Literature DB >> 31442968

Enhanced Detection of Bubble Emissions Through the Intact Spine for Monitoring Ultrasound-Mediated Blood-Spinal Cord Barrier Opening.

Stecia-Marie P Fletcher, Natalia Ogrodnik, Meaghan A O'Reilly.   

Abstract

OBJECTIVE: We previously developed short burst, phase keying (SBPK) focused ultrasound (FUS) to mitigate standing waves in the human vertebral canal. Here, we show microbubble emissions from these pulses can be detected through the human vertebral arch and that these pulses are effective for blood-spinal cord barrier (BSCB) opening.
METHODS: At f0 = 514 kHz, circulating microbubbles were sonicated through ex vivo human vertebrae (60 kPa-1 MPa) using a dual-aperture approach and SBPK exposures engineered to incorporate pulse inversion (PI). Signals from a 250 kHz receiver were analyzed using PI, short-time Fourier analysis and the maximum projection over the pulse train. In rats (n = 14), SBPK FUS+microbubbles was applied to 3 locations/spinal cord at fixed pressures (∼0.20-0.47 MPa). MRI and histology were used to assess opening and tissue damage.
RESULTS: In human vertebrae between 0.2-0.4 MPa, PI amplified the microbubble/baseline ratio at f0/2 and 2f0 by 202 ± 40% (132-291%). This was maximal at 0.4 MPa, coinciding with the onset of broadband emissions. In vivo, opening was achieved at 40/42 locations, with mean MRI enhancement of 46 ± 32%(16%-178%). Using PI, f0/2 was detected at 14/40 opening locations. At the highest pressures (f0/2 present) histology showed widespread bleeding throughout the focal region. At the lowest pressures, opening was achieved without bleeding.
CONCLUSION: This study confirmed that PI can increase sensitivity to transvertebral detection of microbubble signals. Preliminary in vivo investigations show that SBPK FUS can increase BSCB permeability without tissue damage. SIGNIFICANCE: SBPK is a clinically relevant pulse scheme and, in combination with PI, provides a means of mediating and monitoring BSCB opening noninvasively.

Entities:  

Mesh:

Year:  2019        PMID: 31442968      PMCID: PMC7251956          DOI: 10.1109/TBME.2019.2936972

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  42 in total

1.  Cellular mechanisms of the blood-brain barrier opening induced by ultrasound in presence of microbubbles.

Authors:  Nickolai Sheikov; Nathan McDannold; Natalia Vykhodtseva; Ferenc Jolesz; Kullervo Hynynen
Journal:  Ultrasound Med Biol       Date:  2004-07       Impact factor: 2.998

2.  The impact of standing wave effects on transcranial focused ultrasound disruption of the blood-brain barrier in a rat model.

Authors:  Meaghan A O'Reilly; Yuexi Huang; Kullervo Hynynen
Journal:  Phys Med Biol       Date:  2010-08-18       Impact factor: 3.609

3.  In vivo transcranial cavitation threshold detection during ultrasound-induced blood-brain barrier opening in mice.

Authors:  Yao-Sheng Tung; Fotios Vlachos; James J Choi; Thomas Deffieux; Kirsten Selert; Elisa E Konofagou
Journal:  Phys Med Biol       Date:  2010-09-29       Impact factor: 3.609

4.  Noninvasive and localized neuronal delivery using short ultrasonic pulses and microbubbles.

Authors:  James J Choi; Kirsten Selert; Fotios Vlachos; Anna Wong; Elisa E Konofagou
Journal:  Proc Natl Acad Sci U S A       Date:  2011-09-19       Impact factor: 11.205

5.  A Spine-Specific Phased Array for Transvertebral Ultrasound Therapy: Design and Simulation.

Authors:  Rui Xu; Meaghan A O'Reilly
Journal:  IEEE Trans Biomed Eng       Date:  2019-04-18       Impact factor: 4.538

6.  Pulse inversion enhances the passive mapping of microbubble-based ultrasound therapy.

Authors:  Antonios N Pouliopoulos; Mark T Burgess; Elisa E Konofagou
Journal:  Appl Phys Lett       Date:  2018-07-24       Impact factor: 3.791

7.  Noninvasive MR imaging-guided focal opening of the blood-brain barrier in rabbits.

Authors:  K Hynynen; N McDannold; N Vykhodtseva; F A Jolesz
Journal:  Radiology       Date:  2001-09       Impact factor: 11.105

8.  Multiple treatments with liposomal doxorubicin and ultrasound-induced disruption of blood-tumor and blood-brain barriers improve outcomes in a rat glioma model.

Authors:  Muna Aryal; Natalia Vykhodtseva; Yong-Zhi Zhang; Juyoung Park; Nathan McDannold
Journal:  J Control Release       Date:  2013-04-18       Impact factor: 9.776

9.  Noninvasive and targeted gene delivery into the brain using microbubble-facilitated focused ultrasound.

Authors:  Po-Hung Hsu; Kuo-Chen Wei; Chiung-Yin Huang; Chih-Jen Wen; Tzu-Chen Yen; Chao-Lin Liu; Ya-Tin Lin; Jin-Chung Chen; Chia-Rui Shen; Hao-Li Liu
Journal:  PLoS One       Date:  2013-02-27       Impact factor: 3.240

10.  Three-dimensional transcranial microbubble imaging for guiding volumetric ultrasound-mediated blood-brain barrier opening.

Authors:  Ryan M Jones; Lulu Deng; Kogee Leung; Dallan McMahon; Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Theranostics       Date:  2018-04-16       Impact factor: 11.556

View more
  3 in total

1.  A Porcine Model of Transvertebral Ultrasound and Microbubble-Mediated Blood-Spinal Cord Barrier Opening.

Authors:  Stecia-Marie P Fletcher; Min Choi; Natalia Ogrodnik; Meaghan A O'Reilly
Journal:  Theranostics       Date:  2020-06-19       Impact factor: 11.556

2.  Delayed Onset Muscle Soreness (DOMS): The Repeated Bout Effect and Chemotherapy-Induced Axonopathy May Help Explain the Dying-Back Mechanism in Amyotrophic Lateral Sclerosis and Other Neurodegenerative Diseases.

Authors:  Balázs Sonkodi
Journal:  Brain Sci       Date:  2021-01-15

3.  Characterization of ultrasound-mediated delivery of trastuzumab to normal and pathologic spinal cord tissue.

Authors:  Paige Smith; Natalia Ogrodnik; Janani Satkunarajah; Meaghan A O'Reilly
Journal:  Sci Rep       Date:  2021-02-24       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.