Triton sponge and canister app for estimating surgical blood loss.

Abhijit S Nair1, Vibhavari Naik1, Narahari Busa1, Basanth K Rayani1.   

Abstract

Entities:  

Year:  2019        PMID: 31572095      PMCID: PMC6753745          DOI: 10.4103/sja.SJA_38_19

Source DB:  PubMed          Journal:  Saudi J Anaesth


× No keyword cloud information.
Sir, Conventionally gravimetric method and visual estimations are used to quantify intraoperative blood loss. In gravimetric method, soaked mops are weighed and difference in grams is estimated as blood loss in ml. In visual estimation, loss is estimated by the amount seen in drains and mops after which a rough quantification is done after enquiring about the saline wash used intraoperatively or the body fluids which is drained. Both methods are inconsistent in determining surgical blood loss. The loss is underestimated in major surgeries which involves excessive blood loss and overestimated in otherwise minimal blood loss. The Triton system (Gauss Surgical, Inc., Palo Alto, CA) is a mobile monitoring system that uses mobile computing with Gauss “'Feature Extraction Technology” (FET). The application can be downloaded on an iPad from the App Store on Macintosh platform by searching “Triton Sponge” [Figure 1a]. The application helps by directly assessing Hb mass (mHb) absorbed by surgical sponges from an image. The software works using algorithms, which can automatically filter out nonsanguineous components such as saline used for wash, body fluids like ascites, urine, pleural fluid that is absorbed by the mops. Triton system got US-FDA approval as an “'Image Processing Device For Estimation Of External Blood Loss' with an 510(K) number: K163507.
Figure 1

(a) Figure shows Triton Sponge App as available on App Store. (b) Figure shows Triton Canister App as available on App Store

(a) Figure shows Triton Sponge App as available on App Store. (b) Figure shows Triton Canister App as available on App Store Later, Gauss Surgical, Inc. launched 'Triton Canister' app, which used FET to estimate blood loss in canisters and other suction containers used to collect intraoperative losses [Figure 1b]. The app can be found on App store by typing “Triton Canister v2”. In this app also the image of suction containers and canisters needs to be uploaded, which is then processed and an accurate estimate of blood loss is then provided by the app after excluding other fluids in the canisters. The canister app also received US-FDA approval in 2015 under device classification “Image Processing Device For Estimation Of External Blood Loss” with 510(K) Number: K142801.(8) After the FDA approval, several studies have been conducted involving major laparotomies, orthopedic surgeries (spine, arthroplasties), cesarean deliveries[12345] [Table 1]. Konig et al. conducted an in vitro study to assess the accuracy and performance of the app on surgical laparotomy sponges and later on suction canisters across various range of ambient light conditions, sponge saturation, saline contamination, and initial blood Hb and found it very accurate.[6] Although the sample size of the studies published till date is small, respective authors felt that this algorithm based app was much better and reliable in estimating intraoperative blood loss, thereby helping the clinicians to take decisions judiciously.
Table 1

Table shows currently published papers which used the Triton Sponge and Canister App for estimation of intra-operative blood loss

AuthorsApp usedNo. of patientsConclusion
Holmes et al. (2014)Sponge46App provided significantly more accurate estimation of Hb mass than the gravimetric method.
Sharareh et al. (2015)Sponge50App could accurately determine Hb loss contained within surgical sponges.
Doctorvaladan et al. (2017)Sponge and canister50App based algorithmic system provides more accurate results than visual and quantitative gravimetric methods of measuring blood loss during cesarean deliveries.
Konig et al. (2017)Sponge50Use of the Triton App to measure Hb loss in real-time during surgery was feasible and accurate.
Nowicki et al. (2018)Sponge56Authors concluded that intraoperative use of the Triton system was convenient and precise for monitoring intraoperative blood loss when compared to gravimetric method and visual estimation.
Table shows currently published papers which used the Triton Sponge and Canister App for estimation of intra-operative blood loss To conclude, the Triton system-based estimation of intraoperative blood loss in sponges and canisters is a simple and reasonably accurate way of estimating blood loss. It is easy to learn and understand. Presently, the app is available for free download on Macintosh platform only although the user's needs to purchase the license to use the app. The app can be used on an iPad once installed with a functional internet connection. Being a regulated medical product, the app is available for use in a country if the product is cleared by local regulating bodies.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  6 in total

1.  In Vitro Evaluation of a Novel Image Processing Device to Estimate Surgical Blood Loss in Suction Canisters.

Authors:  Gerhardt Konig; Jonathan H Waters; Eric Hsieh; Bridget Philip; Vicki Ting; Gaurav Abbi; Mazyar Javidroozi; Griffeth W Tully; Gregg Adams
Journal:  Anesth Analg       Date:  2018-02       Impact factor: 5.108

2.  Clinical evaluation of a novel system for monitoring surgical hemoglobin loss.

Authors:  Allen A Holmes; Gerhardt Konig; Vicki Ting; Bridget Philip; Thomas Puzio; Siddarth Satish; Jonathan H Waters
Journal:  Anesth Analg       Date:  2014-09       Impact factor: 5.108

3.  Real-time evaluation of an image analysis system for monitoring surgical hemoglobin loss.

Authors:  Gerhardt Konig; Jonathan H Waters; Mazyar Javidroozi; Bridget Philip; Vicki Ting; Gaurav Abbi; Eric Hsieh; Griffeth Tully; Gregg Adams
Journal:  J Clin Monit Comput       Date:  2017-04-07       Impact factor: 2.502

4.  Real Time Intraoperative Monitoring of Blood Loss with a Novel Tablet Application.

Authors:  Behnam Sharareh; Spencer Woolwine; Siddarth Satish; Peter Abraham; Ran Schwarzkopf
Journal:  Open Orthop J       Date:  2015-08-31

5.  Accuracy of Blood Loss Measurement during Cesarean Delivery.

Authors:  Sahar V Doctorvaladan; Andrea T Jelks; Eric W Hsieh; Robert L Thurer; Mark I Zakowski; David C Lagrew
Journal:  AJP Rep       Date:  2017-04

6.  Measurement of Intraoperative Blood Loss in Pediatric Orthopaedic Patients: Evaluation of a New Method.

Authors:  Philip D Nowicki; Akunne Ndika; John Kemppainen; Jeffrey Cassidy; Michael Forness; Siddarth Satish; Nabil Hassan
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2018-05-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.