Literature DB >> 31596335

Reinforced Glass-ceramics: Parametric Inspection of Three-Dimensional Wear and Volumetric Loss after Chewing Simulation.

João Paulo Mendes Tribst1,2, Larissa Marcia Marques Alves1, Amanda Maria de Oliveira Dal Piva1,2, Renata Marques de Melo1, Alexandre Luiz Souto Borges1, Tarcísio José Arruda Paes-Junior1, Marco Antonio Bottino1.   

Abstract

The aim of this study was to investigate the three-dimensional wear, volumetric loss and surface roughness after chewing simulation of two glass ceramics. Lithium disilicate (LD, Emax CAD, Ivoclar) and Zirconia reinforced lithium silicate (ZLS, Vita Suprinity, Vita Zhanfabrick) discs (n=20/g) were scanned to obtain stereolithography (STL) files for each sample. All discs were submitted to chewing simulation with sliding configuration (30 N, 300,000 cycles, 6 mm and 1.7 Hz) with steatite as antagonist. The samples were then scanned again and the volume loss and the deepest defect depth was measured using the superimposed file from the baseline using three-dimensional digital parametric inspection software (GOM Inspect, Braunschweig, Germany). Surface roughness (Ra and Rz) was analyzed with a contact profilometer. Data were analyzed by one-way ANOVA and Tukey test (α=0.5%). ANOVA showed significant differences among the groups. Considering the ceramic volume loss, wear depth defect length and Rz roughness, LD (-22.09±5.57%; 0.80±0.06 µm; 3.08±1.02 µm) showed higher mean values than ZLS (-15.67±4.51%; 0.56±0.09 µm; 1.51±0.90 µm). Ra mean values were similar for both materials (p=0.064). All discs exhibited slight surface scratches along with the sliding direction with pitted wear patterns, while large cracks were observed on wear traces. These same areas can be identified in blue, overlapping the STL files before and after chewing simulation in inspection software. The linear reduction generated by sliding contact shows a graph with a similar wear pattern shape. ZLS was more resistant to wear than LD, with less volume loss and shallower surface defects.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31596335     DOI: 10.1590/0103-6440201902699

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  3 in total

1.  The flexural strength of CAD/CAM polymer crowns and the effect of artificial ageing on the fracture resistance of CAD/CAM polymer and ceramic single crowns.

Authors:  Anna Winter; Axel Schurig; Engelke Rasche; Franziska Rösner; Lisa Kanus; Marc Schmitter
Journal:  J Mater Sci Mater Med       Date:  2019-12-23       Impact factor: 3.896

2.  Effect of framework type on survival probability of implant-supported temporary crowns: An in vitro study.

Authors:  Vinícius-Anéas Rodrigues; Amanda-Maria-de Oliveira Dal Piva; Claudio-Akira Yamaguchi; Alexandre-Luiz-Souto Borges; Marcio-Katsuyoshi Mukai; João-Paulo-Mendes Tribst
Journal:  J Clin Exp Dent       Date:  2020-05-01

3.  Clinical efficacy of ceramic versus resin-based composite endocrowns in Chinese adults: study protocol for a randomized controlled trial.

Authors:  Jilei Wang; Zhiting Ling; Ziting Zheng; Chunqing Zheng; Yawen Gai; Yuting Zeng; Xiaoxia Zhu; Liya Chen; Buling Wu; Wenjuan Yan
Journal:  Trials       Date:  2020-06-22       Impact factor: 2.279

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.