Segmentation Methods for Micro CT Images: A Comparative Study Using Human Bone Samples.

Karla Rovaris1, Polyane Mazucatto Queiroz1, Karla de Faria Vasconcelos1, Lívia Dos Santos Corpas2, Bernardo Mattos da Silveira3, Deborah Queiroz Freitas1.   

Abstract

X-ray microtomography (microCT) is a nondestructive technique used to assess bone morphometry. For an accurate analysis, it is necessary to segment the bone tissue from the background images, avoiding under- or overestimation of the real bone volume. Thus, segmentation methods for microCT can influence the accuracy of bone morphometry analysis. The purpose of this study was to compare two different image segmentation methods available on microCT software (subjective and objective) regarding to the human bone morphometric analysis. Sixteen samples containing a fixation screws covered by 0.5-1mm of bone were scanned using the SkyScan 1173 scanner. Three examiners segmented the microCT images subjectively and recorded the threshold values. Subsequently, an objective segmentation was also done. The 3D analysis was performed for both images using the values​ previously determined in CTAn software. Five bone morphometric parameters were calculated (BV/TV, Tb.Th, Tb.N, Tb.Sp, Conn.Den) and used as dependent variables. ANOVA showed no significant differences between the methods concerning BV/TV (p=0.424), Tb.N (p=0.672), Tb.Th (p=0.183), Tb.Sp (p=0.973) and Conn.Den (p=0.204). Intra- and interobserver agreement ranged from satisfactory to excellent (0.55-1 and 0.546-0.991, respectively). Therefore, results obtained with subjective threshorlding were similar to those obtained with objective segmentation. Since objective segmentation does not have human input and it is a truly objective method, it should be the first choice in microCT studies that concern homogeneity and high resolution human bone sample.

Entities:  

Mesh:

Year:  2018        PMID: 29898060     DOI: 10.1590/0103-6440201801385

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  3 in total

1.  Effect of micro-computed tomography reconstruction protocols on bone fractal dimension analysis.

Authors:  Hugo Gaêta-Araujo; Nicolly Oliveira-Santos; Danieli Moura Brasil; Eduarda Helena Leandro do Nascimento; Daniela Verardi Madlum; Francisco Haiter-Neto; Christiano de Oliveira-Santos
Journal:  Dentomaxillofac Radiol       Date:  2019-08-13       Impact factor: 2.419

2.  How image-processing parameters can influence the assessment of dental materials using micro-CT.

Authors:  Fernanda Ferrari Esteves Torres; Reinhilde Jacobs; Mostafa EzEldeen; Karla de Faria-Vasconcelos; Juliane Maria Guerreiro-Tanomaru; Bernardo Camargo Dos Santos; Mário Tanomaru-Filho
Journal:  Imaging Sci Dent       Date:  2020-06-18

3.  3D-printed saw guides for lower arm osteotomy, a comparison between a synthetic CT and CT-based workflow.

Authors:  Koen Willemsen; Mirte H M Ketel; Frank Zijlstra; Mateusz C Florkow; Ruurd J A Kuiper; Bart C H van der Wal; Harrie Weinans; Behdad Pouran; Freek J Beekman; Peter R Seevinck; Ralph J B Sakkers
Journal:  3D Print Med       Date:  2021-04-29
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.