Literature DB >> 31515047

Endodontic Microsurgery Using Dynamic Navigation System: A Case Report.

Gianluca Gambarini1, Massimo Galli1, Luigi V Stefanelli1, Dario Di Nardo2, Antonio Morese1, Marco Seracchiani1, Francesca De Angelis1, Stefano Di Carlo1, Luca Testarelli1.   

Abstract

Dynamic navigation systems were introduced to facilitate dental implantology by improving the accuracy of dental implant positioning. Dynamic navigation integrates surgical instrumentation and radiologic images by using an optical positioning device controlled by a dedicated computerized interface. These features could help in reducing the risk of unintentional iatrogenic damage to nearby anatomic structures and perform minimally invasive or flapless surgery, leading to reduced patient postoperative discomfort and improved healing. The present case report showed the use of the Navident dynamic navigation system (ClaroNav, Toronto, Ontario, Canada) by an undergraduate student for bone cavity preparation and root-end resection in the surgical endodontic treatment of a lesion in an upper lateral incisor. The system allowed precise localization of the root and precise apicoectomy with a minimal invasive cavity. The dynamic navigation system allowed the student to precisely direct the bur in 3 dimensions. The osteotomy and root-end resection were easily and quickly performed by the undergraduate student with a minimally invasive approach without iatrogenic errors. The navigation system allowed the operator to precisely perform a minimally invasive osteoctomy and root-end resection during endodontic surgery. The development of dedicated surgical navigation systems for endodontic surgery could facilitate the operator's maneuvers and reduce the risk of iatrogenic errors.
Copyright © 2019 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Apicoectomy; Navident; dynamic navigation surgery; microsurgery

Mesh:

Substances:

Year:  2019        PMID: 31515047     DOI: 10.1016/j.joen.2019.07.010

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  9 in total

1.  [In vitro evaluation of positioning accuracy of trephine bur at different depths by dynamic navigation].

Authors:  S M Liu; Y J Zhao; X Y Wang; Z H Wang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2022-02-18

Review 2.  Static vs. dynamic navigation for endodontic microsurgery - A comparative review.

Authors:  Geo T D; Payal Saxena; Saurabh Gupta
Journal:  J Oral Biol Craniofac Res       Date:  2022-05-17

3.  Dynamic Navigation in Guided Endodontics - A Systematic Review.

Authors:  Aishwarya Vasudevan; Sneha Susan Santosh; Rene Jochebed Selvakumar; Durga Tharini Sampath; Velmurugan Natanasabapathy
Journal:  Eur Endod J       Date:  2022-06

Review 4.  Accuracy of Dynamic Navigation for Non-Surgical Endodontic Treatment: A Systematic Review.

Authors:  Egle Marija Jonaityte; Goda Bilvinaite; Saulius Drukteinis; Andres Torres
Journal:  J Clin Med       Date:  2022-06-15       Impact factor: 4.964

5.  Dynamic navigation optimizes endodontic microsurgery in an anatomically challenging area.

Authors:  Yi-Jung Lu; Liang-Han Chiu; Liang-Yi Tsai; Chih-Yuan Fang
Journal:  J Dent Sci       Date:  2021-07-20       Impact factor: 2.080

6.  Innovations in Diagnostic Imaging in Oral and Maxillofacial Diseases.

Authors:  Maurilio D'Angelo; Alessio Zanza; Dario Di Nardo; Luca Testarelli
Journal:  Diagnostics (Basel)       Date:  2022-02-19

7.  Combined Application of Virtual Simulation Technology and 3-Dimensional-Printed Computer-Aided Rapid Prototyping in Autotransplantation of a Mature Third Molar.

Authors:  Hui Zhang; Min Cai; Zhiguo Liu; He Liu; Ya Shen; Xiangya Huang
Journal:  Medicina (Kaunas)       Date:  2022-07-19       Impact factor: 2.948

8.  Accuracy of Endodontic Access Cavities Performed Using an Augmented Reality Appliance: An In Vitro Study.

Authors:  Vicente Faus-Matoses; Vicente Faus-Llácer; Tanaz Moradian; Elena Riad Deglow; Celia Ruiz-Sánchez; Nirmine Hamoud-Kharrat; Álvaro Zubizarreta-Macho; Ignacio Faus-Matoses
Journal:  Int J Environ Res Public Health       Date:  2022-09-06       Impact factor: 4.614

9.  Accuracy of Computer-Aided Dynamic Navigation Compared to Computer-Aided Static Procedure for Endodontic Access Cavities: An in Vitro Study.

Authors:  Álvaro Zubizarreta-Macho; Ana de Pedro Muñoz; Elena Riad Deglow; Rubén Agustín-Panadero; Jesús Mena Álvarez
Journal:  J Clin Med       Date:  2020-01-02       Impact factor: 4.241

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.