| Literature DB >> 31485175 |
Nevin Çankaya1, İbrahim Bulduk2, Ayşen Melda Çolak3.
Abstract
Colchicum autumnale L. also known as the autumn crocus, contains colchicine alkaloid having antifungal properties. The tuber of this plant is rich in terms of colchicine. In this research an ultrasound-assisted extraction (UAE) method was optimized for the extraction of colchicine from Colchicum autumnale L. bulbs before high-performance liquid chromatography with UV detection (HPLC-UV). Optimization of various extraction parameters was performed using response surface methodology (RSM) to evaluate the maximum colchicine yield from Colchicum autumnale L. bulbs. The Box-Behnken design (BBD) and RSM were used to investigate the effect of three key parameters (extraction time (20-60 min), extraction temperature (40-80 °C) and ultrasound power (500-700 W) on extraction efficiency. The variance analysis suggested that the dependent response variable of yield of colchicine may be expressed by a quadratic polynomial model. The optimal theoretical extraction conditions were found to be an ultrasonication power of 602.4 W, an extraction time of 42 min and a temperature of 64 °C. Under these conditions, the optimum foreseen yield was 0.237%. The experimental colchicine yield obtained by following the optimized conditions was found to be 0.238%. These values are very well compatible with each other.Entities:
Keywords: Colchicine; Colchicum autumnale; HPLC; Response surface methodology; Ultrasound-assisted extraction (UAE)
Year: 2018 PMID: 31485175 PMCID: PMC6717106 DOI: 10.1016/j.sjbs.2018.10.003
Source DB: PubMed Journal: Saudi J Biol Sci ISSN: 2213-7106 Impact factor: 4.219
Validation parameters.
| Parameters | Colchicine | |
|---|---|---|
| Specify | Peak Purity Ratio | 0.0010 |
| Linearity | Concentration Range of Colchicine Standards ppm | 100–500 |
| Correlation Coefficient of Linearity Equation | 0.9996 | |
| Intercept of Linearity Equation | 57.68 | |
| Slope of Linearity Equation | 21.53 | |
| Limit of Detection (ppm) | 3.3731 | |
| Limit of Quantification (ppm) | 7.7390 | |
| Retention Time min. | 9.480 | |
Response surface analysis experimental data and experimental values.
| Run | Ext. Time | Ext. Temp. | Ultr. Power | Colchicine | Colchicine |
|---|---|---|---|---|---|
| 1 | 20 | 60 | 500 | 0.178 | 0.177 |
| 2 | 20 | 60 | 700 | 0.186 | 0.181 |
| 3 | 60 | 60 | 500 | 0.196 | 0.184 |
| 4 | 60 | 60 | 700 | 0.189 | 0.171 |
| 5 | 40 | 40 | 500 | 0.182 | 0.155 |
| 6 | 40 | 40 | 700 | 0.174 | 0.139 |
| 7 | 40 | 80 | 500 | 0.184 | 0.201 |
| 8 | 40 | 80 | 700 | 0.199 | 0.208 |
| 9 | 20 | 40 | 600 | 0.196 | 0.168 |
| 10 | 60 | 40 | 600 | 0.184 | 0.153 |
| 11 | 20 | 80 | 600 | 0.202 | 0.212 |
| 12 | 60 | 80 | 600 | 0.214 | 0.224 |
| 13 | 40 | 60 | 600 | 0.235 | 0.227 |
| 14 | 40 | 60 | 600 | 0.238 | 0.227 |
| 15 | 40 | 60 | 600 | 0.236 | 0.227 |
| 16 | 60 | 40 | 600 | 0.184 | 0.177 |
| 17 | 60 | 60 | 500 | 0.196 | 0.181 |
Fig. 1Effect of the pH on the extraction yield.
Fig. 2Effect of the solvent/material ratio on the extraction yield.
Fig. 3Effect of the ultrasonication time on the extraction yield.
Fig. 4Effect of the ultrasonication temperature on the extraction yield.
Variance analysis (ANOVA) for the response quadratic model.
| Source | Sum of squares | dF | Mean square | Significance | ||
|---|---|---|---|---|---|---|
| Model | 0.03300 | 9 | 0.00368 | 19.24 | 0.0023 | Significant |
| X1 | 0.00961 | 1 | 0.00961 | 50.21 | 0.0009 | Significant |
| X2 | 0.00565 | 1 | 0.00565 | 29.54 | 0.0029 | Significant |
| X3 | 0.01000 | 1 | 0.01000 | 53.00 | 0.0008 | Significant |
| X1X2 | 0.00255 | 1 | 0.00255 | 13.33 | 0.0147 | Significant |
| X1X3 | 0.00203 | 1 | 0.00203 | 10.58 | 0.0226 | Significant |
| X2X3 | 0.00009 | 1 | 0.00009 | 0.47 | 0.5228 | Not significant |
| X12 | 0.00618 | 1 | 0.00618 | 32.30 | 0.0023 | Significant |
| X22 | 0.01100 | 1 | 0.01100 | 56.61 | 0.0007 | Significant |
| X32 | 0.00995 | 1 | 0.00995 | 52.00 | 0.0008 | – |
| Residual | 0.00096 | 5 | 0.00019 | – | – | – |
| Lack of Fit | 0.00092 | 3 | 0.00031 | 18.86 | 0.0508 | Not significant |
| Pure Error | 0.00003 | 2 | 0.00002 | – | – | – |
| Cor Total | 0.03400 | 14 | – | – | – | – |
| R-Squared | 0.9719 | – | – | – | – | – |
| Adj R-Squared | 0.9214 | – | – | – | – | – |
Fig. 5The effect of ultrasound temperature and ultrasound time.
Fig. 6The effect of the ultrasound power and ultrasound temperature.
Fig. 7The effect of ultrasound power and ultrasound time.
Fig. 8The HPLC chromatogram of colchicine standard.
Fig. 9The HPLC chromatogram of extract of Colchicum autumnale L. bulbs.
Optimal extraction conditions, predicted and experimental results.
| Optimal conditions | Colchicine content | |||
|---|---|---|---|---|
| Extraction Time | Extraction Temperature | Ultr. Power | Experimental Result | Predicted Value |
| 42.3 min | 64.4 °C | 602.4 W | 0.238% | 0.237% |