Literature DB >> 31489862

Evaluation of the use of PEEK material in implant-supported fixed restorations by finite element analysis.

S Tekin1, Y Değer2, F Demirci3.   

Abstract

AIMS: The purpose of this study is to compare the stresses occurring in the peri-implant bones, implants, crowns, abutments, and screws after loading through finite element analysis by using the poly-ether-ether-ketone (PEEK) materials, which are alternative to titanium abutment and metal supported restorations and to try to reduce the level of neck resorption.
MATERIALS AND METHODS: In our study, three-dimensional modeling of 2 PEEK and titanium abutments, metal-ceramic, and monolithic PEEK upper central dental restorations were made on four titanium implants (Biohorizons® Implant Systems Ins., Birmingham, AL, USA) with diameters of 3.8 mm and 10.5 mm and four groups were obtained. Then, a stress analysis of the finite element was performed by applying a 178 N oblique force of 45° to the long axis of the tooth 2 mm below the incisal edge of the model's palatal surface.
RESULTS: It has been observed that the PEEK material reduces the stresses caused by the force applied on itself during all tests. In all groups, PEEK abutments and PEEK crowns have reduced stress on the abutment. The most significant difference is observed in the stresses on the crowns and screws. When the stresses on the crown are examined, the use of PEEK crown reduces the stresses on itself and the use of PEEK abutment increases the stresses on the crown.
CONCLUSIONS: The stress on the implant system can be changed through the usage of different prosthetic materials.

Entities:  

Keywords:  Dental implant; finite element analysis; poly-ether-ether-ketone

Mesh:

Substances:

Year:  2019        PMID: 31489862     DOI: 10.4103/njcp.njcp_144_19

Source DB:  PubMed          Journal:  Niger J Clin Pract            Impact factor:   0.968


  5 in total

1.  Finite Element Analysis of effect of cusp inclination and occlusal contacts in PFM and PEEK implant-supported crowns on resultant stresses.

Authors:  Githanjali Manchikalapudi; Sreeramulu Basapogu
Journal:  Med J Armed Forces India       Date:  2021-01-16

2.  Stress distribution around different abutments on titanium and CFR-PEEK implant with different prosthetic crowns under parafunctional loading: A 3D FEA study.

Authors:  Akanksha Mourya; Rajvi Nahar; Sunil Kumar Mishra; Ramesh Chowdhary
Journal:  J Oral Biol Craniofac Res       Date:  2021-03-16

Review 3.  Behavior of polyether-ether-ketone (PEEK) in prostheses on dental implants. A review.

Authors:  Natalia Blanch-Martínez; Santiago Arias-Herrera; Amparo Martínez-González
Journal:  J Clin Exp Dent       Date:  2021-05-01

Review 4.  Review on Development and Dental Applications of Polyetheretherketone-Based Biomaterials and Restorations.

Authors:  Ludan Qin; Shuo Yao; Jiaxin Zhao; Chuanjian Zhou; Thomas W Oates; Michael D Weir; Junling Wu; Hockin H K Xu
Journal:  Materials (Basel)       Date:  2021-01-15       Impact factor: 3.623

5.  PEEK Biomaterial in Long-Term Provisional Implant Restorations: A Review.

Authors:  Suphachai Suphangul; Dinesh Rokaya; Chatruethai Kanchanasobhana; Pimduen Rungsiyakull; Pisaisit Chaijareenont
Journal:  J Funct Biomater       Date:  2022-03-22
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.