Literature DB >> 31656742

Characteristics of current digital single-use flexible ureteroscopes versus their reusable counterparts: an in-vitro comparative analysis.

Laurian B Dragos1,2,3, Bhaskar K Somani3,4, Etienne X Keller5, Vincent M J De Coninck5, Maria Rodriguez-Monsalve Herrero5, Guido M Kamphuis3,6, Ewa Bres-Niewada7, Emre T Sener3,8, Steeve Doizi3,5,9, Oliver J Wiseman1, Olivier Traxer3,5,9.   

Abstract

BACKGROUND: Single-use flexible ureterorenoscopes (fURSs) have been recently introduced aiming to offer solutions to the sterilization, fragility and cost issues of the reusable fURSs. In order to be a viable alternative, the single-use scopes must prove similar capabilities when compared to their reusable counterparts. The goal of our in-vitro study was to compare the current reusable and single-use digital fURSs regarding their deflection, irrigation and vision characteristics.
METHODS: We compared in-vitro 4 single-use fURSs-LithoVue™ (Boston Scientific, Marlborough, Massachusetts, USA), Uscope™ (Zhuhai Pusen Medical Technology Co. Ltd., Zhuhai, Guangdong Province, China), NeoFlex™ (NeoScope Inc, San Jose, California, USA) and ShaoGang™ (YouCare Technology Co. Ltd., Wuhan, China) versus 4 reusable fURSs-FLEX-Xc (Karl Storz SE & Co KG, Tuttlingen, Germany), URF-V2 (Olympus, Shinjuku, Tokyo, Japan), COBRA vision and BOA vision (Richard Wolf GmbH, Knittlingen, Germany). Deflection and irrigation abilities were evaluated with different instruments inserted through the working channel: laser fibres (200/273/365 µm), retrieval baskets (1.5/1.9/2.2 Fr), guide wires [polytetrafluoroethylene (PTFE) 0.038 inch, nitinol 0.035 inch] and a biopsy forceps. A scoring system was designed to compare the deflection impairment. Saline at different heights (40/80 cm) was used for irrigation. The flow was measured with the tip of the fURS initially straight and then fully deflected. The vision characteristics were evaluated (field of view, depth of field, image resolution, distortion and colour representation) using specific target models.
RESULTS: Overall, the single-use fURSs had superior in-vitro deflection abilities than the reusable fURSs, in most settings. The highest score was achieved by NeoFlex™ and the lowest by ShaoGang™. PTFE guide wire had most impact on deflection for all fURSs. The 200 µm laser fibre had the lowest impact on deflection for the single-use fURSs. The 1.5 Fr basket caused the least deflection impairment on reusable fURSs. At the end of the tests, deflection loss was noted in most of the single-use fURSs, while none of the reusable fURSs presented deflection impairment. ShaoGang™ had the highest irrigation flow. Increasing the size of the instruments occupying the working channel led to decrease of irrigation flow in all fURSs. The impact of maximal deflection on irrigation flow was very low for all fURSs. When instruments were occupying the working channel, the single-use fURSs had slightly better in-vitro irrigation flow than the reusable fURSs. The field of view was comparable for all fURSs, with LithoVue™ showing a slight advantage. Depth of field and colour reproducibility were almost similar for all fURSs. ShaoGang™ and Uscope™ had the lowest resolution. FLEX Xc had the highest image distortion while LithoVue™ had the lowest. Partial field of view impairment was not for Uscope™ and ShaoGang™.
CONCLUSIONS: In-vitro, there are differences in technical characteristics of fURSs. It appears that single-use fURSs deflect better than their reusable counterparts. Irrespective of deflection, the irrigation flow of the single-use fURSs was slightly superior to the flow of the reusable fURSs. Overall, reusable fURSs had better vision characteristics than single-use fURSs. Further in-vivo studies might be necessary to confirm these findings. 2019 Translational Andrology and Urology. All rights reserved.

Entities:  

Keywords:  Single-use; digital flexible ureteroscopes; reusable

Year:  2019        PMID: 31656742      PMCID: PMC6790413          DOI: 10.21037/tau.2019.09.17

Source DB:  PubMed          Journal:  Transl Androl Urol        ISSN: 2223-4683


  29 in total

Review 1.  Appropriate kidney stone size for ureteroscopic lithotripsy: When to switch to a percutaneous approach.

Authors:  Ryoji Takazawa; Sachi Kitayama; Toshihiko Tsujii
Journal:  World J Nephrol       Date:  2015-02-06

2.  Trends in Upper Tract Stone Disease in England: Evidence from the Hospital Episodes Statistics Database.

Authors:  Nicholas J Rukin; Zain A Siddiqui; Edmund C P Chedgy; Bhaskar K Somani
Journal:  Urol Int       Date:  2016-10-01       Impact factor: 2.089

3.  A Prospective Case-Control Study Comparing LithoVue, a Single-Use, Flexible Disposable Ureteroscope, with Flexible, Reusable Fiber-Optic Ureteroscopes.

Authors:  Manint Usawachintachit; Dylan S Isaacson; Kazumi Taguchi; David T Tzou; Ryan S Hsi; Benjamin A Sherer; Marshall L Stoller; Thomas Chi
Journal:  J Endourol       Date:  2017-03-13       Impact factor: 2.942

4.  Which Flexible Ureteroscopes (Digital vs. Fiber-Optic) Can Easily Reach the Difficult Lower Pole Calices and Have Better End-Tip Deflection: In Vitro Study on K-Box. A PETRA Evaluation.

Authors:  Laurian B Dragos; Bhaskar K Somani; Emre T Sener; Salvatore Buttice; Silvia Proietti; Achilles Ploumidis; Catalin T Iacoboaie; Steeve Doizi; Olivier Traxer
Journal:  J Endourol       Date:  2017-06-13       Impact factor: 2.942

5.  In Vitro Comparison of Maximum Pressure Developed by Irrigation Systems in a Kidney Model.

Authors:  Silvia Proietti; Laurian Dragos; Bhaskar Somani; Salvatore Butticè; Michele Talso; Esteban Emiliani; Mohamed Baghdadi; Guido Giusti; Olivier Traxer
Journal:  J Endourol       Date:  2017-05       Impact factor: 2.942

6.  The clinical research office of the endourological society ureteroscopy global study: indications, complications, and outcomes in 11,885 patients.

Authors:  Jean de la Rosette; John Denstedt; Petrisor Geavlete; Francis Keeley; Tadashi Matsuda; Margaret Pearle; Glenn Preminger; Olivier Traxer
Journal:  J Endourol       Date:  2013-12-17       Impact factor: 2.942

Review 7.  EAU Guidelines on Interventional Treatment for Urolithiasis.

Authors:  Christian Türk; Aleš Petřík; Kemal Sarica; Christian Seitz; Andreas Skolarikos; Michael Straub; Thomas Knoll
Journal:  Eur Urol       Date:  2015-09-04       Impact factor: 20.096

8.  Intrarenal Surgery vs Percutaneous Nephrolithotomy in the Management of Lower Pole Stones Greater than 2 cm.

Authors:  Hakan Koyuncu; Faruk Yencilek; Mehmet Kalkan; Yavuz Bastug; Esin Yencilek; Ahmet Tunc Ozdemir
Journal:  Int Braz J Urol       Date:  2015 Mar-Apr       Impact factor: 1.541

9.  LithoVue™: A new single-use digital flexible ureteroscope.

Authors:  Salvatore Butticè; Tarik Emre Sener; Christopher Netsch; Esteban Emiliani; Rosa Pappalardo; Carlo Magno
Journal:  Cent European J Urol       Date:  2016-08-26

10.  First clinical evaluation of the new single-use flexible and semirigid Pusen ureteroscopes.

Authors:  Esteban Emiliani; Asier Mercadé; Félix Millan; Francisco Sánchez-Martín; Cristian Andrés Konstantinidis; Oriol Angerri
Journal:  Cent European J Urol       Date:  2018-04-09
View more
  4 in total

1.  Consultation on kidney stones, Copenhagen 2019: aspects of intracorporeal lithotripsy in flexible ureterorenoscopy.

Authors:  Søren Kissow Lildal; Kim Hovgaard Andreassen; Joyce Baard; Marianne Brehmer; Matthew Bultitude; Ylva Eriksson; Khurshid R Ghani; Helene Jung; Guido Kamphuis; Peter Kronenberg; Ben Turney; Olivier Traxer; Øyvind Ulvik; Palle Jörn Sloth Osther
Journal:  World J Urol       Date:  2020-10-16       Impact factor: 4.226

Review 2.  Repair Rate and Associated Costs of Reusable Flexible Ureteroscopes: A Systematic Review and Meta-analysis.

Authors:  Dinah K Rindorf; Thomas Tailly; Guido M Kamphuis; Sara Larsen; Bhaskar K Somani; Olivier Traxer; Kevin Koo
Journal:  Eur Urol Open Sci       Date:  2022-01-29

Review 3.  Single-use flexible ureteroscopes: update and perspective in developing countries. A narrative review.

Authors:  Eduardo Mazzucchi; Giovanni Scala Marchini; Fernanda Christina Gabrigna Berto; John Denstedt; Alexandre Danilovic; Fabio Carvalho Vicentini; Fabio Cesar Miranda Torricelli; Carlos Alfredo Battagello; Miguel Srougi; William Carlos Nahas
Journal:  Int Braz J Urol       Date:  2022 May-Jun       Impact factor: 3.050

Review 4.  Hybrid flexible ureteroscopy strategy in the management of renal stones - a narrative review.

Authors:  Bogdan Geavlete; Cristian Mareș; Răzvan Mulțescu; Dragoș Georgescu; Petrișor Geavlete
Journal:  J Med Life       Date:  2022-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.