| Literature DB >> 31511006 |
Xiang-Fei Feng1, Ling-Chao Yang2, Li-Zhuang Tan3, Yi-Gang Li4.
Abstract
BACKGROUND: The incidence of cardiac implantable electronic device infection (CIEDI) is low and usually belongs to the typical imbalanced dataset. We sought to describe our experience on the management of the imbalanced CIEDI dataset.Entities:
Keywords: Device; Implantation; Infection; Re-sampling technique; Risk factors
Mesh:
Year: 2019 PMID: 31511006 PMCID: PMC6737640 DOI: 10.1186/s12911-019-0899-4
Source DB: PubMed Journal: BMC Med Inform Decis Mak ISSN: 1472-6947 Impact factor: 2.796
Fig. 1Study design and flow chart
Clinical characteristics of device patients with infection or Un-infection group (n = 4959)
| Infection group ( | Un-infection group ( | ||
|---|---|---|---|
| Male, N (%) | 22 (78.6%) | 2606 (52.8%) | 0.007 |
| Female, N (%) | 6 (21.4%) | 2325 (47.2%) | 0.007 |
| Age (yrs), mean ± SD | 65.5 ± 12.2 | 71.3 ± 14.2 | 0.178 |
| Diabetes, n (%) | 5 (17.9%) | 951 (19.3%) | 0.848 |
| Pre-operation antibiotics, n (%) | 26 (92.9%) | 4754 (96.4%) | 0.619 |
| Post-operation antibiotics, n (%) | 26 (92.9%) | 4754 (96.4%) | 0.619 |
| Replacement procedure, n(%) | 15 (53.6%) | 1136 (23.0%) | 0.001 |
| Post-operation fever, n(%) | 4 (14.3%) | 414 (8.4%) | 0.437 |
| ICD, n(%) | 2 (7.1%) | 644 (13.1%) | 0.518 |
ICD implantable cardioverter defibrillator
Dichotomized device infection patients across clinical variables (n=28)
| Clinical variables (Group I & Group II ) | Group I | Group II | |
|---|---|---|---|
| n (total,%) | n (total,%) | ||
| Gender (male & female) | 22 (2628,0.8) | 6 (2331, 0.3) | 0.007 |
| Post-operation fever (yes & no) | 4 (418,1.0) | 24 (4541,0.5) | 0.437 |
| Antibiotics (yes & no) | 26 (4819,0.5) | 2 (140,1.4) | 0.417 |
| Device type (pacemaker & ICD) | 26 (4313,0.6) | 2 (646,0.3) | 0.518 |
| Type of procedure (primary & replacement) | 13 (3705,0.4) | 15 (1254,1.2) | 0.001 |
ICD Implantable cardioverter defibrillator
Multivariable logistic regression analysis before re-sampling (n = 4959)
| Variables | Β | SE | OR | 95%CI | |
|---|---|---|---|---|---|
| Age | 0.031 | 0.011 | 1.032 | 1.010–1.054 | 0.004 |
| gender | 1.254 | 0.365 | 3.503 | 1.712–7.169 | 0.001 |
| replacement procedure | −2.735 | 0.361 | 0.065 | 0.032--0.132 | 0.000 |
| antibiotics | −1.386 | 0.632 | 0.250 | 0.72–0.863 | 0.028 |
CI confidence intervals, SE standard error
Fig. 2Comparison in ROC curves and AUCs between before (left) and after (right) re-sampling in prediction of CIEDI with similar variables. As shown in Figure, whether before or after re-sampling, replacement procedure, gender, and age all had large AUC. This suggests potential roles of them in prediction of patients at risks for CIEDI
Clinical characteristics of device patients after re-sampling (n = 739)
| Infection group ( | Un-infection group ( | ||
|---|---|---|---|
| Male, N (%) | 96 (78.0%) | 303 (49.2%) | 0.001 |
| Female, N (%) | 27 (22.0%) | 313 (50.8%) | 0.001 |
| Age (yrs), mean ± SD | 67.3 ± 11.4 | 73.9 ± 11.3 | 0.001 |
| Diabetes, n (%) | 18 (16.7%) | 90 (19.3%) | 0.995 |
| Pre-operation antibiotics, n (%) | 115 (93.5%) | 616 (100%) | 0.001 |
| Post-operation antibiotics, n (%) | 115 (93.5%) | 616 (100%) | 0.001 |
| Replacement procedure, n(%) | 52 (42.3%) | 450 (73.1%) | 0.001 |
| Post-operation fever, n(%) | 18 (14.6%) | 41 (6.7%) | 0.003 |
| ICD, n(%) | 8 (6.5%) | 20 (3.2%) | 0.142 |
ICD implantable cardioverter defibrillator
Multivariable logistic regression analysis after re-sampling (n = 739)
| Variables | Β | SE | OR | 95%CI | |
|---|---|---|---|---|---|
| Age | 0.040 | 0.013 | 1.041 | 1.015–1.067 | 0.002 |
| gender | 1.429 | 0.475 | 4.176 | 1.647–10.590 | 0.003 |
| replacement procedure | −2.498 | 0.394 | 0.082 | 0.038–0.178 | 0.000 |
| antibiotics | −23.263 | 13,197 | 0.000 | 0.000–0.000 | 0.999 |
CI confidence intervals, SE standard error