| Literature DB >> 31480636 |
Ofonime N Ukweh1, Theophilus I Ugbem2, Chibuike M Okeke3, Ernest U Ekpo4,5.
Abstract
BACKGROUND: Ultrasound is operator-dependent, and its value and efficacy in fetal morphology assessment in a low-resource setting is poorly understood. We assessed the value and efficacy of fetal morphology ultrasound assessment in a Nigerian setting.Entities:
Keywords: congenital anomalies; morphology survey; morphology ultrasound; prenatal diagnosis
Year: 2019 PMID: 31480636 PMCID: PMC6787725 DOI: 10.3390/diagnostics9030109
Source DB: PubMed Journal: Diagnostics (Basel) ISSN: 2075-4418
Figure 1Distribution of anomalies detected.
Distribution of anomalies according to body systems.
| Body System Defects | Defects Detected on Ultrasound | Postnatal Diagnosis | Correctly Detected Using Ultrasound (%) |
|---|---|---|---|
| Nervous system | 35 (41.7%) | 38 (34.9%) | 92.1 |
| Genitourinary | 10 (11.9%) | 13 (11.9%) | 76.9 |
| Musculoskeletal | 9 (10.7%) | 12 (11.0%) | 75.0 |
| Digestive | 10 (11.9%) | 14 (12.8%) | 71.5 |
| Circulatory | 4 (4.8%) | 8 (7.3%) | 50.0 |
| Abdominal wall | 6 (7.1%) | 9 (8.3%) | 66.7 |
| Facial | 7 (8.3%) | 10 (9.2%) | 70.0 |
| Soft tissue | 3 (3.6%) | 5 (4.6%) | 60 |
| Total | 84 (100%) | 109 | Mean: 70.3 |
Figure 2Ultrasound features of fetal hydrops (A) and Cystic hygroma (B).
Figure 3Ultrasound image of anencephaly.
Average diagnostic efficacy across facilities.
| Performance Metrics | Value | 95% Confidence Interval |
|---|---|---|
| Sensitivity | 77.1 | 68.0–84.6 |
| Specificity | 99.5 | 99.3–99.7 |
| Positive Likelihood ratio | 254.4 | 107.7–221.4 |
| Negative Likelihood ratio | 0.23 | 0.16–0.33 |
| Abnormality prevalence | 1.67 * | 1.37–2.01 |
| Positive predictive value | 72.41 | 64.7–79.0 |
| Negative predictive value | 99.6 | 99.5–99.7 |
| Area Under Curve | 88.3 | 83.7–92.2 |
| Youden index | 77.1 |
* = The prevalence of anomalies is not representative of the true population prevalence. Therefore, these values should not be inferred to the population.
Summary of results across the five centers at 95% Confidence Interval.
| Centers | Sensitivity | Specificity | PLR | NLR | Prevalence | PPV | NPV | AUC | J |
|---|---|---|---|---|---|---|---|---|---|
| C1 | 58(28,85) | 99.7(99,100) | 209.7(49,907) | 0.42(0.21,0.82) | * 1.6(0.85,2.9) | 77.7(45,94) | 99.3(98.7,99.6) | 78.9(63.5,92.5) | 57.7 |
| C2 | 73(45,92) | 99.6(98.7,99.9) | 168.7(52,543) | 0.27(0.12,0.62) | * 2.1(1.2,3.5) | 78.6(53,93) | 99.4(98.7,99.8) | 86.3(71.5,95.6) | 72.6 |
| C3 | 78(56,93) | 99.5(99,100) | 160.6(65,395) | 0.22(0.1,0.47) | * 2.2(1.4,3.3) | 78.3(59,90) | 99.5(98.9,99.8) | 88.8(77.5,96.5) | 77.5 |
| C4 | 62(47,76) | 99.5(99,99.7) | 121(69,215) | 0.38(0.26,0.55) | * 1.6(1.2,2.2) | 66.7(53,78) | 99.8 (99,99.6) | 80.8(73.4,75.2) | 61.5 |
Numbers in brackets represent 95% confidence intervals. PLR: positive likelihood ratio; NLR: Negative likelihood ratio; PPV: positive predictive value; NPV: negative predictive value; AUC: Area Under the Curve. * = The prevalence of anomalies may not be representative of the true population prevalence. Therefore, these values should not be inferred to the population; J: Youden index.