Abstract
Short repetitive regions in autosomal and Y chromosomes known as short tandem repeats (STRs) are currently used for DNA profiling in crime investigations. However, DNA profiling requires a sufficient quality and quantity of DNA template, which is often not obtained from trace evidence or degraded biological samples collected at the scene of a crime. Here, we assessed autosomal and male DNA components extracted from crime scene and mock casework samples using the Casework Direct Kit, Custom and compared the results against those obtained by extraction of matching samples using well-established Maxwell 16 System DNA IQ Casework Pro Kit. The quantity and quality of extracted DNA obtained using both Casework Direct Kit, Custom and Maxwell 16 System DNA IQ Casework Pro Kit were analyzed using PowerQuant Systems followed by autosomal and Y-chromosome STR profiling using GlobalFiler Express PCR Amplification Kit and PowerPlex Y23 System, respectively. Our results showed that the Casework Direct Kit and Maxwell 16 DNA IQ Casework Pro Kit have more or less equal capacity to extract inhibitor free DNA, but that the latter produces slightly better quality and more DNA template and subsequently higher numbers of STR allele calls for autosomal and Y-STR analyses. Nonetheless, the Casework Direct Kit, Custom is the quicker and cheaper option for extraction of good, clean DNA from high content material and might best be used for extraction of reference samples. Such reference DNA samples typically come from buccal swabs or freshly drawn blood. So, in general, they can confidently be expected to have a high nucleic acid content and to be inhibitor-free.Entities:
Mesh:
Substances:
Year: 2019 PMID: 31601905 PMCID: PMC6787247 DOI: 10.1038/s41598-019-51154-4
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Quality and quantity of DNA extracted using Casework Direct Kit and Maxwell 16 System Forensic Kit and amount used for autosomal and Y chromosome STR profiling.
| Sample ID | qPCR result (ng/µL) | Total Yield (ng) | [Auto]/[D] | [Auto]/[Y] | IPC | DNA input for STR (pg) | Autosomal allele call (%) | Male DNA allele call (%) | |||
|---|---|---|---|---|---|---|---|---|---|---|---|
| [Auto] | [Y] | Auto DNA | Y DNA | Auto STR | Y-STR | ||||||
| CD 1/CS 1 | 0.0002/0.0018 | No Cq/No Cq | 0.08/0.09 | NA/NA | U/1.6 | U/NA | −0.44/−0.29 | 0.5/5.4 | 0.0/0.0 | 45.8/83.3 | 0.0/4.5 |
| CD 2/CS 2 | NA/0.0007 | No Cq/0.0005 | NA/0.035 | NA/0.025 | NA/U | NA/1.34 | −0.29/−0.47 | 0.0/2.2 | 0.0/4.1 | 70.8/25.0 | 0.0/27.3 |
| CD 3/CS 3 | 0.0051/0.0645 | No Cq/No Cq | 1.53/3.225 | NA/NA | 3.18/3.33 | NA/U | −0.53/−0.30 | 15.4/193.5 | 0.0/0.0 | 66.7/91.7 | 4.5/13.6 |
| CD 4/CS 4 | NA/0.0006 | No Cq/No Cq | NA/0.03 | NA/NA | NA/U | NA/U | −0.51/−0.46 | 0.0/1.7 | 0.0/0.0 | 25.0/45.8 | 0.0/22.7 |
| CD 5/CS 5 | 0.0005/0.0015 | No Cq/0.0018 | 0.2/0.075 | U/0.09 | 1.72/1.8 | U/0.85 | −0.42/−0.18 | 1.6/4.6 | 0.0/13.6 | 50.0/70.8 | 22.7/40.9 |
| CD 6/CS 6 | 0.1109/0.1018 | 0.0864/0.0746 | 33.27/5.09 | 25.92/3.73 | 2.38/2.93 | 1.28/1.37 | −0.16/−0.15 | 332.8/305.5 | 500.0/500.0 | 100/100 | 68.2/100 |
| CD 7/CS 7 | 0.0344/0.0806 | 0.035/0.0652 | 10.32/4.03 | 10.5/3.26 | 1.84/2.81 | 0.98/1.24 | −0.47/−0.01 | 103.2/241.9 | 262.5/488.7 | 100/100 | 72.7/100 |
| CD 8/CS 8 | 0.0181/0.5395 | 0.0162/0.5063 | 5.43/26.975 | 4.86/25.315 | 3.2/1.85 | 1.12/1.07 | −0.05/−0.14 | 54.2/1618.6 | 121.3/500.0 | 8.3/100 | 13.6/100 |
| CD 9/CS 9 | 0.0645/0.2869 | 0.0289/0.2138 | 19.35/14.345 | 8.67/10.69 | 2.54/2.4 | 2.23/1.34 | −0.4/−0.35 | 193.6/860.8 | 216.7/500.0 | 95.8/100 | 86.4/100 |
| CD 10/CS 10 | 0.0739/0.0634 | 0.0702/0.0597 | 29.56/3.17 | 28.08/2.985 | 1.38/2.14 | 1.05/1.06 | −0.23/−0.12 | 221.6/190.2 | 500.0/447.4 | 100/100 | 59.1/100 |
| CD 11/CS 11 | 0.0074/0.0546 | 0.0053/0.053 | 2.96/2.73 | 2.12/2.65 | 2.35/2.21 | 1.4/1.03 | −0.54/−0.30 | 22.3/163.9 | 39.9/397.8 | 95.8/100 | 54.5/100 |
| CD 12/CS 12 | 19.2819/18.902 | No Cq/No Cq | 7712.76/945.1 | NA/NA | 1.45/1.31 | U/U | 0.03/−0.04 | 500.0/540.0 | 0.0/0.0 | 100/100 | 0.0/0.0 |
| Average allele call (%) | 78.0/92.4 | 34.7/64.5 | |||||||||
[Auto] – qPCR concentration results of autosomal DNA, [Y] – qPCR concentration results of male DNA, [Auto]/[D] – autosomal STR degradation, [Auto]/[Y] - mixture of female and male DNA, IPC - internal positive control, U – undetermined and No Cq – no cycle quantification value. Values for the two blank swab samples were not included as no DNA and STR allele were observed.
Figure 1Amount of genomic extracted using Casework Direct Kit, Custom and Maxwell 16 System DNA IQ Casework Pro Kit. We obtained high DNA concentration (7712.76 ng/ul and 945.1 ng/ul for Casework Direct Kit, Custom and Maxwell 16 System DNA IQ Casework Pro Kit, respectively) for the female reference samples (i.e. CD12/CS 12). Data for these reference samples were not shown in the graph as it will distort value for other data points.
Figure 2Amount of male DNA extracted using Casework Direct Kit, Custom and Maxwell 16 System DNA IQ Casework Pro Kit.
Figure 3Percentages of autosomal STR allele calls for DNA extracted using Casework Direct, Custom Kit and Maxwell16 System DNA IQ Casework Pro Kit.
Figure 4Percentages of Y chromosome STR allele calls for male DNA extracted using Casework Direct, Custom Kit and Maxwell 16 System DNA IQ Casework Pro kit.
Figure 5Autosomal DNA profiles developed from the swab of knife’s handle (CD 5 and CS 5) and cuttings from the cigarette butt (CD 6 and CS 6). CD 5 and CD 6 represent the profile from the sample extracted using Casework Direct Kit, Custom. CS 5 and CS 6 represents the profile from the sample extracted using the Maxwell 16 Instrument with the DNA IQ Casework Pro Kit. Samples were quantified using the PowerQuant System on the Applied Biosystems 7500 Real-Time PCR System. Amplification was performed using the Globalfiler Express on a GeneAmp 9700. One microliter of amplified product was electrophoresed on an Applied Biosystems 3500xL instrument using a 1.2 kv, 24-second injection.
Figure 6Male DNA profiles developed from the swab of knife’s handle (CD 3 and CS 3) and cuttings from the cigarette butt (CD 6 and CS 6). CD 3 and CD 6 represent the profile from the sample extracted using Casework Direct Kit, Custom. CS 3 and CS 6 represents the profile from the sample extracted using the Maxwell 16 Instrument with the DNA IQ Casework Pro Kit. Samples were quantified using the PowerQuant System on the Applied Biosystems 7500 Real-Time PCR System. Amplification was performed using the PowerPlex Y23 System on a GeneAmp 9700. One microliter of amplified product was electrophoresed on an Applied Biosystems 3500xL instrument using a 1.2 kv, 24-second injection.
List of 12 samples used in this assessment study that consist of 8 casework samples, 3 mock samples (prepared in-house via swabbing procedure) and 1 buccal swab sample from a female donor.
| DNA source | Sample type | Sample category | Sample ID | |
|---|---|---|---|---|
| Casework Direct Kit | Maxwell 16 System DNA | |||
| Knife | Swab | Casework | CD 1 | CS 1 |
| Hair without follicle | Cutting | Casework | CD 2 | CS 2 |
| Plastic straw | Cutting | Casework | CD 3 | CS 3 |
| Blood on floor | Swab | Casework | CD 4 | CS 4 |
| Door knob | Swab | Mock casework | CD 5 | CS 5 |
| Cigarette butt 1 | Cutting | Casework | CD 6 | CS 6 |
| Cigarette butt 2 | Cutting | Casework | CD 7 | CS 7 |
| Tissue clot | Cutting | Casework | CD 8 | CS 8 |
| Latex glove | Cutting | Casework | CD 9 | CS 9 |
| Computer mouse | Swab | Mock casework | CD 10 | CS 10 |
| Watch | Swab | Mock casework | CD 11 | CS 11 |
| Female buccal cell | Swab | Negative control for male DNA | CD 12 | CS 12 |