Literature DB >> 31408366

Effect of micro-computed tomography reconstruction protocols on bone fractal dimension analysis.

Hugo Gaêta-Araujo1, Nicolly Oliveira-Santos1, Danieli Moura Brasil1, Eduarda Helena Leandro do Nascimento1, Daniela Verardi Madlum1, Francisco Haiter-Neto1, Christiano de Oliveira-Santos2.   

Abstract

OBJECTIVES: To evaluate the influence of the level of three micro-CT reconstruction tools: beam-hardening correction (BHC), smoothing filter (SF), and ring artefact correction (RAC) on the fractal dimension (FD) analysis of trabecular bone.
METHODS: Five Wistar rats' maxillae were individually scanned in a SkyScan 1174 micro-CT device, under the following settings: 50 kV, 800 µA, 10.2 µm voxel size, 0.5 mm Al filter, rotation step 0.5°, two frames average, 180° rotation and scan time of 35 min. The raw images were reconstructed under the standard protocol (SP) recommended by the manufacturer, a protocol without any artefact correction tools (P0) and 35 additional protocols with different combinations of SF, RAC and BHC levels. The same volume of interest was established in all reconstructions for each maxilla and the FD was calculated using the Kolmogorov (box counting) method. One-way ANOVA with Dunnet's post-hoc test was used to compare the FD of each reconstruction protocol (P0-P35) with the SP (α = 5%). Multiple linear regression verified the dependency of reconstruction tools in FD.
RESULTS: Overall, FD values are not dependent on RAC (p = 0.965), but increased significantly when the level of BHC and SF increased (p < 0.001). FD values from protocols with BHC at 45% combined with SF of 2, and BHC at 30% combined with SF of 4 or 6 had no statistical difference compared to SP.
CONCLUSIONS: BHC and SF tools affect the FD values of micro-CT images of the trabecular bone. Therefore, these reconstruction parameters should be standardized when the FD is analyzed.

Entities:  

Keywords:  3 D Imaging; Fractals; Microcomputed Tomography; X-Ray

Mesh:

Year:  2019        PMID: 31408366      PMCID: PMC6951094          DOI: 10.1259/dmfr.20190235

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  21 in total

1.  Fractal dimension of trabecular bone: comparison of three histomorphometric computed techniques for measuring the architectural two-dimensional complexity.

Authors:  D Chappard; E Legrand; B Haettich; G Chalès; B Auvinet; J P Eschard; J P Hamelin; M F Baslé; M Audran
Journal:  J Pathol       Date:  2001-11       Impact factor: 7.996

Review 2.  Guidelines for assessment of bone microstructure in rodents using micro-computed tomography.

Authors:  Mary L Bouxsein; Stephen K Boyd; Blaine A Christiansen; Robert E Guldberg; Karl J Jepsen; Ralph Müller
Journal:  J Bone Miner Res       Date:  2010-07       Impact factor: 6.741

3.  Assessment of cancellous bone structure: comparison of strut analysis, trabecular bone pattern factor, and marrow space star volume.

Authors:  P I Croucher; N J Garrahan; J E Compston
Journal:  J Bone Miner Res       Date:  1996-07       Impact factor: 6.741

4.  The Accuracy of Cone-Beam Computed Tomography for Evaluating Bone Density and Cortical Bone Thickness at the Implant Site: Micro-Computed Tomography and Histologic Analysis.

Authors:  Srisurang Suttapreyasri; Pradipat Suapear; Narit Leepong
Journal:  J Craniofac Surg       Date:  2018-11       Impact factor: 1.046

5.  Application of fractal dimension for quantifying noise texture in computed tomography images.

Authors:  P Khobragade; Jiahua Fan; Franco Rupcich; Dominic J Crotty; Taly Gilat Schmidt
Journal:  Med Phys       Date:  2018-06-09       Impact factor: 4.071

Review 6.  The role of micro-computed tomography in forensic investigations.

Authors:  G N Rutty; A Brough; M J P Biggs; C Robinson; S D A Lawes; S V Hainsworth
Journal:  Forensic Sci Int       Date:  2012-11-13       Impact factor: 2.395

7.  Comparison of fractal dimension analysis and panoramic-based radiomorphometric indices in the assessment of mandibular bone changes in patients with type 1 and type 2 diabetes mellitus.

Authors:  Emine Şebnem Kurşun-Çakmak; Seval Bayrak
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2018-05-03

8.  Assessment of the trabecular structure of mandibular condyles in patients with temporomandibular disorders using fractal analysis.

Authors:  Belde Arsan; Taha Emre Köse; Erhan Çene; İlknur Özcan
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2016-11-22

9.  Segmentation Methods for Micro CT Images: A Comparative Study Using Human Bone Samples.

Authors:  Karla Rovaris; Polyane Mazucatto Queiroz; Karla de Faria Vasconcelos; Lívia Dos Santos Corpas; Bernardo Mattos da Silveira; Deborah Queiroz Freitas
Journal:  Braz Dent J       Date:  2018 Mar-Apr

10.  A Ring Artifact Correction Method: Validation by Micro-CT Imaging with Flat-Panel Detectors and a 2D Photon-Counting Detector.

Authors:  Mohamed Elsayed Eldib; Mohamed Hegazy; Yang Ji Mun; Myung Hye Cho; Min Hyoung Cho; Soo Yeol Lee
Journal:  Sensors (Basel)       Date:  2017-01-30       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.