Literature DB >> 25876227

Systematic review of outcomes following fixed angle intramedullary fixation of distal radius fractures.

John Hardman1, Nawfal Al-Hadithy2, Thomas Hester3, Raymond Anakwe2.   

Abstract

PURPOSE: There remains little consensus regarding the optimal management of distal radius fractures. Fixed angle volar devices have gained recent popularity, but have also been associated with soft tissue complications. Intramedullary (IM) devices offer fixed angle stabilisation with minimally invasive surgical technique and low, IM profile. No formal review of outcomes could be identified.
METHODS: We conducted a systematic review of clinical studies regarding the use of fixed angle IM devices in acute extra-articular or simple intra-articular distal radius fractures. Preferred Reporting Items for Systematic Reviews (PRISMA) guidance was followed. Numerical data regarding functional scores, ranges of movement, radiological outcomes and complications were pooled to produce aggregate means and standard deviation.
RESULTS: A total of 310 titles and abstracts were identified. Fourteen papers remained for analysis. Total patient number was 357, mean age 63.72 years and mean follow-up 12.77 months. Mean functional scores were all rated as 'excellent'. Aggregate means: flexion 53.62°, extension 56.38°, pronation 69.10°, supination 70.29°, ulnar deviation 28.35°, radial deviation 18.12°, radial height 8.98 mm, radial inclination 16.51°, volar tilt 5.35°, ulnar variance 0.66 mm and grip strength 90.37 %. Overall complication rate was 19.6 %. Tendon rupture was unreported. Tendon irritation was 0.88 %. Radial nerve paraesthesia was 11.44 %.
CONCLUSIONS: Fixed angle IM devices facilitate excellent functional outcomes, with radiological and clinical parameters at least equivalent to volar plate devices. Low rates of tendon irritation and absence of tendon rupture are advantageous. Significant limitations include a lack of application for complex articular injuries and the propensity to cause a transient neuritis of the superficial branch of the radial nerve.

Entities:  

Keywords:  Distal radius fracture; Intramedullary fixation; Systematic review; Tendon rupture

Mesh:

Year:  2015        PMID: 25876227     DOI: 10.1007/s00264-015-2763-1

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  35 in total

Review 1.  What are the radiological predictors of functional outcome following fractures of the distal radius?

Authors:  C Y Ng; M M McQueen
Journal:  J Bone Joint Surg Br       Date:  2011-02

2.  Evaluation of healed Colles' fractures.

Authors:  J J GARTLAND; C W WERLEY
Journal:  J Bone Joint Surg Am       Date:  1951-10       Impact factor: 5.284

3.  Locked volar plating for unstable distal radial fractures: clinical and radiological outcomes.

Authors:  Dominique Knight; Carol Hajducka; Elizabeth Will; Margaret McQueen
Journal:  Injury       Date:  2009-10-12       Impact factor: 2.586

4.  The operative treatment of fractures of the distal radius is increasing: results from a nationwide Swedish study.

Authors:  C Mellstrand-Navarro; H J Pettersson; H Tornqvist; S Ponzer
Journal:  Bone Joint J       Date:  2014-07       Impact factor: 5.082

5.  Minimally invasive flexible insertion and rigid intramedullary nail fixation for distal radius fractures.

Authors:  Peter C Rhee; Alexander Y Shin
Journal:  Tech Hand Up Extrem Surg       Date:  2012-09

6.  Colles fracture: does the anatomical result affect the final function?

Authors:  M McQueen; J Caspers
Journal:  J Bone Joint Surg Br       Date:  1988-08

7.  Current and future national costs to medicare for the treatment of distal radius fracture in the elderly.

Authors:  Melissa J Shauver; Huiying Yin; Mousumi Banerjee; Kevin C Chung
Journal:  J Hand Surg Am       Date:  2011-06-25       Impact factor: 2.230

8.  Patient-perceived outcome after displaced distal radius fractures. A comparison between radiological parameters, objective physical variables, and the DASH score.

Authors:  Maria K T Wilcke; Hassan Abbaszadegan; Per Y Adolphson
Journal:  J Hand Ther       Date:  2007 Oct-Dec       Impact factor: 1.950

9.  Treatment of extra-articular and simple articular distal radial fractures with intramedullary nail versus volar locking plate.

Authors:  A Safi; R Hart; B Těknědžjan; T Kozák
Journal:  J Hand Surg Eur Vol       Date:  2013-02-26

10.  Type C distal radial fractures treated with conventional AO plates: an easy and cost-saving solution in a locking plate era.

Authors:  Bas Twigt; Michael Bemelman; Koen Lansink; Loek Leenen
Journal:  Int Orthop       Date:  2013-01-11       Impact factor: 3.075

View more
  7 in total

Review 1.  Intramedullary nail versus volar locking plate fixation for the treatment of extra-articular or simple intra-articular distal radius fractures: systematic review and meta-analysis.

Authors:  Bing Zhang; Hengrui Chang; Kunlun Yu; Jiangbo Bai; Dehu Tian; Guisheng Zhang; Xinzhong Shao; Yingze Zhang
Journal:  Int Orthop       Date:  2017-04-07       Impact factor: 3.075

2.  Anatomical reduction and precise internal fixation of intra-articular fractures of the distal radius with virtual X-ray and 3D printing.

Authors:  Jing Xu; Guodong Zhang; Zaopeng He; Shizhen Zhong; Yongshao Chen; Chunrong Wei; Yudong Zheng; Haibin Lin; Wei Li; Wenhua Huang
Journal:  Australas Phys Eng Sci Med       Date:  2019-10-22       Impact factor: 1.430

3.  Efficiency of fragment specific fixation plates in the treatment of comminuted distal radial fractures.

Authors:  Elhadi Musaab Elhadi Babikir; Eyad Daood Al-Maqdassy; Khalid Hasan; Shamsi Abdul Hameed; Abduljabbar Alhammoud; Mohammed Mubarak Al-Ateeq Al-Dosari
Journal:  Int Orthop       Date:  2017-06-27       Impact factor: 3.075

4.  Functional and radiological outcome of distal radius fractures stabilized by volar-locking plate with a minimum follow-up of 1 year.

Authors:  Stefan Quadlbauer; Ch Pezzei; J Jurkowitsch; R Rosenauer; A Pichler; S Schättin; T Hausner; M Leixnering
Journal:  Arch Orthop Trauma Surg       Date:  2020-03-27       Impact factor: 3.067

5.  Intramedullary Fixation of Distal Radius Fractures Using CAGE-DR Implant.

Authors:  Schneider K Rancy; Stephanie D Malliaris; Eric A Bogner; Scott W Wolfe
Journal:  J Wrist Surg       Date:  2018-09-18

6.  Fixation of unstable distal radius fractures by using expandable Intramedullary nailing system in adult patients.

Authors:  Murat Calbiyik
Journal:  Pak J Med Sci       Date:  2018 Jan-Feb       Impact factor: 1.088

7.  Outcome after treatment of distal radius fractures in the elderly using the IlluminOss® System.

Authors:  Guido W Van Oijen; Paul A Vegt; Tjebbe Hagenaars; Esther M M Van Lieshout; Michael H J Verhofstad
Journal:  Eur J Trauma Emerg Surg       Date:  2020-01-16       Impact factor: 3.693

  7 in total