Literature DB >> 31406478

Marginal bone loss 1 year after implantation: a systematic review for fixed and removable restorations.

Jennifer Zimmermann1, Melanie Sommer1, Leticia Grize2,3, Stefan Stubinger1.   

Abstract

This systematic review analyses the difference of the mean marginal bone loss (MBL) 1 year after implantation depending on the fixation of the restoration. 889 publications on controlled clinical trials were identified, and based on inclusion and exclusion criteria, 22 studies were selected. Related to fixed restorations, the lowest MBL was 0.05±0.67 mm and the highest 1.37±0.5 mm. The MBL for removable restorations ranged from 0.13±0.35 mm to 1.03±0.65 mm. Three studies analyzed the MBL around implants of overdentures in the lower jaw. The estimate for this restoration type was 0.476 mm (95% CI: -0.305 to 1.258). 19 randomized controlled studies dealt with restorations which were fixed to the implants. The estimate for the mean MBL was 0.459 mm (95% CI: 0.325-0.593). There was a decrease in 1-year implant survival with an increase of 1 mm MBL (-0.083%; 95% CI: -0.179 to 0.0123; p=0.083) in fixed restorations. The difference in MBL between fixed and removable restorations was 0.363 mm (95% CI: -0.319 to 1.044; p=0.279). This systematic review indicates that implants with fixed and with removable restorations lead to comparable MBL.

Entities:  

Keywords:  dental implants; fix and removable restorations; marginal bone loss; systematic review

Year:  2019        PMID: 31406478      PMCID: PMC6642649          DOI: 10.2147/CCIDE.S208076

Source DB:  PubMed          Journal:  Clin Cosmet Investig Dent        ISSN: 1179-1357


Introduction

Edentulous patients using a conventional prosthesis suffer the loss of mastication, articulation and insufficient retention. Furthermore, this problem causes pain, loss of soft-tissue support and general dissatisfaction.1 Masticatory efficiency is restricted to people in possession of complete dentures, namely <20% of the masticatory performance compared to those with natural dentition. One option to overcome this issue is the use of endosseous implants.2 An established frequently used therapy enables the attachment of the dental implant with a denture.3 Van Blarcom4 defined dental implant as A prosthetic device made of allo-plastic material(s) implanted into the oral tissues beneath the mucosal or/and periosteal layer, and on/or within the bone to provide retention and support for a fixed or removable dental prosthesis; a substance that is placed into or/and upon the jaw bone to support a fixed or removable dental prosthesis. By connecting the overdenture to the dental implant, the oral health-related quality of life (OHRQoL) improves as well as the masticatory forces increase.5 The removable fixation of an overdenture on two implants either splinted or unsplinted is a worldwide accepted medical treatment proven by long-term studies.6,7 Selim et al conclude in their review that the patient satisfaction of implant-supported fixed prostheses in the mandible is higher compared to the implant-supported removable overdentures. In contrast, implant-supported removable overdentures in the maxilla reach higher scores than the implant-supported fixed prostheses. The following factors are discussed: esthetics, stability, mastication performance, and pronunciation. In addition to keeping the prosthesis clean, implant-supported removable overdentures in the maxilla and mandible show favorable results.8 Strietzel et al check the implant loss of many different types of restorations, for example, single-tooth replacement, fixed partial denture, removable partial denture and overdenture. There is no statistically significant difference between the various types of restorations with respect to implant loss.9 For this reason, it is important to choose carefully which restoration is the most beneficial for the patient. Therefore, the clinician has to consider many factors before starting treatment, such as expenses, amount, arrangement and implant location, existing bone quality and quantity, maxilla–mandibular relationship, condition of the opposing dentition and time frame.10,11 To date, there is little evidence about the relation between marginal bone loss (MBL) and implant-supported fixed or removable prostheses in medical publications. This systematic review was conducted to evaluate the outcome of the mean MBL, implant and prosthesis success 1 year after implantation depending on the fixation of the restoration.

Materials and methods

The present review and meta-analysis were performed according to the PRISMA guidelines.12 To define the research question clearly and to facilitate the process of performing the review, the PICOS approach was used. This approach is based on five components: population, interventions, comparator, outcomes and study design. The specific components for this review are: P (Population): patients need at least one implant I (Interventions): fixed-removable restorations C (Comparator): the comparator groups were unattended O (Outcomes): mean MBL S (Study design): randomized controlled studies

Search strategy

The prevailing literature overview was based on a literature search in PubMed via MEDLINE, EMBASE and Cochrane library – the Cochrane Central Register of Controlled Trials (CENTRAL) to identify relevant publications to answer the research question. The studies could be written in any language and should be published between January 2000 and February 2017. The last search was on March 3, 2017, by using MeSH (Medical Subject Heading) and [ALL FIELDS] terms. The following search terms and combinations were used: “bone loss” AND “dental implantation”[MeSH Terms] AND “follow up”; OR (“bone resorption”[MeSH Terms] AND “dental implantation”[MeSH Terms] AND “follow up”); OR (“bone loss” AND “dental implants”[MeSH Terms] AND “follow up”); OR (“bone resorption”[MeSH Terms] AND “dental implants”[MeSH Terms] AND “follow up”). The search was limited to the following filters: Humans; Randomised controlled studies.

Inclusion criteria

The following study design criteria were included in the publications search: “randomised controlled study” and “follow-up one year after implantation”. Criteria used to compare the test and control groups: mean age of groups, number of inserted implants, group size, loading protocol (further details see13), fixed or removable restoration, implant manufacturer, treatment of implant surface (additive, subtractive, combination of additive and subtractive, combination of different subtractive treatments), survival rate based on implants and mean MBL were further requirements for inclusion.

Exclusion criteria

Exclusions to the trail were: “studies on animals or in vitro”; “reviews”; “case reports” and “clinical trials”; “follow-up one year post-loading”; and “missing data on the above-mentioned groups”.

Data extractions

Two independently working reviewers (JZ and MS) extracted the data from the full text for analysis. Both reviewers double-checked the acquired information. Discrepancies were solved by mutual agreement. While reviewing the publications a chart was created and consecutively updated. The following parameters were extracted and inserted in a chart: Title Author Year of publication Topic of the publication Number of implants Mean age of groups Number of patients participating Number of patients subdivided into groups If fixed or removable restoration Loading protocol (immediate loading, immediate nonocclusal loading, early loading, conventional loading) Implant manufacturer Treatment of implant surface (additive, subtractive, combination of additive and subtractive, combination of different subtractive treatments) Survival and success rate 1 year after implantation Mean MBL with SD Complications of the inserted implants and restorations

Definitions

In the literature, fixed restorations are described as screwed or cemented connection of the abutment to the implant body. Removable prostheses are fixed using a specific retention element to the implant.14

Statistical analysis

In this review, language bias is non-existent, because the identified studies are written exclusively in English. Moreover, the authors tried to minimize the risk of bias by only including randomized controlled studies. Publication bias might exist because there was no access to unpublished studies. The overall MBL estimates for fixed and removable restorations were calculated using DerSimonian–Laird models random-effects meta-analysis. The Egger’s test was performed to check for publication bias and the Cochran Q for heterogeneity. The association between 1-year implant survival and MBL was examined using metaregression models. The difference in meta-analytic estimates between removable and fixed restorations was tested with a metaregression including all studies using a dichotomous indicator to distinguish both restoration types. Because of the lack of information on implant success or complications in most of the studies, it was not possible to determine their relationship with MBL. Meta-analysis and metaregression were performed using STATA v.14.0 (StataCorp LP, 2015, College Station, TX, USA).

Results

For creating the review, the authors used the same data referring to the searching of the three databases as shown in a previous review “Marginal bone loss one year after implantation – A systematic review for different loading protocols“ (Figure 1).13 22 studies (240 implants for removable restorations and 2,096 implants for fixed restorations) were included in this review.
Figure 1

Search strategy.

Search strategy. Note: The article was published in Int J Oral Maxillofac Surg, Sommer M, Zimmermann J, Grize L, Stubinger S, Marginal bone loss one year after implantation – a systematic review for different loading protocols, Copyright Elsevier 2019.13

Description of studies

All listed studies had an observation period of 1 year after implantation using intraoral periapical radiographs (Table 1).13
Table 1

List of selected studies13

YearFirst authorControl/test groupNumber of implantsMean age in years (range)Number of patients in groupsFixed/removableLoading protocolImplant typeImplant surfaceSuccess rate implantsSuccess rate prosthesesReported complications
2011Alsabeeha NH15Neoss Regular Implants and locator attachment1270 (NR)12RemovableEarly loaded (>2 days to <3 months)Neoss Regular (Neoss Ltd., Harrogate, UK)Combination of subtractive methods100%Overdenture with locator: 66.7%,NR
2011Alsabeeha NH15Southern Regular Implants and standard ball attachment1264 (NR)12RemovableEarly loaded (>2 days to <3 months)Southern Regular (Southern Implants, Irene, South Africa)Combination of subtractive methods75%Overdenture with standard ball attachment: 63.6%NR
2011Alsabeeha NH15Southern 8-mm-wide Implants and large ball attachment1269 (NR)12RemovableEarly loaded (>2 days to <3 months)Southern wide (Southern Implants, Irene, South Africa)Combination of subtractive methods100%Overdenture with large ball attachment: 83.3%,NR
2008Cannizzaro G30Flapless placed implants immediately loaded with full-arch prostheses9062 (NR)15FixedImmediately loaded (<48 hrs)SwissPlus Tapered (Zimmer Dental, Carlsbad, USA)Subtractive method98.88%NRSoft-tissue ulcers induced by provisional, fracture or loosening of the provisional, fracture of the ceramic of final prosthesis, temperomandibular joint/occlusal/mastication problems, peri-implant tissue complications (total: 8)
2008Cannizzaro G30Flapless placed implants early loaded at 2 months with full-arch prostheses8756 (NR)15FixedEarly loaded (>2 days to <3 months)SwissPlus Tapered (Zimmer Dental, Carlsbad, USA)Subtractive method96.66%NRFracture or loosening of the provisional, temperomandibular joint/occlusal/mastication problems, peri-implant tissue complications, esthetic problems (total: 5)
2013Cannizzaro G372 implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screw-retained cross-arch prostheses6063 (37–83)30FixedImmediately loaded (<48 hrs)Tapered NT Full Osseotite (Biomet 3i, Palm Beach Gardens, USA); ExFeel (MegaGen Implant Co. Limited, Gyeongbuk, South Korea)Subtractive and additive method/subtractive methodNRNRMetal framework not fitting, occlusion to be adjusted, abutment screw loosening, resin tooth detachment/fracture, distal extension framework fracture, patient unsatisfied (total: 16)
2013Cannizzaro G374 implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screw-retained cross-arch prostheses12056 (39–71)30FixedImmediately loaded (<48 hrs)Tapered NT Full Osseotite (Biomet 3i, Palm Beach Gardens, USA); ExFeel (MegaGen Implant Co. Limited, Gyeongbuk, South Korea)Subtractive and additive method/subtractive methodNRNR
2015Cannizzaro G41Prostheses supported by supershort (5 mm) implants: maxilla9058.9 (44–78)15FixedImmediately loaded (<48 hrs)NanoTite (Biomet 3i, Palm Beach Gardens, USA)Subtractive and additive methodNRNRProsthesis screw loosening, hypoplastic soft tissue with ulcers, fracture of long distal cantilever, detachment of central incisors
2015Cannizzaro G41Prostheses supported by supershort (5 mm) implants: mandible6062.9 (47–80)15FixedImmediately loaded (<48 hrs)NanoTite (Biomet 3i, Palm Beach Gardens, USA)Subtractive and additive methodNRNR
2015Cannizzaro G41Prostheses supported by long (11.5 mm) implants: maxilla9058.5 (43–72)15FixedImmediately loaded (<48 hrs)Tapered NT NanoTite (Biomet 3i, Palm Beach Gardens, USA)Subtractive and additive methodNRNR
2015Cannizzaro G41Prostheses supported by long (11.5 mm) implants: mandible6058.8 (38–72)15FixedImmediately loaded (<48 hrs)Tapered NT NanoTite (Biomet 3i, Palm Beach Gardens, USA)Subtractive and additive methodNRNR
2015Cooper LF18Conical implant–abutment interface5343 (18–70)48FixedImmediately nonocclusally loadedOsseoSpeed (Astra Tech AB, Molndal, Sweden)Subtractive and additive methodNRNRNR
2015Cooper LF18Flat to flat implant–abutment-interface5346 (19–78)49FixedImmediately nonocclusally loadedNobel Speedy Replace (Nobel Biocare AB, Goteborg, Sweden)Subtractive and additive methodNRNRNR
2015Cooper LF18Platform-switched implant–abutment interface5046 (18–81)44FixedImmediately nonocclusally loadedNanoTite Certain Prevail (Biomet 3i, Palm Beach Gardens, USA)Subtractive and additive methodNRNRNR
2010Cooper LF21Single implants placed in fresh extraction sockets5845.1 (NR)55FixedImmediately nonocclusally loadedOsseoSpeed (Astra Tech AB, Molndal, Sweden)Subtractive and additive methodNRNRNR
2010Cooper LF21Single implants placed in healed ridges6542.1 (NR)58FixedImmediately nonocclusally loadedOsseoSpeed (Astra Tech AB, Molndal, Sweden)Subtractive and additive methodNRNRNR
2015Esposito M42Implant surface roughened with sandblasting and double etching13763.6 (47–80)25FixedImmediately loaded (<48 hrs)iRES iPerio (iRES SAGL, Lugano, Switzerland)Combination of subtractive methodsNRNRNone
2015Esposito M42Machined, turned implant surface16360.84 (38–81)25FixedImmediately loaded (<48 hrs)iRES iPerio (iRES SAGL, Lugano, Switzerland)Machined surfaceNRNRNone
2012Grandi T35Implants immediately loaded and restored using definitive abutments2853.2 (43–64)14FixedImmediately nonocclusally loadedJDEvolution (JDental Care S.r.l., Modena, Italy)Subtractive methodNRNRNR
2012Grandi T35Implants immediately loaded and restored using provisional abutments later replaced by custom-made abutments2850.3 (39–60)14FixedImmediately nonocclusally loadedJDEvolution (JDental Care S.r.l., Modena, Italy)Subtractive methodNRNRNR
2012Grandi T36Immediately nonocclusally loaded implants8151.8 (39–65)40FixedImmediately nonocclusally loadedJDEvolution (JDental Care S.r.l., Modena, Italy)Subtractive methodNRNRNone
2012Grandi T36Early-loaded implants8055.3 (43–65)40FixedEarly loaded (>2 days to <3 months)JDEvolution (JDental Care S.r.l., Modena, Italy)Subtractive methodNRNRNone
2014Grandi T38Immediately loaded single implants using a definitive abutment1256 (39–70)12FixedImmediately nonocclusally loadedJDEvolution (JDental Care S.r.l., Modena, Italy)Subtractive methodNRNRPeriimplant mucositis, abutment screw loosening (total: 2)
2014Grandi T38Immediately loaded single implants using a provisional abutment1357.08 (43–74)13FixedImmediately nonocclusally loadedJDEvolution (JDental Care S.r.l., Modena, Italy)Subtractive methodNRNR
2005Horwitz J29Chlorhexidine mouthwash2857.27 (NR)15FixedConventionally loaded (>3 months)Osseotite TG (Biomet3i, Palm Beach Gardens, USA)Subtractive methodNRNRNR
2005Horwitz J29Amine fluoride/stannous fluoride mouthwash3351.83 (NR)18FixedConventionally loaded (>3 months)Osseotite TG (Biomet3i, Palm Beach Gardens, USA)Subtractive methodNRNRNR
2013Kim YK20Osstem TSIII HA Implants immediately loaded5251.6 (NR)26FixedImmediately loaded (<48 hrs)Osstem TSIII HA (Osstem Implant Co., Seoul, Korea)Subtractive method98.1%NRSevere marginal bone loss (total: 2)
2013Kim YK20Zimmer TSV Implants immediately loaded4849.6 (NR)24FixedImmediately loaded (<48 hrs)TSV (Zimmer Dental, Carlsbad, USA)Subtractive method97.9%NR
2014Maryod WH16Immediately loaded mini-implants supporting mandibular overdentures7263.4 (NR)18RemovableImmediately loaded (<48 hrs)MDI (3M ESPE, Seefeld, Germany)Subtractive methodNRNRPain and mobility, with and without suppuration
2014Maryod WH16Early-loaded mini-implants supporting mandibular overdentures7264.8 (NR)18RemovableEarly loaded (>2 days to <3 months)MDI (3M ESPE, Seefeld, Germany)Subtractive methodNRNR
2014Meloni SM39Platform-switching implants: split mouth1848 (28–70)18FixedConventionally loaded (>3 months)Nobel Replace Tapered Groovy,(Nobel Biocare AB, Goteborg, Sweden)Subtractive and additive methodNRNRPeriimplant mucosal inflammation (total: 1)
2014Meloni SM39Regular platform implants: split mouth1848 (28–70)18FixedConventionally loaded (>3 months)Nobel Replace Tapered Groovy,(Nobel Biocare AB, Goteborg, Sweden)Subtractive and additive methodNRNR
2015Meloni SM43Socket sealing with epithelial connective tissue graft1549.7 (NR)15FixedConventionally loaded (>3 months)Nobel Replace (Nobel Biocare AB, Goteborg, Sweden)Subtractive and additive methodNRNRNone
2015Meloni SM43Socket sealing with porcine collagen matrix1546.8 (NR)15FixedConventionally loaded (>3 months)Nobel Replace (Nobel Biocare AB, Goteborg, Sweden)Subtractive and additive methodNRNRNone
2015Merli M40Bone mineral of bovine origin (Bio-Oss, Geistlich Bio- materials AG, Wolhusen, Switzerland) and collagen porcine membranes (Bio-Gide, Geistlich Biomaterials AG, Wolhusen, Switzerland)3256 (31–76)25FixedConventionally loaded (>3 months)Element RC Inicell Implants (Thommen Medical AG, Grenchen, Switzerland)Combination of subtractive metodsNRNRDehiscence of the mucosa, presence of purulent exsudate, tingling sensation and hyposensitivity (for both groups)
2015Merli M40Synthetic resorbable bone graft substitute (Ceros TCP, Thommen Medical AG, Grenchen, Switzerland) and porcine pericardium collagen membranes (Jason, Bottis AG, Bettlach, Switzerland)2953.4 (30–76)25FixedConventionally loaded (>3 months)Element RC Inicell Implants (Thommen Medical AG, Grenchen, Switzerland)Combination of subtractive methodsNRNR
2001Paolantonio M19Implant placed in a fresh extraction socket: maxilla, split mouth2441 (24–66)48FixedImmediately nonocclusally loadedTitanium plasma-sprayed solid screwed implants (PHI, Legnano, Italy)Additive methodNRNRNone
2001Paolantonio M19Implant placed in a fresh extraction socket: mandible, split mouth2441 (24–66)48FixedImmediately nonocclusally loadedTitanium plasma-sprayed solid screwed implants (PHI, Legnano, Italy)Additive methodNRNRNone
2001Paolantonio M19Implant placed contralateral in a mature bone: maxilla, split mouth2441 (24–66)48FixedImmediately nonocclusally loadedTitanium plasma-sprayed solid screwed implants (PHI, Legnano, Italy)Additive methodNRNRNone
2001Paolantonio M19Implant placed contralateral in a mature bone: mandible, split mouth2441 (24–66)48FixedImmediately nonocclusally loadedTitanium plasma-sprayed solid screwed implants (PHI, Legnano, Italy)Additive methodNRNRNone
2010Park JC31Nonsubmerged dental implants (Osstem SSII Implant System)3649.5 (NR)28FixedConventionally loaded (>3 months)Osstem SSII Implant System (Osstem Implant Co., Seoul, Korea)Subtractive method100%NRSevere marginal bone loss due to inflammation (total: 2)
2010Park JC31Nonsubmerged dental implants (Standard Straumann Dental Implant System)3946.84 (NR)28FixedConventionally loaded (>3 months)Standard Straumann Dental Implant System (Straumann AG, Basel, Switzerland)Combination of subtractive methods100%NR
2011Pieri F33Abutments with morse taper connection and a platform switch2045.8 (26–67)20FixedImmediately nonocclusally loadedSamo Smiler System (Samo Biomedica SpA, Cadriano, Italy)Additive method94.7%NRAbscess associated with a fistula, abutment screw loosening, fracture of the provisional crown (2 prosthetic, 1 biological)
2011Pieri F33Conventional abutments with an internal connection and a matching diameter2046.6 (32–65)20FixedImmediately nonocclusally loadedSamo Smiler System (Samo Biomedica SpA, Cadriano, Italy)Additive method100%NR
2016Schincaglia GP17Immediately loaded implants supporting a locator-retained mandibular overdenture3066.6 (53–79)15RemovableImmediately loaded (<48 hrs)OsseoSpeed (Astra Tech AB, Molndal, Sweden)Subtractive and additive methodNRNRDenture fractures, insert change, abutment loosening, denture adjustment
2016Schincaglia GP17Delayed loaded implants supporting a locator-retained mandibular overdenture3066.2 (57–85)15RemovableEarly loaded (>2 days to <3 months)OsseoSpeed (Astra Tech AB, Molndal, Sweden)Subtractive and additive methodNRNR
2011Tallarico M32One-stage-early-loaded implants3846.71 (26–76)29FixedEarly loaded (>2 days to <3 months)TiUnite Branemark System Implants (41 MKIII Groovy or Nobel 48 Speedy Groovy) (Nobel Biocare AB, Goteborg, Sweden)Subtractive and additive methodNRNRMobility without pain and swelling (total: 2)
2011Tallarico M32Two-stage early-loaded implants5148.39 (27–65)18FixedEarly loaded (>2 days to <3 months)TiUnite Branemark System Implants (41 MKIII Groovy or Nobel 48 Speedy Groovy) (Nobel Biocare AB, Goteborg, Sweden)Subtractive and additive methodNRNR
2012Vandeweghe S34Within comparison of platform-switching implants: switch1557 (32–75)15FixedConventionally loaded (>3 months)Max (Southern Implants, Irene, South Africa)Combination of subtractive methodsNRNRNR
2012Vandeweghe S34Within comparison of platform-switching implants: nonswitch1557 (32–75)15FixedConventionally loaded (>3 months)Max (Southern Implants, Irene, South Africa)Combination of subtractive methodsNRNRNR

Note: The article was published in Int J Oral Maxillofac Surg, Sommer M, Zimmermann J, Grize L, Stubinger S, Marginal bone loss one year after implantation – a systematic review for different loading protocols, Copyright Elsevier 2019.13

Abbreviation: NR, not reported.

List of selected studies13 Note: The article was published in Int J Oral Maxillofac Surg, Sommer M, Zimmermann J, Grize L, Stubinger S, Marginal bone loss one year after implantation – a systematic review for different loading protocols, Copyright Elsevier 2019.13 Abbreviation: NR, not reported. Alsabeeha et al15 estimated the success rate of the different implant systems on removable restorations. Overdentures connected by Southern Regular Implants (Southern Implants, Irene, South Africa) had the lowest implant success rate of 75% and Neoss Regular (Neoss Ltd., Harrogate, UK) and Southern Wide Implants (Southern Implants, Irene, South Africa) reached 100%. Concerning the different attachment types, overdentures with large ball attachment had the highest success rate of 83.3%, followed by overdentures with locator, 66.7%, and overdentures with standard ball attachment, 63.6%. The estimated implant success rates for the fixed restorations range between 94.7%33 and 100%.31,33 None of the authors mentioned the prosthesis success rate concerning fixed restorations. There are also biological and prosthetic complications listed. The most often mentioned complications concerning the biological tissue were severe MBL and periimplant mucositis. Prosthetic complications included abutment screw loosening and fracture of the restoration. Three randomized controlled clinical studies analyzed the MBL of implants which serve for better retention of overdentures. These results are illustrated in Table 2. All of them conducted examinations in the lower jaw. Alsabeeha et al15 placed one mini implant (Southern Implants (Southern Implants, Irene, South Africa), or Neoss Ltd. (Neoss Ltd., Harrogate, UK)) per patient for supporting the mandibular overdenture, while for the same treatment Maryod et al16 used four mini implants (3M ESPE, Seefeld, Germany). Schincaglia et al17 tested two OsseoSpeed Implants (AstraTech AB, Molndal, Sweden) per patient. Each study dealt with different types of implant surfaces: Alsabeeha et al15 decided to insert implants with a combination of subtractive methods (Southern Implants (Southern Implants, Irene, South Africa) [abraded rough surface of rutile titanium] and Neoss Ltd. (Neoss Ltd., Harrogate, UK) [sand-blasted and acid-etched and not a clearly described company-specific treatment]), the subtractive implant surface (blasted) was checked by Maryod et al,16 the OsseoSpeed Implants (OsseoSpeed, AstraTech AB, Molndal, Sweden) appearing in the study of Schincaglia et al17 were made of a combination of subtractive and additive techniques. Alsabeeha et al15 divided the patients into three equal groups: every group received a different type of implant and attachment system, but all the implants were connected to the overdenture also using the early loading protocol. Southern 8-mm-wide Implant and large ball attachments showed the best results with a measurement of MBL 0.13 mm. Neoss Regular Implants (Neoss Ltd., Harrogate, UK) and locator attachments had an MBL of 0.23 mm. The group with the Southern Regular Implants and standard ball attachments had the lowest survival rate of 90.9%, but an MBL of only 0.2 mm. The other two studies compared the immediate and early loading protocol. The groups with the immediate-loaded implants had a lower survival rate ranging between 91.7% and 93%. The MBL of overdentures loaded immediately by Maryod et al16 showed a higher MBL compared to the early loaded in this study, 1.03 mm±0.61 mm versus 0.93 mm±0.52 mm. In comparison, in the study of Schincaglia et al,17 the results were even better, 0.25 mm±0.5 mm versus 0.54 mm±0.5 mm. Figure 2 shows the Forest plot on the MBL around implants supporting removable restorations a year after implantation. The estimate for the mean MBL was 0.476 mm (95% CI: −0.305 to 1.258), and heterogeneity was not significant (p=0.714). The Egger’s test for freedom of publication bias had a p>0.1 (p=0.252). It was not possible to quantify the association between 1-year implant survival and MBL because only 3 studies were available to perform the metaregressions.
Table 2

Selected studies on removable restorations

YearFirst authorControl/test groupNumber of implantsImplant surfaceSurvival rate after 1 year (%)Mean bone loss (mm)SD (mm)
2011Alsabeeha NH15Southern Regular Implants and standard ball attachment12Combination of subtractive methods90.90.20.4
2011Alsabeeha NH15Southern 8-mm-wide Implants and large ball attachment12Combination of subtractive methods1000.130.35
2011Alsabeeha NH15Neoss Regular Implants and locator attachment12Combination of subtractive methods1000.230.44
2014Maryod WH16Immediately loaded mini-implants supporting mandibular overdentures72Subtractive method91.71.030.61
2014Maryod WH16Early-loaded mini-implants supporting mandibular overdentures72Subtractive method96.70.930.52
2016Schincaglia GP17Immediately loaded implants supporting a locator-retained mandibular overdenture30Subtractive and additive method930.250.5
2016Schincaglia GP17Delayed loaded implants supporting a locator-retained mandibular overdenture30Subtractive and additive method1000.540.5

Note: †Parameter for studies reporting several groups were summarized.

Figure 2

Meta-analysis of the mean marginal bone loss (MBL) 1 year after implantation for removable restorations.

Abbreviations: Mean, mean difference; dl, DerSimonian–Laird random-effects model.

Selected studies on removable restorations Note: †Parameter for studies reporting several groups were summarized. Meta-analysis of the mean marginal bone loss (MBL) 1 year after implantation for removable restorations. Abbreviations: Mean, mean difference; dl, DerSimonian–Laird random-effects model. The 19 randomized controlled clinical studies dealing with the fixed restored implants are shown in Table 3. The study of Cooper et al,18 dealing with the replacement of single teeth by implants in the anterior maxilla, showed the lowest survival rate of 85.7%. Implants inserted in the trial of Paolantonio et al19 reached the maximum MBL of 1.37 mm. In contrast to this high value, the lowest MBL was found by Kim et al20 dealing with two consecutive implants restored with splinted crowns. Conspicuously, the study of Cooper et al21 measured a bone gain of 1.3 mm. The authors did not mention the possible reasons for this deviation. Figure 3 shows the Forest plot on the MBL around implants supporting fixed restorations a year after implantation. The estimate for the mean MBL was 0.459 mm (95% CI: 0.325–0.593), and heterogeneity was not significant (p=0.955). The Egger’s test for freedom of publication bias had a p>0.1 (p=0.302). A decrease of −0.083% (95% CI: −0.179 to 0.013 p=0.086) in 1-year implant survival per an increase of 1 mm in MBL was observed in fixed restorations.
Table 3

Selected studies on fixed restorations

YearFirst authorControl/test groupNumber of implantsImplant surfaceSurvival rate after 1 year (%)Mean bone loss (mm)SD (mm)
2001Paolantonio M19Implant placed in a fresh extraction socket: maxilla, split mouth24Additive method1001.370.5
2001Paolantonio M19Implant placed in a fresh extraction socket: mandible, split mouth24Additive method1001.180.5
2001Paolantonio M19Implant placed contralateral in a mature bone: maxilla, split mouth24Additive method1001.180.3
2001Paolantonio M19Implant placed contralateral in a mature bone: mandible, split mouth24Additive method1001.120.4
2005Horwitz J29Chlorhexidine mouthwash28Subtractive method92.91.060.13
2005Horwitz J29Amine fluoride/stannous fluoride mouthwash33Subtractive method1001.270.25
2008Cannizzaro G30Flapless placed implants immediately loaded with full-arch prostheses90Subtractive method98.90.550.22
2008Cannizzaro G30Flapless placed implants early loaded at 2 months with full-arch prostheses87Subtractive method96.70.620.25
2010Park JC31Nonsubmerged dental implants (Osstem SSII Implant system)36Subtractive method1000.790.42
2010Park JC31Nonsubmerged dental implants (Standard Straumann Dental Implant System)39Combination of subtractive methods93.91.070.46
2010Cooper LF21Single implants placed in fresh extraction sockets58Subtractive and additive method94.5−1.302.52
2010Cooper LF21Single implants placed in healed ridges65Subtractive and additive method98.30.41.43
2011Tallarico M32One-stage early-loaded implants38Subtractive and additive method94.70.860.37
2011Tallarico M32Two-stage early-loaded implants51Subtractive and additive method1000.770.28
2011Pieri F33Abutments with morse taper connection and a platform switch20Additive method94.70.190.17
2011Pieri F33Conventional abutments with an internal connection and a matching diameter20Additive method1000.490.25
2012Grandi T35Implants immediately loaded and restored using definitive abutments28Subtractive method1000.090.03
2012Grandi T35Implants immediately loaded and restored using provisional abutments later replaced by custom-made abutments28Subtractive method1000.440.03
2012Grandi T36Immediately nonocclusally loaded implants81Subtractive method1000.420.01
2012Grandi T36Early-loaded implants80Subtractive method1000.470.01
2012Vandeweghe S34Within comparison of platform-switching implants: switch15Combination of subtractive methods1000.660.47
2012Vandeweghe S34Within comparison of platform-switching implants: nonswitch15Combination of subtractive methods1000.940.42
2013Cannizzaro G372 implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screw-retained cross-arch prostheses60Subtractive and additive method/subtractive method1000.740.54
2013Cannizzaro G374 implants placed flapless in fully edentulous mandibles and immediately restored with metal-resin screw-retained cross-arch prostheses120Subtractive and additive method/subtractive method1000.580.38
2013Kim YK20Osstem TSIII HA Implants immediately loaded52Subtractive method1000.050.67
2013Kim YK20Zimmer TSV Implants immediately loaded48Subtractive method1000.630.61
2014Grandi T38Immediately loaded single implants using a definitive abutment12Subtractive method1000.110.06
2014Grandi T38Immediately loaded single implants using a provisional abutment13Subtractive method1000.580.11
2014Meloni SM39Platform-switching implants: split mouth18Subtractive and additive method1000.50.27
2014Meloni SM39Regular platform implants: split mouth18Subtractive and additive method1000.560.22
2015Cooper LF18Conical implant–abutment interface53Subtractive and additive method1000.220.28
2015Cooper LF18Flat to flat implant–abutment interface53Subtractive and additive method85.71.20.64
2015Cooper LF18Platform-switched implant–abutment interface50Subtractive and additive method86.41.321.01
2015Esposito M42Implant surface roughened with sandblasting and double etching137Combination of subtractive methods1000.640.2
2015Esposito M42Machined, turned implant surface163Machined surface98.80.680.23
2015Cannizzaro G41Prostheses supported by supershort (5 mm) implants: maxilla90Subtractive and additive method97.80.150.04
2015Cannizzaro G41Prostheses supported by supershort (5 mm) implants: mandible60Subtractive and additive method1000.080.03
2015Cannizzaro G41Prostheses supported by long (11.5 mm) implants: maxilla90Subtractive and additive method1000.620.12
2015Cannizzaro G41Prostheses supported by long (11.5 mm) implants: mandible60Subtractive and additive method98.30.510.1
2015Meloni SM43Socket sealing with epithelial connective tissue graft15Subtractive and additive method1000.90.18
2015Meloni SM43Socket sealing with porcine collagen matrix15Subtractive and additive method1000.840.21
2015Merli M40Bone mineral of bovine origin (Bio-Oss, Geistlich Bio- materials AG, Wolhusen, Switzerland) and collagen porcine membranes (Bio-Gide, Geistlich Biomaterials AG, Wolhusen, Switzerland)32Combination of subtractive methods1000.770.36
2015Merli M40Synthetic resorbable bone graft substitute (Ceros TCP, Thommen Medical AG, Grenchen, Switzerland) and porcine pericardium collagen membranes (Jason, Bottis AG, Bettlach, Switzerland)29Combination of subtractive methods1000.540.45

Note: †Parameter for studies reporting several groups were summarized.

Figure 3

Meta-analysis of the mean marginal bone loss (MBL) 1 year after implantation for fixed restorations.

Abbreviations: Mean, mean difference; dl, DerSimonian–Laird random-effects model.

Selected studies on fixed restorations Note: †Parameter for studies reporting several groups were summarized. Meta-analysis of the mean marginal bone loss (MBL) 1 year after implantation for fixed restorations. Abbreviations: Mean, mean difference; dl, DerSimonian–Laird random-effects model. The IQR for the 1-year implant survival reported in the considered studies was 97.0–100.0% with a median of 99.2%. The overall MBL estimates for the fixed and removable restorations did not statistically differ (0.363 mm; 95% CI: −0.319 to −1.044; p=0.279).

Discussion

Patients suffering from partial or total edentulism benefit from the rehabilitation of the situation by inserting dental implants. This process shows a high satisfaction.22 Several prosthetic reconstructions including either fixed or removable approaches are possible.23 While composing this systematic review including a meta-analysis, we only searched for randomized controlled clinical trials in which the MBL was measured 1 year after implantation. Furthermore, we wanted to assess if there is a difference concerning the MBL between the two prosthetic processes. The meta-analysis showed an overall estimated MBL for the removable prostheses of 0.476 mm and for the fixed restorations of 0.459 mm. There is very little difference between these two values, which means that both prosthetic procedures lead to <0.5 mm MBL 1 year after implantation. We noticed that the randomized controlled clinical studies in this review assessed many different issues such as different implant lengths, platform-matching/platform-switching implants, different loading protocols, submerged/nonsubmerged implants, different ball attachments and abutment connections. In conclusion, the selected randomized controlled clinical studies in this review did not directly compare MBL around implants of removable and fixed prostheses. Regarding the studies dealing with the MBL of removable prostheses, two of three trials compared the immediate and early loading. In both controlled clinical trials, the survival rate of the immediate-loading protocol was lower. The MBL of the immediate-loading protocol measured by Schincaglia et al17 was statistically significant (p-value <0.02) lower than the value of the early loading protocol. Comparably, Maryod et al16 proved a statistically significant (p-value <0.011) higher MBL after 6 months of the immediate-loaded implants. But after 6 months, there was no statistically significant difference concerning MBL between the two loading protocols. To come to a decision which might be the most advantageous approach for patients in need of implant-supported overdentures, Ma et al24 compared different loading protocols, surfaces and attachment systems for mandibular two-implant overdentures. They came to the conclusion that different attachment systems do not significantly influence the MBL. Furthermore, machined implant surfaces showed statistically significant (p-value <0.05) more MBL than subtractive methods. For the subtractive methods, they used Southern,5 Straumann (Straumann Group, Basel, Switzerland) and Steri-Oss (Nobel Biocare, Goteborg, Sweden) Implants. In our review, we included one study of Alsabeeha et al15 where they inserted Neoss Implants (Neoss Ltd., Harrogate, UK) between Southern Implants (Southern Implants, Irene, South Africa). Both came to similar results concerning MBL of Southern Implants. Ma et al24 lost 0.16 mm and Alsabeeha et al15 lost 0.13 mm in one group and 0.2 mm in the other group.  MBL was statistically significantly higher (p-value <0.05) for implants loaded 2 weeks after insertion in comparison to the implants loaded 12 weeks after implantation in the study of Ma et al.24 The difference of MBL of implants loaded 6 or 12 weeks after implantation was not statistically significant (p-value >0.05). Concerning the implant success rate, they had comparable values to Alsabeeha et al.15 The measurements stayed constant after 1 year until 10 years after loading. To evaluate if there is a difference between overdentures supported by one or two implants, Tavakolizadeh et al25 developed a study design on this topic. Twenty unsatisfied patients received either one or two interforaminal implants. After implant surgery, implants were immediately loaded. The outcome of the MBL was 0.6 mm±0.67 mm for one implant group and 0.6 mm±0.51 mm for the other. These results as well as those of Cordioli et al26 correlate with our results. To compare this review, for the fixed prostheses, we calculated a mean MBL of 0.459 mm considering no subgroups of the fixed prostheses. The review of Firme et al27 describes the MBL around implants supporting single fixed prostheses and multiple-unit screw-retained prostheses. They included 17 clinical trials, 7 were related to single-implant prostheses and 10 to multiple-unit screw-retained prostheses. The mean MBL and the implant success rate for the single-implant prostheses was 0.58 mm and 100%, respectively, and for the multiple-unit screw-retained prostheses the respective values were 0.9 mm and 89.1–98.9%. They showed no statistical difference (p-value >0.05) between the two types of prostheses. In this case, it has to be considered that it was not clear when the follow-up was done, 1 year after implantation or 1 year after loading. The long-term study of Lai et al28 showed less MBL. The authors analyzed 231 short dental implants supporting single crowns in 168 patients using a follow-up of 1, 5 and 10 years. The MBL measured 1 year after implantation was 0.55 mm±0.45 mm. This value is comparable to our results. During the time period of 1–5 years and 5–10 years, the MBL slightly increased, with the values being 0.05 mm±0.10 mm and 0.03 mm±0.14 mm, respectively. These results indicate that most bone remodeling occurs 1 year after implantation. This systematic review and meta-analysis indicate that both the implants with fixed and with removable restorations lead to low respectively comparable MBL. However, there is a lack of clinical trials which compare these two types of restoration to each other. Further information in studies about the implant and prosthesis success rates are needed to make a clear statement. Other factors may influence the marginal bone more than the type of restoration, namely the loading protocol, or the implant surface. There is a need for further clinical trials to find the factors which lead to MBL in fixed and removable restorations supported by implants.
  41 in total

1.  The glossary of prosthodontic terms.

Authors: 
Journal:  J Prosthet Dent       Date:  1999-01       Impact factor: 3.426

Review 2.  A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years.

Authors:  Tord Berglundh; Leif Persson; Björn Klinge
Journal:  J Clin Periodontol       Date:  2002       Impact factor: 8.728

3.  A survey of the use of mandibular implant overdentures in 10 countries.

Authors:  Gunnar E Carlsson; Mats Kronström; Cees de Baat; Marco Cune; David Davis; Pavlos Garefis; Seong Joo Heo; Asbjørn Jokstad; Masarou Matsuura; Timo Närhi; Richard Ow; Argiris Pissiotis; Hironobu Sato; George A Zarb
Journal:  Int J Prosthodont       Date:  2004 Mar-Apr       Impact factor: 1.681

4.  Immediate implantation in fresh extraction sockets. A controlled clinical and histological study in man.

Authors:  M Paolantonio; M Dolci; A Scarano; D d'Archivio; G di Placido; V Tumini; A Piattelli
Journal:  J Periodontol       Date:  2001-11       Impact factor: 6.993

Review 5.  Management of the edentulous patient.

Authors:  R D Mericske-Stern; T D Taylor; U Belser
Journal:  Clin Oral Implants Res       Date:  2000       Impact factor: 5.977

6.  Amine fluoride/stannous fluoride and chlorhexidine mouthwashes as adjuncts to single-stage dental implants: a comparative study.

Authors:  Jacob Horwitz; Eli E Machtei; Otman Zuabi; Micha Peled
Journal:  J Periodontol       Date:  2005-03       Impact factor: 6.993

7.  Prosthetic aspects and patient satisfaction with two-implant-retained mandibular overdentures: a 10-year randomized clinical study.

Authors:  Ignace Naert; Ghada Alsaadi; Marc Quirynen
Journal:  Int J Prosthodont       Date:  2004 Jul-Aug       Impact factor: 1.681

Review 8.  Impact of implant support for mandibular dentures on satisfaction, oral and general health-related quality of life: a meta-analysis of randomized-controlled trials.

Authors:  Elham Emami; Guido Heydecke; Pierre H Rompré; Pierre de Grandmont; Jocelyne S Feine
Journal:  Clin Oral Implants Res       Date:  2009-06       Impact factor: 5.977

9.  Oral rehabilitation using Camlog screw-cylinder implants with a particle-blasted and acid-etched microstructured surface. Results from a prospective study with special consideration of short implants.

Authors:  Frank Peter Strietzel; Peter A Reichart
Journal:  Clin Oral Implants Res       Date:  2007-06-21       Impact factor: 5.977

Review 10.  Implantology and the severely resorbed edentulous mandible.

Authors:  C Stellingsma; A Vissink; H J A Meijer; C Kuiper; G M Raghoebar
Journal:  Crit Rev Oral Biol Med       Date:  2004-07-01
View more
  4 in total

1.  [Clinical observation of the curative effect after 5-year follow-up of single tooth implant-supported restorations in the posterior region].

Authors:  F Liang; M J Wu; L D Zou
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2021-10-18

2.  Bone remodeling around dental implants after 1-1.5 years of functional loading: A retrospective analysis of two-stage implants.

Authors:  Poyan Maghsoudi; Dagmar E Slot; Fridus G A van der Weijden
Journal:  Clin Exp Dent Res       Date:  2022-04-15

3.  Marginal Bone Loss around Implant-Retaining Overdentures versus Implant-Supported Fixed Prostheses 12-Month Follow-Up: A Retrospective Study.

Authors:  Odontuya Dorj; Chin-Kai Lin; Eisner Salamanca; Yu-Hwa Pan; Yi-Fan Wu; Yung-Szu Hsu; Jerry C-Y Lin; Hsi-Kuei Lin; Wei-Jen Chang
Journal:  Int J Environ Res Public Health       Date:  2022-02-03       Impact factor: 3.390

4.  Clinical Performance of Implant Crown Retained Removable Partial Dentures for Mandibular Edentulism-A Retrospective Study.

Authors:  Soo-Yeon Yoo; Seong-Kyun Kim; Seong-Joo Heo; Jai-Young Koak; Hye-Rin Jeon
Journal:  J Clin Med       Date:  2021-05-18       Impact factor: 4.241

  4 in total