Accuracy of a central mass spectrometer system at high respiratory frequencies.

F L Scamman1.   

Abstract

We have shown that in a laboratory setting the long lengths of sampling catheters necessary to access a central mass spectrometer restrict the high-frequency response of the system. Reported here are the results from a clinically operating Perkin-Elmer Advantage system. The sampling catheter was 50 meters long and the sampling flow was 240 ml/min. Rapid changes in carbon dioxide concentration were created by an electronically operated solenoid valve switching between 6.94% CO2 in 50% O2 balance N2 and 100% O2. The frequency of this simulated breathing was varied between 10 and 100 breaths/min with the ratio of inspiration to expiration fixed at 1:2. Data were taken from the terminal in the operating room. Errors greater than 5% of the true value occurred at 35 breaths/min for the indicated inspired concentration and 73 breaths/min for the indicated expired concentration. For critical situations in which respiratory frequencies exceed 40 breaths/min, a centrally located mass spectrometer may not be adequate for measuring CO2 because of errors introduced by the long sampling catheters.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3145330     DOI: 10.1007/bf01621822

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  3 in total

1.  Frequency response of long mass-spectrometer sampling catheters.

Authors:  F L Scamman; J K Fishbaugh
Journal:  Anesthesiology       Date:  1986-10       Impact factor: 7.892

2.  Factors influencing capnography in the Bain circuit.

Authors:  N Gravenstein; S Lampotang; J E Beneken
Journal:  J Clin Monit       Date:  1985-01

3.  Accuracy of expiratory carbon dioxide measurements using the coaxial and circle breathing circuits in small subjects.

Authors:  R A Schieber; A Namnoum; A Sugden; A L Saville; R A Orr
Journal:  J Clin Monit       Date:  1985-07
  3 in total
  4 in total

1.  Erroneous mass spectrometer data caused by a faulty patient sampling tube: case report and laboratory study.

Authors:  T M Skeehan; J F Biebuyck
Journal:  J Clin Monit       Date:  1991-10

2.  Evaluation of long sampling tubes for remote monitoring by mass spectrometry.

Authors:  J G Lerou; J van Egmond; H H Beneken Kolmer
Journal:  J Clin Monit       Date:  1990-01

3.  Mass spectrometry: performance of long catheters.

Authors:  J G Lerou; J van Egmond
Journal:  J Clin Monit       Date:  1993-01

4.  Use of long catheters for multipatient anesthetic monitoring at high respiratory frequencies.

Authors:  J C Turner
Journal:  J Clin Monit       Date:  1991-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.