Literature DB >> 31607445

Ultrahigh-Performance capillary liquid chromatography-mass spectrometry at 35 kpsi for separation of lipids.

Matthew J Sorensen1, Kelsey E Miller2, James W Jorgenson2, Robert T Kennedy3.   

Abstract

Improvements in sample preparation, separation, and mass spectrometry continue to expand the coverage in LC-MS based lipidomics. While longer columns packed with smaller particles in theory give higher separation performance compared to shorter columns, the implementation of this technology above commercial limits has been sparse due to difficulties in packing long columns and successfully operating instruments at ultrahigh pressures. In this work, a liquid chromatograph that operates up to 35 kpsi was investigated for the separation and identification of lipid species from human plasma. Capillary columns between 15-50 cm long were packed with 1.7 µm BEH C18 particles and evaluated for their ability to separate lipid isomers and complex lipid extracts from human plasma. Putative lipid class identifications were assigned using accurate mass and relative retention time data of the eluting peaks. Our findings indicate that longer columns packed and operated at 35 kpsi outperform shorter columns packed and run at lower pressures in terms of peak capacity and numbers of features identified. Packing columns with relatively high concentration slurries (200 mg/mL) while sonicating the column resulted in 6-34% increase in peak capacity for 50 cm columns compared to lower slurry concentrations and no sonication. For a given analysis time, 50 cm long columns operated at 35 kpsi provided a 20-95% increase in chromatographic peak capacity compared with 15 cm columns operated at 15 kpsi. Analysis times up to 4 h were evaluated, generating peak capacities up to 410 ± 5 (n = 3, measured at 4σ) and identifying 480 ± 85 lipids (n = 2). Importantly, the results also show a correlation between the peak capacity and the number of lipids identified from a human plasma extract. This correlation indicates that ionization suppression is a limiting factor in obtaining sufficient signal for identification by mass spectrometry. The result also shows that the higher resolution obtained by shallow gradients overcomes possible signal reduction due to broader, more dilute peaks in long gradients for improving detection of lipids in LC-MS. Lastly, longer columns operated at shallow gradients allowed for the best separation of both regional and geometrical isomers. These results demonstrate a system that enables the advantages of using longer columns packed and run at ultrahigh pressure for improving lipid separations and lipidome coverage.
Copyright © 2019. Published by Elsevier B.V.

Entities:  

Keywords:  Capillary chromatography; LC–MS; Lipid isomers; Lipidomics; UHPLC

Mesh:

Substances:

Year:  2019        PMID: 31607445      PMCID: PMC6980658          DOI: 10.1016/j.chroma.2019.460575

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  39 in total

1.  Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: when does ESI turn into nano-ESI?

Authors:  Andrea Schmidt; Michael Karas; Thomas Dülcks
Journal:  J Am Soc Mass Spectrom       Date:  2003-05       Impact factor: 3.109

2.  Automated 20 kpsi RPLC-MS and MS/MS with chromatographic peak capacities of 1000-1500 and capabilities in proteomics and metabolomics.

Authors:  Yufeng Shen; Rui Zhang; Ronald J Moore; Jeongkwon Kim; Thomas O Metz; Kim K Hixson; Rui Zhao; Eric A Livesay; Harold R Udseth; Richard D Smith
Journal:  Anal Chem       Date:  2005-05-15       Impact factor: 6.986

3.  Peak capacity optimization of peptide separations in reversed-phase gradient elution chromatography: fixed column format.

Authors:  Xiaoli Wang; Dwight R Stoll; Adam P Schellinger; Peter W Carr
Journal:  Anal Chem       Date:  2006-05-15       Impact factor: 6.986

Review 4.  Capillary electrophoresis-based methods for the determination of lipids--a review.

Authors:  Anthony C Otieno; Simon M Mwongela
Journal:  Anal Chim Acta       Date:  2008-06-26       Impact factor: 6.558

5.  Slurry concentration effects on the bed morphology and separation efficiency of capillaries packed with sub-2 μm particles.

Authors:  Stefan Bruns; Edward G Franklin; James P Grinias; Justin M Godinho; James W Jorgenson; Ulrich Tallarek
Journal:  J Chromatogr A       Date:  2013-11-29       Impact factor: 4.759

6.  Nano-LC/NSI MS Refines Lipidomics by Enhancing Lipid Coverage, Measurement Sensitivity, and Linear Dynamic Range.

Authors:  Niklas Danne-Rasche; Cristina Coman; Robert Ahrends
Journal:  Anal Chem       Date:  2018-06-11       Impact factor: 6.986

Review 7.  Bioinformatics and systems biology of the lipidome.

Authors:  Shankar Subramaniam; Eoin Fahy; Shakti Gupta; Manish Sud; Robert W Byrnes; Dawn Cotter; Ashok Reddy Dinasarapu; Mano Ram Maurya
Journal:  Chem Rev       Date:  2011-09-23       Impact factor: 60.622

8.  On the feasibility to conduct gradient liquid chromatography separations in narrow-bore columns at pressures up to 2000bar.

Authors:  Ruben De Pauw; Tim Swier; Bart Degreef; Gert Desmet; Ken Broeckhoven
Journal:  J Chromatogr A       Date:  2016-10-06       Impact factor: 4.759

Review 9.  Lipidomics applications for discovering biomarkers of diseases in clinical chemistry.

Authors:  Ying-Yong Zhao; Xian-long Cheng; Rui-Chao Lin
Journal:  Int Rev Cell Mol Biol       Date:  2014       Impact factor: 6.813

10.  Shorthand notation for lipid structures derived from mass spectrometry.

Authors:  Gerhard Liebisch; Juan Antonio Vizcaíno; Harald Köfeler; Martin Trötzmüller; William J Griffiths; Gerd Schmitz; Friedrich Spener; Michael J O Wakelam
Journal:  J Lipid Res       Date:  2013-04-02       Impact factor: 5.922

View more
  5 in total

Review 1.  Nano-liquid chromatography-mass spectrometry and recent applications in omics investigations.

Authors:  Katherine L Sanders; James L Edwards
Journal:  Anal Methods       Date:  2020-09-09       Impact factor: 2.896

2.  Liquid chromatography above 20,000 PSI.

Authors:  Matthew J Sorensen; Brady G Anderson; Robert T Kennedy
Journal:  Trends Analyt Chem       Date:  2020-01-21       Impact factor: 12.296

3.  Improved Sensitivity of Ultralow Flow LC-MS-Based Proteomic Profiling of Limited Samples Using Monolithic Capillary Columns and FAIMS Technology.

Authors:  Michal Greguš; James C Kostas; Somak Ray; Susan E Abbatiello; Alexander R Ivanov
Journal:  Anal Chem       Date:  2020-10-15       Impact factor: 6.986

4.  Comparison of microcapillary column length and inner diameter investigated with gradient analysis of lipids by ultrahigh-pressure liquid chromatography-mass spectrometry.

Authors:  Kelsey E Miller; James W Jorgenson
Journal:  J Sep Sci       Date:  2020-10-07       Impact factor: 3.645

5.  Multi-Omic Single-Shot Technology for Integrated Proteome and Lipidome Analysis.

Authors:  Yuchen He; Edrees H Rashan; Vanessa Linke; Evgenia Shishkova; Alexander S Hebert; Adam Jochem; Michael S Westphall; David J Pagliarini; Katherine A Overmyer; Joshua J Coon
Journal:  Anal Chem       Date:  2021-02-22       Impact factor: 6.986

  5 in total