Literature DB >> 31641940

Anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual X-ray and 3D printing.

Jing Xu1, Guodong Zhang2, Zaopeng He3, Shizhen Zhong1, Yongshao Chen4, Chunrong Wei3, Yudong Zheng3, Haibin Lin5, Wei Li6, Wenhua Huang7.   

Abstract

To evaluate and precisely internal fix intra-articular distal radial fracture (IDRF) using the virtual X-ray and three-dimensional (3D) printing technologies. Twenty-one patients with IDRF were recruited, and the data from digital design group (DDG) and real surgery group (RSG) were collected and analyzed. In DDG, the data from thin-slice computed tomography scan, virtual X-ray measurement parameters, including volar tilt, palmar tilt, radius length (D1), ulnar variation (D2), locking plate position parameter (D3) and distance between key nail and joint surface (D4) were collected. The bone was virtually fixed with the locking plate, and the final model of radius with the screw was obtained by 3D printing. In RSG, the locking plate was precisely pre-bended and used in surgery. During the surgery, the key K-wire was accurately placed and the locking plate was adjusted with the aid of the U-shaped navigation arm. The C-arm was used to observe the positions of key K-wires and the locking plate, and the same above-mentioned parameters were measured intra- and post-operatively. The data from RSG and DDG were compared statistically by t test. This approach proved to be successful in all 21 patients, and none of the screws pierced through the wrist joint surface. All the measured parameters, including the volar tilt, palmar tilt, D1-4, in RSG were not significantly different from preoperative DDG data. Virtual X-ray measurement of anatomical reduction parameters and 3D printing can help the anatomical reduction and precise internal fixation by providing quantitative references, preoperatively, intraoperatively and postoperatively.

Entities:  

Keywords:  3D printing; Anatomical reduction; Distal radial fracture (DRF); Internal fixation; Intra-articular distal radial fracture (IDRF); Virtual X-ray

Year:  2019        PMID: 31641940      PMCID: PMC7026237          DOI: 10.1007/s13246-019-00795-w

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  39 in total

Review 1.  Systematic review of outcomes following fixed angle intramedullary fixation of distal radius fractures.

Authors:  John Hardman; Nawfal Al-Hadithy; Thomas Hester; Raymond Anakwe
Journal:  Int Orthop       Date:  2015-04-15       Impact factor: 3.075

2.  Fragment-specific volar hook plate for volar marginal rim fractures.

Authors:  Adam J Bakker; Alexander Y Shin
Journal:  Tech Hand Up Extrem Surg       Date:  2014-03

3.  Intra-articular distal radius fractures: Postoperative roentgenographic and functional outcomes.

Authors:  Muhammad Shahid Khan; Shahryar Noordin; Pervaiz Mehmood Hashmi
Journal:  J Pak Med Assoc       Date:  2016-03       Impact factor: 0.781

4.  Ulnar variance determination.

Authors:  S S Kristensen; E Thomassen; F Christensen
Journal:  J Hand Surg Br       Date:  1986-06

5.  Volar plate fixation failure for volar shearing distal radius fractures with small lunate facet fragments.

Authors:  John D Beck; Neil G Harness; Hillard T Spencer
Journal:  J Hand Surg Am       Date:  2014-03-06       Impact factor: 2.230

6.  Volar locking plate fixation versus external fixation of distal radius fractures: a meta-analysis.

Authors:  Conor J C Gouk; Randip R Bindra; Drew J Tarrant; Michael J E Thomas
Journal:  J Hand Surg Eur Vol       Date:  2017-12-11

7.  Technical tips for (dry) arthroscopic reduction and internal fixation of distal radius fractures.

Authors:  Francisco Del Piñal
Journal:  J Hand Surg Am       Date:  2011-10       Impact factor: 2.230

8.  Long-term outcome of nonsurgically treated distal radius fractures.

Authors:  Zoltan Földhazy; Hans Törnkvist; Erik Elmstedt; Gunilla Andersson; Birgit Hagsten; Leif Ahrengart
Journal:  J Hand Surg Am       Date:  2007-11       Impact factor: 2.230

9.  A normal data base of posteroanterior roentgenographic measurements of the wrist.

Authors:  F A Schuind; R L Linscheid; K N An; E Y Chao
Journal:  J Bone Joint Surg Am       Date:  1992-10       Impact factor: 5.284

10.  Comparing the effect of volar plate fixators and external fixators on outcome of patients with intra-articular distal radius fractures: A clinical trial.

Authors:  Mohammadreza Safdari; Mahmoodreza Mohajer Koohestani
Journal:  Electron Physician       Date:  2015-06-05
View more
  1 in total

1.  A modified intrafocal pinning technique with three-dimensional planning to facilitate volar plating in dorsally comminuted AO/OTA C2 and C3 distal radius fractures.

Authors:  Xue-Yang Gui; Hong-Fei Shi; Jin Xiong; Yi-Xin Chen; Jun-Fei Wang; Jie Huang; Xu-Sheng Qiu; Yin-He Wang
Journal:  BMC Musculoskelet Disord       Date:  2021-04-23       Impact factor: 2.362

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.