| Literature DB >> 31614953 |
Xingning Xiao1,2, Wen Wang3, Jianmin Zhang4, Ming Liao5, Hua Yang6, Weihuan Fang7, Yanbin Li8,9.
Abstract
: The study was to establish a predictive model for reduction and cross-contamination of Salmonella on chicken in chilling process. Reduction of Salmonella on chicken was 0.75 ± 0.04, 0.74 ± 0.08, and 0.79 ± 0.07 log CFU/g with 20, 50, and 100 mg/L of chlorine, respectively. No significant differences of bacterial reductions with 20-100 mg/L of chlorine were found and a Normal (-0.75, 0.1) distribution could describe the uncertainty of bacterial reductions. Inoculated and non-inoculated chicken samples were washed together and bacterial transfer rates among them were 0.13%-0.004% with 20-100 mg/L of chlorine. No significant differences of transfer rates with 50-100 mg/L of chlorine were observed and a Triangle (-2.5, -1.5, -1.1) distribution could describe the log transfer rate. Additionally, a 3-factor response surface model based on the central composite design was developed to evaluate the effects of initial contamination level (1-5 log CFU/g), pre-chill incidence (3%-40%) and chlorine concentration (0-100 mg/L) on post-chill incidence. The post-chill incidences in these treatments were within 30%-91.7%. The developed model showed a satisfactory performance to predict the post-chill incidence as evidenced by statistical indices (pseudo-R2 = 0.9; p < 0.0001; RMSE = 0.21) and external validation parameters (Bf = 1.02; Af = 1.11).Entities:
Keywords: Salmonella; cross-contamination; modeling; poultry chilling; reduction
Year: 2019 PMID: 31614953 PMCID: PMC6843316 DOI: 10.3390/microorganisms7100448
Source DB: PubMed Journal: Microorganisms ISSN: 2076-2607
Levels of variables in the experiment.
| Variable | Range | Level | ||||
|---|---|---|---|---|---|---|
| −α | −1 | 0 | 1 |
| ||
| Initial contamination level (log CFU/g) | 1–5 | 1 | 2 | 3 | 4 | 5 |
| Pre-chill incidence (%) | 3–40 | 3 | 10.2 | 21.5 | 32.8 | 40 |
| Chlorine (mg/L) | 0–100 | 0 | 20 | 50 | 80 | 100 |
Experimental design and post-chill incidence of Salmonella in chilling process.
| Run | Initial Contamination Level | Pre-Chill Incidence | Chlorine | a Post-Chill Incidence |
|---|---|---|---|---|
| 1 | 2 | 32.8 | 80 | 43.3 ± 14.1 |
| 2 | 4 | 10.2 | 80 | 66. 7 ± 4.7 |
| 3 | 3 | 21.5 | 50 | 65 ± 2.4 |
| 4 | 2 | 10.2 | 20 | 40 ± 12.4 |
| 5 | 3 | 21.5 | 50 | 68.4 ± 11.8 |
| 6 | 4 | 32.8 | 20 | 91.7 ± 7.1 |
| 7 | 3 | 21.5 | 50 | 65 ± 11.8 |
| 8 | 4 | 32.8 | 80 | 85 ± 2.4 |
| 9 | 2 | 10.2 | 80 | 35 ± 7.1 |
| 10 | 2 | 32.8 | 20 | 60 ± 28.3 |
| 11 | 3 | 21.5 | 50 | 70 ± 14.1 |
| 12 | 4 | 10.2 | 20 | 90 ± 9.4 |
| 13 | 3 | 21.5 | 0 | 81.7 ± 21.2 |
| 14 | 3 | 40 | 50 | 78.4 ± 25.9 |
| 15 | 5 | 21.5 | 50 | 90 ± 4.7 |
| 16 | 3 | 21.5 | 50 | 65 ± 4.7 |
| 17 | 3 | 3 | 50 | 40 ± 18.9 |
| 18 | 3 | 21.5 | 100 | 65 ± 2.4 |
| 19 | 3 | 21.5 | 50 | 63.3 ± 4.7 |
| 20 | 1 | 21.5 | 50 | 30 ± 4.7 |
a Values are means ± standard deviations (n = 2). Values followed by different superscript letters are significantly different (p < 0.05).
Eight independent trials to validate the model for post-chill incidence in chilling process.
| Run | Initial Contamination Level (log CFU/g) | Pre-Chill Incidence (%) | Chlorine (mg/L) | Post-Chill Incidence (%) | |
|---|---|---|---|---|---|
| Observed | Predicted | ||||
| 1 | 3 | 12.5 | 10 | 62.5 ± 8.8 | 69.1 |
| 2 | 3 | 37.5 | 10 | 100.0 ± 0.0 | 88.0 |
| 3 | 3 | 12.5 | 70 | 50.0 ± 0.0 | 52.0 |
| 4 | 3 | 37.5 | 70 | 87.5 ± 8.8 | 71.0 |
| 5 | 5 | 12.5 | 10 | 100.0 ± 0.0 | 100.6 |
| 6 | 5 | 37.5 | 10 | 100.0 ± 0.0 | 119.5 |
| 7 | 5 | 12.5 | 70 | 100.0 ± 0.0 | 83.5 |
| 8 | 5 | 37.5 | 70 | 100.0 ± 0.0 | 102.5 |
Figure 1Bacterial reductions of Salmonella on chicken breasts with 20 (◆), 50 (■) and 100 (▲) mg/L of chlorine.
Figure 2Probability distribution of Salmonella reduction on chicken breasts in chilling water with 20–100 mg/L of chlorine.
Figure 3Probability distribution of transfer rate (log%) among chicken breasts in chilling water with 50–100 mg/L of chlorine.
The estimated parameters for variables with significance.
| Factor | Value | Standard Error | Prob > |
|---|---|---|---|
| Intercept | 92.0 | 3.3 | |
|
| 31.0 | 2.8 | < 0.0001 ** |
|
| 13.6 | 2.8 | 0.0002 * |
|
| −9.7 | 2.8 | 0.004 * |
|
| 10.8 | 4.6 | 0.03 * |
Asterisks indicate statistical significance by F test (** p < 0.0001; * p < 0.05).
Figure 4Response surface plots describing the effect of initial contamination level and pre-chill incidence (A); initial contamination level and chlorine concentration (B); and pre-chill incidence and chlorine concentration (C) on post-chill incidence of Salmonella in chilling process.
Changes in the color of chicken breasts treated with different chlorine concentrations.
| Chlorine (mg/L) | Δ | Δ | Δ | Δ |
|---|---|---|---|---|
| 0 | 5.4 ± 1.0 | 1.4 ± 0.4 | 3.3 ± 0.9 | 6.5 |
| 20 | 7.0 ± 1.9 | 2.2 ± 0.9 | 1.6 ± 0.7 | 7.5 |
| 50 | 5.6 ± 1.6 | 0.8 ± 0.9 | 2.8 ± 1.6 | 6.3 |
| 100 | 5.5 ± 2.2 | 1.7 ± 1.0 | 2.8 ± 1.4 | 6.4 |
Mean values followed by different superscript letters are significantly different (p < 0.05).
Figure 5TEM images of Salmonella treated with 0 (A), 50 (B), and 100 mg/L (C) of chlorine.