Literature DB >> 3165508

Radiobiologic risk estimation from dental radiology. Part I. Absorbed doses to critical organs.

T E Underhill1, I Chilvarquer, K Kimura, R P Langlais, W D McDavid, J W Preece, G Barnwell.   

Abstract

The aim of the present study was to generate one consistent set of data for evaluating and comparing radiobiologic risks from different dental radiographic techniques. To accomplish this goal, absorbed doses were measured in fourteen anatomic sites from (1) five different panoramic machines with the use of rare-earth screens, (2) a twenty-film complete-mouth survey with E-speed film, long round cone, (3) a twenty-film complete-mouth survey with E-speed film, long rectangular cone, (4) a four-film interproximal survey with E-speed film, long round cone, and (5) a four-film interproximal survey with E-speed film, long rectangular cone. The dose to the thyroid gland, the active bone marrow, the brain, and the salivary glands was evaluated by means of exposure of a tissue-equivalent phantom, fitted with lithium fluoride thermoluminescent dosimeters (TLDs) at the relevant locations.

Entities:  

Mesh:

Year:  1988        PMID: 3165508     DOI: 10.1016/0030-4220(88)90077-1

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol        ISSN: 0030-4220


  13 in total

1.  Pre-clinical evaluation of a new dental panoramic radiographic system based on tomosynthesis method.

Authors:  M Noujeim; T Prihoda; W D McDavid; K Ogawa; T Yamakawa; K Seki; T Okano; T Sue; R P Langlais
Journal:  Dentomaxillofac Radiol       Date:  2011-01       Impact factor: 2.419

2.  A manufacturer's role in reducing the dose of cone beam computed tomography examinations: effect of beam filtration.

Authors:  J B Ludlow
Journal:  Dentomaxillofac Radiol       Date:  2011-02       Impact factor: 2.419

3.  Assessment of the effective doses from two dental cone beam CT devices.

Authors:  R Schilling; M-A Geibel
Journal:  Dentomaxillofac Radiol       Date:  2013-02-18       Impact factor: 2.419

4.  Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomography.

Authors:  John B Ludlow; Cameron Walker
Journal:  Am J Orthod Dentofacial Orthop       Date:  2013-12       Impact factor: 2.650

5.  Kerma area product (KAP) and scatter measurements for intraoral X-ray machines using three different types of round collimation compared with rectangular beam limiter.

Authors:  Dennise Magill; Nhan James Huu Ngo; Marc A Felice; Mel Mupparapu
Journal:  Dentomaxillofac Radiol       Date:  2018-11-07       Impact factor: 2.419

6.  Thyroid Radiation Dose to Patients from Diagnostic Radiology Procedures over Eight Decades: 1930-2010.

Authors:  Lienard A Chang; Donald L Miller; Choonsik Lee; Dunstana R Melo; Daphnée Villoing; Vladimir Drozdovitch; Isabelle Thierry-Chef; Sarah J Winters; Michael Labrake; Charles F Myers; Hyeyeun Lim; Cari M Kitahara; Martha S Linet; Steven L Simon
Journal:  Health Phys       Date:  2017-12       Impact factor: 1.316

Review 7.  Effective dose of dental CBCT-a meta analysis of published data and additional data for nine CBCT units.

Authors:  J B Ludlow; R Timothy; C Walker; R Hunter; E Benavides; D B Samuelson; M J Scheske
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

8.  Evaluation of surface radiation dose to the thyroid gland and the gonads during routine full-mouth intraoral periapical and maxillary occlusal radiography.

Authors:  Soheyl Sheikh; Anil Kumar Bhoweer; Smriti Arya; Gagandeep Arora
Journal:  Contemp Clin Dent       Date:  2010-04

9.  Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT.

Authors:  Dae-Kyo Jeong; Sang-Chul Lee; Kyung-Hoe Huh; Won-Jin Yi; Min-Suk Heo; Sam-Sun Lee; Soon-Chul Choi
Journal:  Imaging Sci Dent       Date:  2012-06-25

Review 10.  Three-dimensional imaging techniques: A literature review.

Authors:  Orhan Hakki Karatas; Ebubekir Toy
Journal:  Eur J Dent       Date:  2014-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.