Literature DB >> 31482363

Evaluation of continuous flash glucose monitoring in a pediatric ICU setting.

Eirini Kotzapanagiotou1, Eleni Tsotridou2, Eleni Volakli1, Meropi Dimitriadou2, Elpis Chochliourou1, Serafeia Kalamitsou1, Fani Kotzapanagiotou1, Maria Sdougka1, Athanasios Christoforidis3.   

Abstract

Glucose monitoring is of great importance among patients in intensive care units (ICU). The purpose of this study is to assess the performance of a new flash glucose monitoring (FGM) system in a pediatric ICU setting. Sixteen consecutive patients admitted in pediatric ICU aged > 4 years, expected length stay > 2 days and with no medication or existing diagnosis affecting glucose metabolism were enrolled. FreeStyle Libre sensor was applied to the upper arm of the patients (8 boys). FGM measurements were compared to 3 "references": arterial blood gas analysis, capillary blood analysis and biochemical serum analysis. Mean age of patients was 8.03 ± 2.91 years. Sensors remained in situ for a median of 9.71 ± 5.35 days. Removal of the sensor was mainly attributed to the completion of the predefine life-span of the sensor or discharge of the patient from the ICU. We compared 711 pairs of measurements between the sensor and other glucose measurement methods. Glucose values from the sensor were consistently lower with mean absolute relative difference (MARD) being 28.34%, 25.11% and 18.99% compared to the blood gas analyzer, capillary blood glucose meter, and biochemical serum analysis, respectively, but a wide interindividual variability. Significant linear correlations between age and MARD values were observed. Surveillance error grid (SEG) analysis showed 92.04%, 94.67% and 95.52% of the readings in the none or slight risk zone respectively. FreeStyle Libre is well tolerated although not adequately accurate with a tendency to underestimate glucose levels in critically ill pediatric patients.

Entities:  

Keywords:  CGM; Flash; Glucose; Intensive care unit; Pediatric

Year:  2019        PMID: 31482363     DOI: 10.1007/s10877-019-00384-y

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  5 in total

1.  Safety and Accuracy of Factory-Calibrated Continuous Glucose Monitoring in Pediatric Patients Undergoing Hematopoietic Stem Cell Transplantation.

Authors:  Jenna Sopfe; Tim Vigers; Laura Pyle; Roger H Giller; Gregory P Forlenza
Journal:  Diabetes Technol Ther       Date:  2020-03-17       Impact factor: 6.118

2.  Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline.

Authors:  Rodolfo J Galindo; Guillermo E Umpierrez; Robert J Rushakoff; Ananda Basu; Suzanne Lohnes; James H Nichols; Elias K Spanakis; Juan Espinoza; Nadine E Palermo; Dessa Garnett Awadjie; Leigh Bak; Bruce Buckingham; Curtiss B Cook; Guido Freckmann; Lutz Heinemann; Roman Hovorka; Nestoras Mathioudakis; Tonya Newman; David N O'Neal; Michaela Rickert; David B Sacks; Jane Jeffrie Seley; Amisha Wallia; Trisha Shang; Jennifer Y Zhang; Julia Han; David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2020-09-28

3.  The Effect of Various, Everyday Practices on Glucose Levels in Critically Ill Children.

Authors:  Eleni Tsotridou; Eirini Kotzapanagiotou; Asimina Violaki; Meropi Dimitriadou; Menelaos Svirkos; Peristera-Eleni Mantzafleri; Vasiliki Papadopoulou; Maria Sdougka; Athanasios Christoforidis
Journal:  J Diabetes Sci Technol       Date:  2020-10-07

4.  Accuracy of the intermittently scanned continuous glucose monitoring system in critically ill patients: a prospective, multicenter, observational study.

Authors:  Weifeng Huang; Siwan Li; Jingyi Lu; Yun Shen; Yaxin Wang; Yufei Wang; Kaixuan Feng; Xiaoli Huang; Yan Zou; Linjie Hu; Yihan Lu; Jian Zhou; Yingchuan Li
Journal:  Endocrine       Date:  2022-10-13       Impact factor: 3.925

5.  Accuracy and Stability of a Subcutaneous Flash Glucose Monitoring System in Critically Ill Patients.

Authors:  Hiromu Naraba; Tadahiro Goto; Mitsuhiro Tokuda; Tomohiro Sonoo; Hidehiko Nakano; Yuji Takahashi; Hideki Hashimoto; Kensuke Nakamura
Journal:  J Diabetes Sci Technol       Date:  2021-06-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.