Literature DB >> 31312808

Continuous Blood Pressure Monitoring using Wrist-worn Bio-impedance Sensors with Wet Electrodes.

Bassem Ibrahim1, Roozbeh Jafari2,3,1.   

Abstract

Continuous blood pressure (BP) monitoring is essential for diagnosis and management of cardiovascular disorders. Currently, BP is measured using cuff-based methods, which are obtrusive and not suitable for continuous monitoring. Estimation of BP using pulse transit time (PTT) is a prominent method that eliminates the need for a cuff. In this paper, we present a new method to estimate BP based on PTT measurements from an array of 2×2 bio-impedance sensors placed on the wrist, which can be integrated into a small wearable device such as a smart watch for continuous BP monitoring. Diastolic and systolic BP were estimated using AdaBoost regression model based on PTT features extracted from the wrist bio-impedance signals. Data was collected from three participants using our custom bio-impedance sensors. Our method can estimate BP accurately with correlation coefficient, mean absolute error (MAE) and standard deviation (STD) of 0.92, 1.71 and 2.46 mmHg for the diastolic BP and 0.94, 2.57 and 4.35 mmHg for the systolic BP.

Entities:  

Keywords:  Continuous Blood pressure monitoring; cuffless; regression model; wrist bio-impedance sensors

Year:  2018        PMID: 31312808      PMCID: PMC6631025          DOI: 10.1109/BIOCAS.2018.8584783

Source DB:  PubMed          Journal:  IEEE Biomed Circuits Syst Conf


  4 in total

1.  Cuffless Blood Pressure Monitoring from an Array of Wrist Bio-Impedance Sensors Using Subject-Specific Regression Models: Proof of Concept.

Authors:  Bassem Ibrahim; Roozbeh Jafari
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2019-10-10       Impact factor: 3.833

2.  Non-Invasive Cardiac and Respiratory Activity Assessment From Various Human Body Locations Using Bioimpedance.

Authors:  Kaan Sel; Deen Osman; Roozbeh Jafari
Journal:  IEEE Open J Eng Med Biol       Date:  2021-06-01

3.  Cuffless blood pressure monitoring from a wristband with calibration-free algorithms for sensing location based on bio-impedance sensor array and autoencoder.

Authors:  Bassem Ibrahim; Roozbeh Jafari
Journal:  Sci Rep       Date:  2022-01-10       Impact factor: 4.379

4.  Management of Hypertension in the Digital Era: Small Wearable Monitoring Devices for Remote Blood Pressure Monitoring.

Authors:  Kazuomi Kario
Journal:  Hypertension       Date:  2020-08-03       Impact factor: 10.190

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.