Frequency response of long mass-spectrometer sampling catheters.

F L Scamman, J K Fishbaugh.   

Abstract

It was hypothesized that the long lengths of sampling catheters required when a mass spectrometer is multiplexed to more than one operating room limit the upper frequency at which a gas concentration may be determined accurately. This possibility has not been investigated. Known step changes of CO2 were generated by a solenoid valve driven by an electronic timer that was adjustable from 0.1 to 10 Hz. The valve alternated between 100% O2 and 7% CO2 in 50% O2 and balance N2. CO2 concentration was monitored by a mass spectrometer after the gas passed through a 3.7 m Teflon catheter or through 30 m Teflon, nylon, polyethylene (PE), or polyvinylchloride (PVC) catheters. Gas flow for all catheters was adjusted to 1.1 ml/s. The peak-to-peak output of the mass spectrometer was read from a storage oscilloscope. The 3.7 m catheter caused a 10% error at 5.5 Hz (330/min). In sharp contrast, 30 m catheters made from Teflon, PVC, and PE caused errors greater than 10% at only 0.6 Hz (36/min). The 30 m nylon catheter passed 1.1 Hz (66/min) with a 10% error. Teflon, PVC, and PE are not suitable materials from which to make long catheters sampling CO2. Because the frequency response of the nylon catheter appeared similar to that of a low-pass filter, an electronic circuit was designed and tuned to extend the high-frequency response of the catheter. With the circuit in place, the frequency at which a 10% error occurred in the measurement of CO2 improved from 1.1 Hz (66/min) to 2.2 Hz (132/min).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3094408     DOI: 10.1097/00000542-198610000-00013

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  6 in total

1.  Erroneous mass spectrometer data caused by a faulty patient sampling tube: case report and laboratory study.

Authors:  T M Skeehan; J F Biebuyck
Journal:  J Clin Monit       Date:  1991-10

2.  Evaluation of long sampling tubes for remote monitoring by mass spectrometry.

Authors:  J G Lerou; J van Egmond; H H Beneken Kolmer
Journal:  J Clin Monit       Date:  1990-01

3.  A small bypass mixing chamber for monitoring metabolic rate and anesthetic uptake: the bymixer.

Authors:  Y Sanjo; K Ikeda
Journal:  J Clin Monit       Date:  1987-10

4.  Mass spectrometry: performance of long catheters.

Authors:  J G Lerou; J van Egmond
Journal:  J Clin Monit       Date:  1993-01

5.  Weaning from ventilation after cardiopulmonary bypass: evaluation of a non-invasive technique.

Authors:  D E Withington; J G Ramsay; A T Saoud; J Bilodeau
Journal:  Can J Anaesth       Date:  1991-01       Impact factor: 5.063

6.  Accuracy of a central mass spectrometer system at high respiratory frequencies.

Authors:  F L Scamman
Journal:  J Clin Monit       Date:  1988-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.