The Qiagen Investigator® Quantiplex HYres as an alternative kit for DNA quantification.

Chantal J Frégeau1, Nancy Laurin2.   

Abstract

The Investigator® Quantiplex HYres kit was evaluated as a potential replacement for dual DNA quantification of casework samples. This kit was determined to be highly sensitive with a limit of quantification and limit of detection of 0.0049ng/μL and 0.0003ng/μL, respectively, for both human and male DNA, using full or half reaction volumes. It was also accurate in assessing the amount of male DNA present in 96 mock and actual casework male:female mixtures (various ratios) processed in this exercise. The close correlation between the male/human DNA ratios expressed in percentages derived from the Investigator® Quantiplex HYres quantification results and the male DNA proportion calculated in mixed AmpFlSTR® Profiler® Plus or AmpFlSTR® Identifiler® Plus profiles, using the Amelogenin Y peak and STR loci, allowed guidelines to be developed to facilitate decisions regarding when to submit samples to Y-STR rather than autosomal STR profiling. The internal control (IC) target was shown to be more sensitive to inhibitors compared to the human and male DNA targets included in the Investigator® Quantiplex HYres kit serving as a good quality assessor of DNA extracts. The new kit met our criteria of enhanced sensitivity, accuracy, consistency, reliability and robustness for casework DNA quantification. Crown
Copyright © 2015. Published by Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Casework; DNA mixtures; Dual DNA quantification; Forensic science; Inhibition studies; Scorpion primer probe; “Direct to DNA” approach for sexual assault cases

Mesh:

Substances:

Year:  2014        PMID: 25603128     DOI: 10.1016/j.fsigen.2014.12.010

Source DB:  PubMed          Journal:  Forensic Sci Int Genet        ISSN: 1872-4973            Impact factor:   4.882


  2 in total

1.  Assessment of autosomal and male DNA extracted from casework samples using Casework Direct Kit, Custom and Maxwell 16 System DNA IQ Casework Pro Kit for autosomal-STR and Y-STR profiling.

Authors:  Hashom Mohd Hakim; Hussein Omar Khan; Siti Afifah Ismail; Shahrizad Ayob; Japareng Lalung; Edward Abban Kofi; Geoffrey Keith Chambers; Hisham Atan Edinur
Journal:  Sci Rep       Date:  2019-10-10       Impact factor: 4.379

2.  Improved resolution of mixed STR profiles using a fully automated differential cell lysis/DNA extraction method.

Authors:  Matthew C Goldstein; Jordan O Cox; Lori B Seman; Tracey Dawson Cruz
Journal:  Forensic Sci Res       Date:  2019-08-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.