Date:  2015-01-13       Impact factor: 3.896

6.  Investigation of the antimicrobial activity and biocompatibility of magnesium alloy coated with HA and antimicrobial peptide.

Authors:  Jinhuan Tian; Si Shen; Changren Zhou; Xiangli Dang; Yanpeng Jiao; Lihua Li; Shan Ding; Hong Li
Journal:  J Mater Sci Mater Med       Date:  2015-01-29       Impact factor: 3.896

7.  Assessment of in vitro temporal corrosion and cytotoxicity of AZ91D alloy.

Authors:  Costantino Del Gaudio; Paolo Bagalà; Marco Venturini; Claudio Grandi; Pier Paolo Parnigotto; Alessandra Bianco; Giampiero Montesperelli
Journal:  J Mater Sci Mater Med       Date:  2012-07-17       Impact factor: 3.896

8.  In vitro corrosion resistance and cytocompatibility of nano-hydroxyapatite reinforced Mg-Zn-Zr composites.

Authors:  Xinyu Ye; Minfang Chen; Meng Yang; Jun Wei; Debao Liu
Journal:  J Mater Sci Mater Med       Date:  2009-12-12       Impact factor: 3.896

9.  Cytocompatibility of magnesium and AZ31 alloy with three types of cell lines using a direct in vitro method.

Authors:  Akira Mochizuki; Chie Yahata; Hung Takai
Journal:  J Mater Sci Mater Med       Date:  2016-08-27       Impact factor: 3.896

Review 10.  A feasibility study of using biodegradable magnesium alloy in glaucoma drainage device.

Authors:  Xiang-Ji Li; Lin Xie; Fu-Sheng Pan; Yong Wang; Hong Liu; Yu-Rong Tang; Cindy Ml Hutnik
Journal:  Int J Ophthalmol       Date:  2018-01-18       Impact factor: 1.779

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.