Literature DB >> 31478950

Correlation Between Corneal Biomechanical Indices and the Severity of Keratoconus.

Shizuka Koh1,2, Ryota Inoue1,3, Renato Ambrósio4, Naoyuki Maeda2, Atsuya Miki2, Kohji Nishida2.   

Abstract

PURPOSE: To investigate the correlations between the biomechanical indices determined in Scheimpflug-based corneal biomechanical assessments and the severity of keratoconus (KC) based on corneal tomographic assessments in patients with different stages of KC.
METHODS: Fifty-three patients who presented with clinical KC in 1 eye and KC suspect in the fellow eye were included. Corneal tomographic and biomechanical assessments were performed using the Pentacam HR and Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany). Correlations between the tomographic indices and biomechanical indices were assessed, including the anterior radius of curvature (ARC) and posterior radius of curvature (PRC) at a 3.0-mm optical zone and the thinnest pachymetry (Tmin), deformation amplitude ratio max 2 mm (DAR2mm), integrated radius, stiffness parameter at the first applanation, and linear Corvis Biomechanical Index (beta).
RESULTS: DAR2mm correlated negatively with ARC (R = -0.722), PRC (R = -0.677), and Tmin (R= -0.650) (P < 0.001 for all). Integrated radius correlated negatively with ARC (R = -0.700), PRC (R = -0.668), and Tmin (R= -0.648) (P < 0.001 for all). Stiffness parameter at the first applanation correlated positively with ARC (R = 0.622), PRC (R = 0.601), and Tmin (R = 0.703) (P < 0.001 for all). The Corvis Biomechanical Index beta correlated negatively with ARC (R = -0.754), PRC (R = -0.755), and Tmin (R= -0.765) (P < 0.001 for all).
CONCLUSIONS: Corneal biomechanical indices correlated with corneal tomographic parameters in patients with KC. These findings support the possibility of developing biomechanical-based staging classification for KC in combination with topographic or tomographic indices.

Entities:  

Mesh:

Year:  2020        PMID: 31478950     DOI: 10.1097/ICO.0000000000002129

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  4 in total

1.  Association between Corneal Stiffness Parameter at the First Applanation and Keratoconus Severity.

Authors:  Kaili Yang; Liyan Xu; Qi Fan; Shengwei Ren
Journal:  J Ophthalmol       Date:  2020-12-02       Impact factor: 1.909

2.  Accuracy of new Corvis ST parameters for detecting subclinical and clinical keratoconus eyes in a Chinese population.

Authors:  Shengwei Ren; Liyan Xu; Qi Fan; Yuwei Gu; Kaili Yang
Journal:  Sci Rep       Date:  2021-03-02       Impact factor: 4.379

3.  Relationship between corneal biomechanical parameters and corneal sublayer thickness measured by Corvis ST and UHR-OCT in keratoconus and normal eyes.

Authors:  Yong Li; Zhiqiang Xu; Qiaoli Liu; Yuzhou Wang; Kan Lin; Jiahui Xia; Shihao Chen; Liang Hu
Journal:  Eye Vis (Lond)       Date:  2021-01-08

4.  A Potential Screening Index of Corneal Biomechanics in Healthy Subjects, Forme Fruste Keratoconus Patients and Clinical Keratoconus Patients.

Authors:  Lei Tian; Xiao Qin; Hui Zhang; Di Zhang; Li-Li Guo; Hai-Xia Zhang; Ying Wu; Ying Jie; Lin Li
Journal:  Front Bioeng Biotechnol       Date:  2021-12-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.