Literature DB >> 26968276

Intra-articular distal radius fractures: Postoperative roentgenographic and functional outcomes.

Muhammad Shahid Khan1, Shahryar Noordin1, Pervaiz Mehmood Hashmi1.   

Abstract

OBJECTIVE: To assess the outcome of volarlocking compression plate fixation for intra-articular distal radius fractures with respect to function of hand and roentgenographic parameters.
METHODS: The retrospective study was conducted at the Aga Khan University Hospital, Karachi, and comprised patients who underwent locking compression plate fixation for intra-articular distal radius fractures between June 2009 and July 2012. Case notes, radiographic assessment and functional outcomes were noted. Functional outcome was determined with the help of telephone-based quick-dash score questionnaire administered atleast 6 months post-surgery. Radiological assessment of radial inclination, radial height and volar tilt was measured on immediate postoperative radiographs and then again measured at last available follow-up which ranged from 4 to 116 weeks.
RESULTS: The mean age of the 43 patients in the study was 47.31±14.24 years (range: 20-95 years) at the time of injury. Mean Quick Dash score at 6-month follow-up was 17.2±8.8 (range: 4-40). The outcome was very good in 1(2.2%), good in 30(66.7%), satisfactory in 10(22.2%) and poor in 4(8.9%) patients. Mean immediate postoperative radial inclination, volar tilt and radial height were 17.26±3.23°, 7.6±3.87° and 10.2±1.95mm respectively. Corresponding values at the last follow-up were 17±3.89°, 7.67±4.28° and 9.8±1.8mm.
CONCLUSIONS: Use of locking compression plate for intra-articular distal radius fracture showed good results comparable with global literature.

Entities:  

Keywords:  Distal radius fracture, Locking compression plate, Outcome.

Mesh:

Year:  2016        PMID: 26968276

Source DB:  PubMed          Journal:  J Pak Med Assoc        ISSN: 0030-9982            Impact factor:   0.781


  3 in total

1.  Distinct Wrist Patterns Founded on Measurements in Plain Radiographs.

Authors:  Aviv Kramer; Raviv Allon; Frederick Werner; Idit Lavi; Alon Wolf; Ronit Wollstein
Journal:  J Wrist Surg       Date:  2018-06-17

2.  Radiological Outcomes of Distal Radius Fractures Managed with 2.7mm Volar Locking Plate Fixation-A Retrospective Analysis.

Authors:  Prem Kotian; Srikanth Mudiganty; Rajendra Annappa; Jose Austine
Journal:  J Clin Diagn Res       Date:  2017-01-01

3.  Anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual X-ray and 3D printing.

Authors:  Jing Xu; Guodong Zhang; Zaopeng He; Shizhen Zhong; Yongshao Chen; Chunrong Wei; Yudong Zheng; Haibin Lin; Wei Li; Wenhua Huang
Journal:  Australas Phys Eng Sci Med       Date:  2019-10-22       Impact factor: 1.430

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.