Literature DB >> 31514860

A biosensor for determination of the circulating biomarker CA125/MUC16 by Surface Plasmon Resonance Imaging.

B Szymańska1, Z Lukaszewski2, K Hermanowicz-Szamatowicz3, E Gorodkiewicz4.   

Abstract

CA125/MUC16 is an ovarian tumor cell marker widely used as a biomarker in epithelial ovarian carcinoma. CA125/MUC16 is also used for evaluation of the ROMA (Risk of Ovarian Malignancy Algorithm) value. In this work, a Surface Plasmon Resonance Imaging (SPRI) biosensor for circulating CA125/MUC16 has been developed. The anti-MUC16 antibody was attached to a gold chip via a cysteamine linker. The EDS/NHS protocol was used for the covalent attachment of the antibody. The developed biosensor is specific for CA125/MUC16, and exhibits good recovery and acceptable precision. Its linear response range (2.2-150 U/ml) is well suited to determination of the marker in the blood serum of a healthy control group and, after appropriate dilution, of patients with ovarian cancer. CA125/MUC16 was determined in two series of real samples: blood serum from patients with ovarian cancer and endometrial cysts. The method was validated by parallel determination of the samples using the chemiluminescent Architect i2000 method.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Architect i2000; CA125; Endometrial cysts; MUC 16; Ovarian cancer; SPRI

Mesh:

Substances:

Year:  2019        PMID: 31514860     DOI: 10.1016/j.talanta.2019.120187

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

1.  Two Biosensors for the Determination of Interleukin-6 in Blood Plasma by Array SPRi.

Authors:  Beata Szymanska; Zenon Lukaszewski; Lukasz Oldak; Beata Zelazowska-Rutkowska; Kinga Hermanowicz-Szamatowicz; Ewa Gorodkiewicz
Journal:  Biosensors (Basel)       Date:  2022-06-14

2.  An SPRi Biosensor for Determination of the Ovarian Cancer Marker HE4 in Human Plasma.

Authors:  Beata Szymanska; Zenon Lukaszewski; Beata Zelazowska-Rutkowska; Kinga Hermanowicz-Szamatowicz; Ewa Gorodkiewicz
Journal:  Sensors (Basel)       Date:  2021-05-20       Impact factor: 3.576

Review 3.  Recent Advancements in Receptor Layer Engineering for Applications in SPR-Based Immunodiagnostics.

Authors:  Marcin Drozd; Sylwia Karoń; Elżbieta Malinowska
Journal:  Sensors (Basel)       Date:  2021-05-29       Impact factor: 3.576

Review 4.  Low-Fouling Substrates for Plasmonic Sensing of Circulating Biomarkers in Biological Fluids.

Authors:  Elba Mauriz
Journal:  Biosensors (Basel)       Date:  2020-06-10

Review 5.  Recent Progress in Optical Sensors for Biomedical Diagnostics.

Authors:  Muqsit Pirzada; Zeynep Altintas
Journal:  Micromachines (Basel)       Date:  2020-03-30       Impact factor: 2.891

6.  A Comparison of Various Chips Used for the Manufacture of Biosensors Applied in Non-Fluidic Array SPRi, Based on the Example of Determination of Cathepsin D.

Authors:  Pawel Falkowski; Piotr Mrozek; Piotr Miluski; Zenon Lukaszewski; Ewa Gorodkiewicz
Journal:  Biosensors (Basel)       Date:  2021-12-31
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.