Literature DB >> 28478744

Which Flexible Ureteroscopes (Digital vs. Fiber-Optic) Can Easily Reach the Difficult Lower Pole Calices and Have Better End-Tip Deflection: In Vitro Study on K-Box. A PETRA Evaluation.

Laurian B Dragos1,2, Bhaskar K Somani2,3, Emre T Sener2,4, Salvatore Buttice2,5, Silvia Proietti2,6, Achilles Ploumidis2,7, Catalin T Iacoboaie8, Steeve Doizi2,8,9, Olivier Traxer2,9.   

Abstract

BACKGROUND AND
PURPOSE: Modern flexible ureteroscopes (fURSs) have good deflection, but despite this, approaching an acute angled calix can still be difficult. The goals of our in vitro study were to assess the ability of the available modern fURSs to effectively access the sharp angled calices and to compare the end-tip deflection of the various fiber-optic and digital fURSs.
MATERIALS AND METHODS: Using a bench-training model for FURS (K-Box, Porgès-Coloplast), we tried to access an acute angled calix with nine different fURSs (BOA vision, COBRA vision, R.Wolf; FLEX X2, FLEX Xc, K.Storz; LithoVue, Boston Scientific; URF-P5, URF-P6, URF-V, URF-V2, Olympus). Passing the fURSs through a ureteral access sheath (ReTrace, Porgès-Coloplast), the maximum end-tip deflection for every fURS was measured with the tip extended out from the sheath at 1, 2, 3, and 4 cm. Two ranking methods were designed for scoring the fURSs, one based on total ranking points and the other on total degrees of deflection.
RESULTS: While all fiber-optic fURSs (except URF-P6) were able to access the sharp angled calix, none of the digital fURSs (except FLEX Xc) reached the difficult angled calix. Similarly, all fiber-optic fURSs had better end-tip deflection compared with the digital fURSs, except FLEX Xc, which was as deflectable as the fiber-optic fURSs. The fURSs showed an end-tip deflection (median difference of almost 21°) in favor of fiber-optic fURSs. Based on the scoring, the highest ranked fURS (best deflection) was FLEX X2 and the lowest ranked fURS (worst deflection) was URF-V2.
CONCLUSIONS: Digital fURSs were less effective in accessing the sharp angled calix and they had lesser end-tip deflection compared with the fiber-optic counterparts. When approaching a difficult lower pole calix, it might be better to use a fiber-optic fURS.

Entities:  

Keywords:  acute angled calices; end-tip deflection; flexible ureteroscopes

Mesh:

Year:  2017        PMID: 28478744     DOI: 10.1089/end.2017.0109

Source DB:  PubMed          Journal:  J Endourol        ISSN: 0892-7790            Impact factor:   2.942


  7 in total

Review 1.  Which flexible ureteroscope is the best for upper tract urothelial carcinoma treatment?

Authors:  Etienne Xavier Keller; Steeve Doizi; Luca Villa; Olivier Traxer
Journal:  World J Urol       Date:  2019-02-15       Impact factor: 4.226

2.  Operator-assisted vs self-achieved basketing during ureteroscopy: results from an in vitro preference study.

Authors:  Eugenio Ventimiglia; Sermsin Sindhubodee; Thomas Besombes; Felipe Pauchard; Francesca Quadrini; Bertrand Delbarre; Alvaro Jiménez Godínez; Yazeed Barghouthy; Mariela Alejandra Corrales Acosta; Hatem Kamkoum; Luca Villa; Steeve Doizi; Bhaskar K Somani; Olivier Traxer
Journal:  World J Urol       Date:  2020-10-06       Impact factor: 4.226

Review 3.  Reusable flexible ureterorenoscopes are more cost-effective than single-use scopes: results of a systematic review from PETRA Uro-group.

Authors:  Michele Talso; Ioannis K Goumas; Guido M Kamphuis; Laurian Dragos; Tzevat Tefik; Olivier Traxer; Bhaskar K Somani
Journal:  Transl Androl Urol       Date:  2019-09

Review 4.  Flexible ureteroscopy: technique, tips and tricks.

Authors:  Steeve Doizi; Olivier Traxer
Journal:  Urolithiasis       Date:  2017-12-08       Impact factor: 3.436

5.  Characteristics of current digital single-use flexible ureteroscopes versus their reusable counterparts: an in-vitro comparative analysis.

Authors:  Laurian B Dragos; Bhaskar K Somani; Etienne X Keller; Vincent M J De Coninck; Maria Rodriguez-Monsalve Herrero; Guido M Kamphuis; Ewa Bres-Niewada; Emre T Sener; Steeve Doizi; Oliver J Wiseman; Olivier Traxer
Journal:  Transl Androl Urol       Date:  2019-09

6.  LithoVue™ for renal stone therapy - a perfect fit for high volume academic centers; a retrospective evaluation of 108 cases.

Authors:  Maximilian Pallauf; Sabina Sevcenco; Christopher Steiner; Martin Drerup; Michael Mitterberger; Daniela Colleselli; Lukas Lusuardi; Thomas Kunit
Journal:  BMC Urol       Date:  2020-05-18       Impact factor: 2.264

7.  Italian endourological panorama: results from a national survey.

Authors:  Silvia Proietti; Bhaskar K Somani; Amelia Pietropaolo; Giuseppe Saitta; Moises Elias Rodríguez-Socarrás; Marco Rosso; Piera Bellinzoni; Franco Gaboardi; Guido Giusti
Journal:  Cent European J Urol       Date:  2018-03-27
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.