The effects of implant composition on extensor tenosynovitis in a canine distal radius fracture model.

Stefano M Sinicropi1, Brian W Su, Frank J Raia, May Parisien, Robert J Strauch, Melvin P Rosenwasser.   

Abstract

PURPOSE: Dorsal plating of distal radius fractures with titanium plates has resulted in clinically observed tenosynovitis and tendon rupture. The goal of this study was to investigate whether titanium-based implants result in more extensor tendon inflammation than matched stainless-steel implants in a canine fracture model.
METHODS: An osteotomy was created in the distal radius of 18 beagles and fixed with 2.7-mm 4-hole plates composed of commercially pure titanium, titanium alloy (Ti-Al6-V4), or 316L stainless steel. Animals were killed at an average of 4 months. Tendon gliding was assessed by applying a force at the extensor musculotendinous junction and noting gliding. Histologic grading (mild, moderate, severe) was based on cellular hypertrophy, hyperplasia, and leukocytic infiltration.
RESULTS: Tendons glided freely in 100% stainless-steel specimens, 75% of titanium alloy, and 43% of commercially pure titanium groups. A severe inflammatory reaction was identified in 60% of the titanium alloy (Ti-A16-V4) group, 57% of the pure titanium group, and 0% of the stainless-steel group.
CONCLUSIONS: Dorsal plating of the canine radius with commercially pure titanium or titanium alloy implants produced a greater inflammatory peritendinous response than matched stainless-steel implants.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15781352     DOI: 10.1016/j.jhsa.2004.08.004

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  4 in total

1.  Impact of Design on Force between Flexor Tendons and Distal Radius Volar Plates.

Authors:  Katharine M Hinchcliff; Ido Volk; Xenia Ivanova; Sandra Taylor; Robert M Szabo
Journal:  J Wrist Surg       Date:  2019-03-25

2.  Titanium versus Stainless-Steel Plating in the Surgical Treatment of Distal Radius Fractures: A Randomized Trial.

Authors:  Sameer Shakir; Sanjay Naran; Mithun Neral; Ronit Wollstein
Journal:  J Hand Microsurg       Date:  2016-10-12

3.  Infection in fracture fixation: can we influence infection rates through implant design?

Authors:  T Fintan Moriarty; U Schlegel; S Perren; R Geoff Richards
Journal:  J Mater Sci Mater Med       Date:  2009-10-20       Impact factor: 3.896

4.  A systematic review of the use of titanium versus stainless steel implants for fracture fixation.

Authors:  Collin C Barber; Matthew Burnham; Ogaga Ojameruaye; Michael D McKee
Journal:  OTA Int       Date:  2021-08-18
  4 in total