Literature DB >> 31603828

Cuffless Blood Pressure Monitoring from an Array of Wrist Bio-Impedance Sensors Using Subject-Specific Regression Models: Proof of Concept.

Bassem Ibrahim, Roozbeh Jafari.   

Abstract

Continuous and beat-to-beat monitoring of blood pressure (BP), compared to office-based BP measurement, provides significant advantages in predicting future cardiovascular disease. Traditional BP measurement methods are based on a cuff, which is bulky, obtrusive and not applicable to continuous monitoring. Measurement of pulse transit time (PTT) is one of the prominent cuffless methods for continuous BP monitoring. PTT is the time taken by the pressure pulse to travel between two points in an arterial vessel, which is correlated with the BP. In this paper, we present a new cuffless BP method using an array of wrist-worn bio-impedance sensors placed on the radial and the ulnar arteries of the wrist to monitor the arterial pressure pulse from the blood volume changes at each sensor site. BP is accurately estimated by using AdaBoost regression model based on selected arterial pressure pulse features such as transit time, amplitude and slope of the pressure pulse, which are dependent on the cardiac activity and the vascular properties of the wrist arteries. A separate model is developed for each subject based on calibration data to capture the individual variations of BP parameters. In this pilot study, data was collected from 10 healthy participants with age ranges from 18 to 30 years after exercising using our custom low-noise bio-impedance sensing hardware. Post-exercise BP was accurately estimated with an average correlation coefficient and root mean square error (RMSE) of 0.77 and 2.6 mmHg for the diastolic BP and 0.86 and 3.4 mmHg for the systolic BP.

Entities:  

Mesh:

Year:  2019        PMID: 31603828      PMCID: PMC7028300          DOI: 10.1109/TBCAS.2019.2946661

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  24 in total

1.  Cuffless estimation of systolic blood pressure for short effort bicycle tests: the prominent role of the pre-ejection period.

Authors:  J Muehlsteff; X L Aubert; M Schuett
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

2.  Cuff-less and noninvasive measurements of arterial blood pressure by pulse transit time.

Authors:  C C Y Poon; Y T Zhang
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2005

3.  BioWatch: A Noninvasive Wrist-Based Blood Pressure Monitor That Incorporates Training Techniques for Posture and Subject Variability.

Authors:  Simi Susan Thomas; Viswam Nathan; Chengzhi Zong; Karthikeyan Soundarapandian; Xiangrong Shi; Roozbeh Jafari
Journal:  IEEE J Biomed Health Inform       Date:  2015-07-20       Impact factor: 5.772

4.  A Novel Continuous Blood Pressure Estimation Approach Based on Data Mining Techniques.

Authors:  Fen Miao; Nan Fu; Yuan-Ting Zhang; Xiao-Rong Ding; Xi Hong; Qingyun He; Ye Li
Journal:  IEEE J Biomed Health Inform       Date:  2017-04-28       Impact factor: 5.772

5.  Multi-Wavelength Photoplethysmography Enabling Continuous Blood Pressure Measurement With Compact Wearable Electronics.

Authors:  Jing Liu; Bryan P Yan; Yuan-Ting Zhang; Xiao-Rong Ding; Peng Su; Ni Zhao
Journal:  IEEE Trans Biomed Eng       Date:  2018-10-09       Impact factor: 4.538

6.  Cuffless Blood Pressure Estimation Algorithms for Continuous Health-Care Monitoring.

Authors:  Mohammad Kachuee; Mohammad Mahdi Kiani; Hoda Mohammadzade; Mahdi Shabany
Journal:  IEEE Trans Biomed Eng       Date:  2016-06-14       Impact factor: 4.538

7.  Continuous Blood Pressure Monitoring using Wrist-worn Bio-impedance Sensors with Wet Electrodes.

Authors:  Bassem Ibrahim; Roozbeh Jafari
Journal:  IEEE Biomed Circuits Syst Conf       Date:  2018-12-24

8.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

9.  Comparison of nonlinear methods symbolic dynamics, detrended fluctuation, and Poincare plot analysis in risk stratification in patients with dilated cardiomyopathy.

Authors:  Andreas Voss; Rico Schroeder; Sandra Truebner; Matthias Goernig; Hans Reiner Figulla; Alexander Schirdewan
Journal:  Chaos       Date:  2007-03       Impact factor: 3.642

10.  Monitoring of the central blood pressure waveform via a conformal ultrasonic device.

Authors:  Chonghe Wang; Xiaoshi Li; Hongjie Hu; Lin Zhang; Zhenlong Huang; Muyang Lin; Zhuorui Zhang; Zhenan Yin; Brady Huang; Hua Gong; Shubha Bhaskaran; Yue Gu; Mitsutoshi Makihata; Yuxuan Guo; Yusheng Lei; Yimu Chen; Chunfeng Wang; Yang Li; Tianjiao Zhang; Zeyu Chen; Albert P Pisano; Liangfang Zhang; Qifa Zhou; Sheng Xu
Journal:  Nat Biomed Eng       Date:  2018-09-11       Impact factor: 25.671

View more
  14 in total

1.  Boosted-SpringDTW for Comprehensive Feature Extraction of PPG Signals.

Authors:  Jonathan Martinez; Kaan Sel; Bobak J Mortazavi; Roozbeh Jafari
Journal:  IEEE Open J Eng Med Biol       Date:  2022-05-12

Review 2.  Cuffless Blood Pressure Monitoring: Academic Insights and Perspectives Analysis.

Authors:  Shiyun Li; Can Zhang; Zhirui Xu; Lihua Liang; Ye Tian; Long Li; Huaping Wu; Sheng Zhong
Journal:  Micromachines (Basel)       Date:  2022-07-30       Impact factor: 3.523

3.  A Meta-Learning Approach for Fast Personalization of Modality Translation Models in Wearable Physiological Sensing.

Authors:  Ali Akbari; Jonathan Martinez; Roozbeh Jafari
Journal:  IEEE J Biomed Health Inform       Date:  2022-04-14       Impact factor: 7.021

4.  The B-Score is a novel metric for measuring the true performance of blood pressure estimation models.

Authors:  Tomas L Bothe; Andreas Patzak; Niklas Pilz
Journal:  Sci Rep       Date:  2022-07-16       Impact factor: 4.996

5.  FPGA-Based Processor for Continual Capacitive-Coupling Impedance Spectroscopy and Circuit Parameter Estimation.

Authors:  Akihiko Tsukahara; Tomiharu Yamaguchi; Yuho Tanaka; Akinori Ueno
Journal:  Sensors (Basel)       Date:  2022-06-10       Impact factor: 3.847

6.  Cuffless and Touchless Measurement of Blood Pressure from Ballistocardiogram Based on a Body Weight Scale.

Authors:  Shing-Hong Liu; Bing-Hao Zhang; Wenxi Chen; Chun-Hung Su; Chiun-Li Chin
Journal:  Nutrients       Date:  2022-06-20       Impact factor: 6.706

7.  A Survey of Challenges and Opportunities in Sensing and Analytics for Risk Factors of Cardiovascular Disorders.

Authors:  Nathan C Hurley; Erica S Spatz; Harlan M Krumholz; Roozbeh Jafari; Bobak J Mortazavi
Journal:  ACM Trans Comput Healthc       Date:  2020-12-30

8.  Pulse Wave Modeling Using Bio-Impedance Simulation Platform Based on a 3D Time-Varying Circuit Model.

Authors:  Bassem Ibrahim; Drew A Hall; Roozbeh Jafari
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2021-03-30       Impact factor: 3.833

9.  Developing Personalized Models of Blood Pressure Estimation from Wearable Sensors Data Using Minimally-trained Domain Adversarial Neural Networks.

Authors:  Lida Zhang; Nathan C Hurley; Bassem Ibrahim; Erica Spatz; Harlan M Krumholz; Roozbeh Jafari; Bobak J Mortazavi
Journal:  Proc Mach Learn Res       Date:  2020-08

10.  A Revised Point-to-Point Calibration Approach with Adaptive Errors Correction to Weaken Initial Sensitivity of Cuff-Less Blood Pressure Estimation.

Authors:  Jiang Shao; Ping Shi; Sijung Hu; Hongliu Yu
Journal:  Sensors (Basel)       Date:  2020-04-13       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.