Literature DB >> 31605141

OCCUPATIONAL RADIATION EXPOSURE DOSE OF THE EYE IN DEPARTMENT OF CARDIAC ARRHYTHMIA PHYSICIAN.

Mamoru Kato1,2, Koichi Chida2, Takato Ishida1, Fumiaki Sasaki1, Hideto Toyoshima1, Hajime Oosaka1, Ken Terata3, Yoshihisa Abe3, Toshibumi Kinoshita1.   

Abstract

Interventional radiology (IR) procedures tend to be complex, which delivers high radiation exposure to patient. In the present study, we measured the radiation exposure dose [Hp(3)] in the eye using a direct eye dosemeter placed next to the physician's eye during procedures. Physicians wore a direct eye dosemeter just lateral to eyes and an additional direct eye dosemeter outside the radiation protective eyeglasses close to their eyes. Additionally, a neck glass badge was worn at the neck. Although we found a positive correlation between the left neck glass badge dose [Hp(0.07)] and the left eye lens dose [Hp(3)], the value of R2 of the regression equation were 0.62 and 0.71 (outside and inside). We thought that the exact eye lens dose might not be estimated from the neck glass badge. In conclusion, a correct evaluation of the lens dose [Hp(3)] using the direct eye dosemeter is recommended for tachyarrhythmia physicians.
© The Author(s) 2019. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Year:  2019        PMID: 31605141     DOI: 10.1093/rpd/ncz175

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  Evaluation of novel X-ray protective eyewear in reducing the eye dose to interventional radiology physicians.

Authors:  Mime Endo; Yoshihiro Haga; Masahiro Sota; Akiko Tanaka; Kazuki Otomo; Yuuki Murabayashi; Mitsuya Abe; Yuji Kaga; Yohei Inaba; Msatoshi Suzuki; Taiichiro Meguro; Koichi Chida
Journal:  J Radiat Res       Date:  2021-05-12       Impact factor: 2.724

Review 2.  What are useful methods to reduce occupational radiation exposure among radiological medical workers, especially for interventional radiology personnel?

Authors:  Koichi Chida
Journal:  Radiol Phys Technol       Date:  2022-05-24

3.  Radiation Eye Dose for Physicians in CT Fluoroscopy-Guided Biopsy.

Authors:  Yohei Inaba; Shin Hitachi; Munenori Watanuki; Koichi Chida
Journal:  Tomography       Date:  2022-02-08

4.  Development of a New Radiation Shield for the Face and Neck of IVR Physicians.

Authors:  Toshimitsu Sato; Yoichi Eguchi; Chika Yamazaki; Takanobu Hino; Toshikazu Saida; Koichi Chida
Journal:  Bioengineering (Basel)       Date:  2022-07-29

5.  Radiation eye dose to medical staff during respiratory endoscopy under X-ray fluoroscopy.

Authors:  Yoshihiro Haga; Koichi Chida; Yuichiro Kimura; Shinsuke Yamanda; Masahiro Sota; Mitsuya Abe; Yuji Kaga; Taiichiro Meguro; Masayuki Zuguchi
Journal:  J Radiat Res       Date:  2020-09-08       Impact factor: 2.724

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.